  1. Micron-Level Actuator for Thermal-Fluid Control in Microchannels

    … jump boundary conditions encountered in micron-level devices. Compressibility effects are also taken into account and modeled through the compressible flow solver. The utility of synthetic jet actuators for manipulating fluid flows has been shown for mostly macro- and mini-scale …

    odu Repository record for Micron-Level Actuator for Thermal-Fluid Control in Microchannels (opens in a new tab)

  2. Contribution of Collagen Type I to the Mechanical Properties of Myocardial Tissues at the Micron Level

    … capacity during diastole. At an organ-wide level, this has been measured and modeled in many ways. At the tissue level, the mechanical properties have been evaluated using techniques such as bi-axial stretching. While very effective at approximating bulk properties, this cannot differentiate …

    clemson Repository record for Contribution of Collagen Type I to the Mechanical Properties of Myocardial Tissues at the Micron Level (opens in a new tab)

  3. Non-invasive characterization of bone tissue and modeling of bone at micron and sub-micron levels

    … spanning from a nanoscale to a whole bone level. We focus on modeling bone at two structural length scales, namely a micron level and a sub-micron level, and perform a feasibility study of using ultrasound to detect bone growth in a limb regeneration project. At the sub-micron level, bone …

    uiuc Repository record for Non-invasive characterization of bone tissue and modeling of bone at micron and sub-micron levels (opens in a new tab)

  4. HYBRID COMPUTATIONAL AND HARDWARE METHODS FOR OPTICAL COHERENCE TOMOGRAPHY

    … noninvasiveoptical biopsy of tissue with micron level resolution via low coherence interferometry. Recently, as the demand is growing for high throughput and deep imaging, OCT seems to become a good candidate to accomplish these tasks. The coherence gate with heterodyning detection achieve …

    cornell Repository record for HYBRID COMPUTATIONAL AND HARDWARE METHODS FOR OPTICAL COHERENCE TOMOGRAPHY (opens in a new tab)

  5. Improved Synthetic Methods for Patchy Particles

    … for patchy particles, especially at the sub-micron level, are still a challenge and an active area of research. This work presents a novel synthesis route for making patchy particles at the sub-micron level that involves the use of capillary condensation. Colloidal silica particles of various …

    tamu Repository record for Improved Synthetic Methods for Patchy Particles (opens in a new tab)

  6. The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds

    … the ability of the stripline BPM to resolve micron-level position osets. The experiments agree that the worst ILC pair backgrounds degrade the resolution by less than 8.5 nm (95% confidence level). It is concluded that micron-level resolution will not be aected by the ILC pair backgrounds. …

    oxford Repository record for The Interaction Point Collision Feedback System at the International Linear Collider and its sensitivity to expected electromagnetic backgrounds (opens in a new tab)

  7. Nanomechanics of plasma polymerised siloxane thin films: effects of substrate materials and deposition parameters on the nanomechanical properties

    … properties of thin films at the nano/sub micron level is important for rational selection of coatings for critical applications. In this thesis, the nanomechanical properties of plasma polymerised thin films were investigated in detail. The principal aim of the present work is to gain a …

    adelaide Repository record for Nanomechanics of plasma polymerised siloxane thin films: effects of substrate materials and deposition parameters on the nanomechanical properties (opens in a new tab)

  8. Laser Assisted Mechanical Micromachining of Hard-to-Machine Materials

    … three-dimensional free-form surfaces to sub-micron level precision and micron level accuracies in a wide range of materials including common engineering alloys. However, certain factors limit the types of workpiece materials that can be processed using mechanical micromachining methods. For …

    gatech Repository record for Laser Assisted Mechanical Micromachining of Hard-to-Machine Materials (opens in a new tab)

  9. Efficient Power Management for Heterogeneous Multi-Core Architectures

    … Semiconductor (CMOS) scaling at deep sub-micron level has resulted in increased power density in microprocessor, which forced the computing systems to move in the direction of parallel architectures with homogeneous multi-cores. However, the emergence of dynamic and diverse workloads …

    nus Repository record for Efficient Power Management for Heterogeneous Multi-Core Architectures (opens in a new tab) Download file for Efficient Power Management for Heterogeneous Multi-Core Architectures (opens in a new tab)

  10. Corrosion Investigation of Structural Transition Joints Through Scanning Electrochemical Microscopy and the Characterization of High-Temperature Coatings at Different Temperatures

