Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 7 of 7 for “"Microphone calibration"”

  1. Three-dimensional broadband intensity probe for measuring acoustical parameters

    … (200 Hz – 6.5 kHz) three-dimensional seven-microphone intensity probe system is developed to measure the sound intensity, and total energy density in different acoustical environments. Limitations of most commercial intensity probes in measuring the three-dimensional intensity for a …

    texas Repository record for Three-dimensional broadband intensity probe for measuring acoustical parameters (opens in a new tab)

  2. Transmission loss of silencers with flow from a flow-impedance tube using burst signals

    … obtained. Also discussed in this study are (1) microphone calibration, (2) time domain editing functions, and (3) hydraulic losses either to improve the accuracy or the capacity of the transmission loss setup in the presence of flow. Using the new experimental setup, the effect of flow on …

    ohiolink Repository record for Transmission loss of silencers with flow from a flow-impedance tube using burst signals (opens in a new tab)

  3. Development of a Multiple Microphone Probe Calibrator

    … presents the theory, design, and validation of a microphone calibrator used to calibrate multiple microphones simultaneously. This work was done in conjunction with the development of an acoustic energy density probe, which was used to validate the calibrator. The probe uses multiple microphones …

    byu Repository record for Development of a Multiple Microphone Probe Calibrator (opens in a new tab)

  4. Relative Infrasound Calibration of Microphones with Application to Outdoor Vector Intensity Measurements

    … amplitude correction of 12.7 mm diameter, Type-1 microphones for three frequency bands, including within the infrasound regime, and its application to acoustic measurements. Previous data stem from acoustic intensity measurements using two-dimensional, four-microphone probes, which emphasized the …

    byu Repository record for Relative Infrasound Calibration of Microphones with Application to Outdoor Vector Intensity Measurements (opens in a new tab)

  5. Enabling Speech Applications using Ad Hoc Microphone Arrays

    Microphone arrays are central players in hands-free speech interface applications. The main duty of a microphone array is capturing distant-talking speech with high quality. A microphone array can acquire the desired speech signals selectively by leading the beampattern towards the desired speaker. …

    epfl Repository record for Enabling Speech Applications using Ad Hoc Microphone Arrays (opens in a new tab)

  6. Interférométrie à rétroaction optique pour la mesure acoustique et l'étalonnage de microphones

    … ainsi que son application à l'étalonnage de microphones. Cet interféromètre présente l'avantage d'être auto-aligné et moins encombrant que des interféromètres plus classiques comme le Mach-Zehnder ou encore le Vibromètre Laser Doppler (Laser Doppler Vibrometer, LDV). Les objectifs de cette …

    star-france Repository record for Interférométrie à rétroaction optique pour la mesure acoustique et l'étalonnage de microphones (opens in a new tab)