Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 37 for “"Microphysiological System"”.

  1. A HUMAN BRAIN MICROPHYSIOLOGICAL SYSTEM FOR THE STUDY OF PARKINSON’S DISEASE

    … of recapitulating human physiology in a microphysiological system that remains consistently healthy at its core as well as on its surface, and can be produced in abundance without compromising uniformity of structure, size, and shape. Using a relatively simple, easily reproducible model, …

    jhu Repository record for A HUMAN BRAIN MICROPHYSIOLOGICAL SYSTEM FOR THE STUDY OF PARKINSON’S DISEASE (opens in a new tab)

  2. Developing a Fibrotic Phenotype in a 3D Human Skeletal Muscle Microphysiological System

    … of skeletal muscle fibrosis on the vascular system, we integrated the fibrotic skeletal muscle with tissue engineered blood vessels. Treating myobundles with Transforming Growth Factor β1 (TGF-β1) reproduced key characteristics of fibrotic skeletal muscle including reduced contractile force, …

    duke Repository record for Developing a Fibrotic Phenotype in a 3D Human Skeletal Muscle Microphysiological System (opens in a new tab)

  3. IMSIS: an instrumented microphysiological system with integrated sensors for monitoring cellular metabolic activities

    … dissertation, an Instrumented Microphyiological System with Integrated Sensors (IMSIS) platform is presented. The IMSIS platform is supported by integrated bioelectronic circuits and a graphical user interface for easy user configuration and monitoring. The IMSIS platform currently incorporates …

    colostate Repository record for IMSIS: an instrumented microphysiological system with integrated sensors for monitoring cellular metabolic activities (opens in a new tab) Embargoed until 2026-12-20

  4. A microphysiological system for studying barrier health of live tissues in real time

    … various stimuli ex vivo. This thesis presents a microphysiological system capable of recording real-time barrier permeability of mouse gut tissues in a realistic physiological environment over extended durations. Key components of the microphysiological system include a microfluidic chamber …

    colostate Repository record for A microphysiological system for studying barrier health of live tissues in real time (opens in a new tab)

  5. STUDY OF EARLY ACUTE PHTHALATE EXPOSURE USING A 3D HUMAN IPSC-DERIVED BRAIN MICROPHYSIOLOGICAL SYSTEM

    … pluripotent stem cell (hiPSC)-derived 3D brain microphysiological system (bMPS). Phthalates (PAEs) are known ubiquitous EDCs with a pervasive presence in groundwater, maternal breast milk, and amniotic fluid. Di(2-ethylhexyl) phthalate (DEHP) and mono(2-ethylhexyl) phthalate (MEHP), known …

    jhu Repository record for STUDY OF EARLY ACUTE PHTHALATE EXPOSURE USING A 3D HUMAN IPSC-DERIVED BRAIN MICROPHYSIOLOGICAL SYSTEM (opens in a new tab)

  6. Application of a Renal Proximal Tubule Microphysiological System for Drug Safety Assessment and Disease Modeling

    … vitro assays, which can cause the drug screening systems to fail to accurately imitate drug behavior in humans. As such, 85% of molecules that enter clinical trials do not make it to market because of a failure to demonstrate their safety and/or efficacy. In recognition of these shortcomings, the …

    washington Repository record for Application of a Renal Proximal Tubule Microphysiological System for Drug Safety Assessment and Disease Modeling (opens in a new tab)

  7. Modeling the impact of fluid shear stress on virus infection using a vascular microphysiological system

    … our knowledge by offering complex, multiorgan systems to study infection. While static cell cultures use human cells and animal models possess FSS, there remains a need for platforms to simultaneously integrate both human cells and biomechanical forces of the vasculature. This dissertation …

    bu Repository record for Modeling the impact of fluid shear stress on virus infection using a vascular microphysiological system (opens in a new tab)

  8. Characterization of the long-term toxic response of proximal tubule epithelial cells in a microphysiological system

    … incidence of kidney disease. Organs-on-chips or microphysiological systems (MPS) are innovative microfluidic models to enhance our understanding of xenobiotic effects on kidney function. Previous studies from our group replicated toxic responses in kidney proximal tubule epithelial cells (PTECs); …

    washington Repository record for Characterization of the long-term toxic response of proximal tubule epithelial cells in a microphysiological system (opens in a new tab)

  9. Reproducibility and Robustness of PhysioMimix LC12, a Liver Microphysiological System, Under Varying Culture Conditions and Cell Type Combinations

    … methods to animal testing. One type of NAMs is microphysiological systems, or MPS. According to the US Food and Drug Administration, MPS are microscale cell culture platforms for in vitro modeling of functional features of a specific tissue or organ of human or animal origin that expose cells to …

    tamu Repository record for Reproducibility and Robustness of PhysioMimix LC12, a Liver Microphysiological System, Under Varying Culture Conditions and Cell Type Combinations (opens in a new tab)

  10. Reproducibility and Robustness of PhysioMimix LC12, a Liver Microphysiological System, Under Varying Culture Conditions and Cell Type Combinations