    … paired with an XYZ positioning system capable of micron-level movements. This study investigates the corrosion behavior of structural transition joint clad material that contains steel, pure aluminum, and an aluminum alloy blast welded into a single joint. This study will characterize the …

    ndsu Repository record for Corrosion Investigation of Structural Transition Joints Through Scanning Electrochemical Microscopy and the Characterization of High-Temperature Coatings at Different Temperatures (opens in a new tab)

  11. Polymeric Microsensors for Intraoperative Contact Pressure Measurement

    … microfabrication processing for micron-level resolution.</p> <p>An array of sensors for real-time measurement of pressure profiles is the long-term goal of this research. A custom design using capacitive-based sensors is an excellent selection for such measurement, giving high …

    utk-theses Repository record for Polymeric Microsensors for Intraoperative Contact Pressure Measurement (opens in a new tab)

  12. An Investigation of the Microstructure and Properties of a Cryogenically Mechanically Alloyed Polycarbonate-Poly(Ether Ether Ketone) System

    … processed for 10 hours were shown to have a sub-micron level two-phase microstructure. These powders were processed into testable coupons using a mini ram-injection molder; microstructure and bulk mechanical properties of the coupons were investigated as a function of mechanical alloying and …

    vt Repository record for An Investigation of the Microstructure and Properties of a Cryogenically Mechanically Alloyed Polycarbonate-Poly(Ether Ether Ketone) System (opens in a new tab)

  13. REALIZATION OF A CANINE POSITIONING DEVICE FOR IN SITU PROSTATE PHASE CONTRAST – COMPUTED TOMOGRAPHY IMAGING

    … This device is currently being used to collect micron-level resolution PC-CT reconstructions of canine cadaver prostates. This thesis lays the ground work for canine imaging on the BMIT – ID beamline at the CLS. The design and implementation of the device are described, along with the issues …

    sask Repository record for REALIZATION OF A CANINE POSITIONING DEVICE FOR IN SITU PROSTATE PHASE CONTRAST – COMPUTED TOMOGRAPHY IMAGING (opens in a new tab)

  14. Integration of optical structures with chiral nanocellulose films

    … a good registration of features size down to sub-micron level with uniformity across large area on the film surface. As a result, a combination of more accurate and sharper structural color, light focusing capability as well as enhanced circular dichroism is observed, indicating great potential in …

    gatech Repository record for Integration of optical structures with chiral nanocellulose films (opens in a new tab)

  15. Infrared microspectroscopy of focally elevated creatine in brain tissue from amyloid precursor protein (APP) transgenic mice

    … of untreated, flash frozen tissue samples, at micron level spatial resolution, and was used in this study to examine creatine deposits in the Alzheimer’s diseased brain. Creatine is central to cellular energetics and plays an important role in proper brain function. The hippocampi of 7 pairs of …

    manitoba Repository record for Infrared microspectroscopy of focally elevated creatine in brain tissue from amyloid precursor protein (APP) transgenic mice (opens in a new tab)

  16. A high accuracy CMOS camera based 3D optical tracking system design

    … achieve high measurement rate up to 10 kHz and micron level accuracy. Target location algorithms are widely studied. However, to the best of the author’s knowledge, no experimental comparison of these different algorithms in 3D optical tracking systems was found in the literature. In addition, …

    ubc Repository record for A high accuracy CMOS camera based 3D optical tracking system design (opens in a new tab) Download PDF for A high accuracy CMOS camera based 3D optical tracking system design (opens in a new tab)

  17. Light Pipe Optical Characterization

    … (FLICE), freeform fused silica structures having micron level features are becoming increasingly more feasible to physically realize. One application of this technology is the creation of light pipes for solar concentrators, as fused silica offers significantly higher transmission and damage …

    tamu Repository record for Light Pipe Optical Characterization (opens in a new tab)

  18. Mechanical Properties of Bone Due to SOST Expression: Nanoindentation Assessment of Murine Femurs

    … were embedded in epoxy and polished to a 0.05 micron level before indentation. Results showed significant difference amongst the treatment group effects for maximum load, hardness and elastic modulus. SOST KO mice had significantly higher values for these properties in comparison to the …

    calpoly Repository record for Mechanical Properties of Bone Due to SOST Expression: Nanoindentation Assessment of Murine Femurs (opens in a new tab)

  19. Development of a high resolution 3D Computed Tomography system: data acquisition, reconstruction and visualization

    … years, more and more interest is focused on micron-level features. A consequence is the rapidly growing data volume of both original CT data and 3D images. This data handling capability at both data acquisition stage and in the processing part is largely limited by computer power available, …