    … methods to animal testing. One type of NAMs is microphysiological systems, or MPS. According to the US Food and Drug Administration, MPS are microscale cell culture platforms for in vitro modeling of functional features of a specific tissue or organ of human or animal origin that expose cells to …

    tamu Repository record for Reproducibility and Robustness of PhysioMimix LC12, a Liver Microphysiological System, Under Varying Culture Conditions and Cell Type Combinations (opens in a new tab)

  11. Investigating flow-related effects of Chronic Kidney Disease on renal drug toxicity in a human-derived proximal tubule microphysiological system

    … toxicity in HRPTEC cultured in 3D in the Nortis microphysiological system. qPCR was used to evaluate differential gene expression of drug transporters, proximal tubule and stress markers in response to flow exposure and nutrient deprivation in 3D and 2D cultured HRPTEC, alongside LDH in the …

    chalmers Repository record for Investigating flow-related effects of Chronic Kidney Disease on renal drug toxicity in a human-derived proximal tubule microphysiological system (opens in a new tab)

  12. Development of a Liver-Kidney Dual Organ Microphysiological System for Predicting Organ-Organ Interactions in the Toxicity of Xenobiotics: Aristolochic Acid Nephrotoxicity as a proof of Principle

    … a critical need to accurately model human organ systems such as the liver in vitro. Currently, there are numerous limitations of in vitro cell culture models. We developed a microphysiological system (MPS) based on a new commercial microfluidic platform (Nortis Inc., Woodinville, WA) that can …

    washington Repository record for Development of a Liver-Kidney Dual Organ Microphysiological System for Predicting Organ-Organ Interactions in the Toxicity of Xenobiotics: Aristolochic Acid Nephrotoxicity as a proof of Principle (opens in a new tab)

  13. Human Vascular Microphysiological Systems for Drug Screening

    … cell culture assays or in vivo animal models. Microphysiological systems are small-scale three-dimensional (3D) tissue models that recapitulate the native tissue structure and function. An ideal microphysiological system is comprised of human cells embedded within a 3D matrix introduced to …

    duke Repository record for Human Vascular Microphysiological Systems for Drug Screening (opens in a new tab)

  14. Development of Microphysiological Models for the Assessment of Xenobiotic and Endobiotic Absorption and Disposition

    Animal models and in vitro systems have long been relied upon to provide insights into the toxicology, pharmacodynamics and pharmacokinetics of investigational drug candidates before they are administered to human subjects. In this respect, these systems serve as crucial gatekeepers, protecting …

    washington Repository record for Development of Microphysiological Models for the Assessment of Xenobiotic and Endobiotic Absorption and Disposition (opens in a new tab)

  15. Biomaterials research in the field of biocompatibility, cell adhesion, and applications in microfluidic systems /

    … modified for compatibility with microfluidic systems. A microphysiological system was developed, integrating a porous PC membrane, electrodes, and microenvironment sensors, designed for use with mammalian cells. This dissertation demonstrates that surface modification can be purposefully …

    vilnius Repository record for Biomaterials research in the field of biocompatibility, cell adhesion, and applications in microfluidic systems / (opens in a new tab)

  16. A Comparative Analysis of Nephrotoxicity Induced by Voclosporin and Cyclosporine A Using Kidney Microphysiological Systems

    … relevant, three-dimensional kidney microphysiological system (MPS) to compare the transcriptomic and cellular responses of PTECs exposed to CsA and VOC. Our analyses revealed that CsA induces broad perturbations in cell cycle progression and proteostatic pathways, coupled with robust …

    washington Repository record for A Comparative Analysis of Nephrotoxicity Induced by Voclosporin and Cyclosporine A Using Kidney Microphysiological Systems (opens in a new tab)

  17. Development of New Microelectromechanical Chip-Based Systems and Their Application for Cardiac Therapeutic Evaluation

    … arrays (MEAs) are currently used in microphysiological body-on-a-chip systems for the assessment of mechanical and electrical function of human cardiac muscle tissues. However, existing microcantilever devices used in these systems do not acquire direct electrical signals and often …

    ucf Repository record for Development of New Microelectromechanical Chip-Based Systems and Their Application for Cardiac Therapeutic Evaluation (opens in a new tab)

  18. Engineering Human Microphysiological Models to Investigate Bacterial Extracellular Vesicle–Driven Endothelial and Blood–Brain Barrier Dysfunction

    … toxic signals traveling through the circulatory system. This is especially dangerous in brain blood vessels since evidence suggests that BEVs may destabilize the protective blood–brain barrier (BBB), resulting in neuroinflammation associated with cognitive decline and development of neurological …

    rit Repository record for Engineering Human Microphysiological Models to Investigate Bacterial Extracellular Vesicle–Driven Endothelial and Blood–Brain Barrier Dysfunction (opens in a new tab)

  19. The rejuvenating effects of systemic factors from young human serum on human skin

    Systemic factors circulating through the bloodstream affecting multiple organs at the same time, hold great potential to be central regulators during the aging process of human tissues. As life expectancy continues to increase, there is a corresponding rise in the prevalence of age-associated …

    cau-kiel Repository record for The rejuvenating effects of systemic factors from young human serum on human skin (opens in a new tab)

Page 1 of 2