Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 86 for “"Micropump"”.

  1. SYNTHETIC JET MICROPUMP

    <p>The production of a novel micropump based on the synthetic jet principle is investigated both numerically and experimentally. The proposed micropump consists of a synthetic jet actuator driven by a vibrating diaphragm issuing into an inverted T- shaped channel structure forming the inlet/outlet …

    mcmaster Repository record for SYNTHETIC JET MICROPUMP (opens in a new tab)

  2. Development of micropump for microfluidic applications

    … covers the research work on two types of micropumps, one is based on magnetohydrodynamic (MHD) principle that utilizes Lorentz force for actuation, and the other is based on electrochemical actuation. The AC-type MHD micropump was designed and analyzed as a solution to the bubble formation …

    lsu-thes Repository record for Development of micropump for microfluidic applications (opens in a new tab)

  3. Magnetotheological Elastomeric Micropump Designs for Drug Delivery

    … valve Magnetorheological elastomeric (MRE) micropumps, which rely on an electromagnetic actuation mechanism, and evaluated the performance characteristics of five different MR micropump designs. Two of these designs were our proposed designs, while others were from the existing micropump …

    gsu Repository record for Magnetotheological Elastomeric Micropump Designs for Drug Delivery (opens in a new tab)

  4. OPTIMIZATION OF ALTERNATING CURRENT ELECTROTHERMAL MICROPUMP BY NUMERICAL SIMULATION

    … the optimization process of AC electro-thermal micropump with respect to the geometry of electrode array and channel height.</p> <p>The thesis first introduces the theories of AC electrokinetic including dielectrophoresis, AC electro-osmosis (ACEO) and AC electro-thermal (ACET). Also presented …

    ut-knoxville Repository record for OPTIMIZATION OF ALTERNATING CURRENT ELECTROTHERMAL MICROPUMP BY NUMERICAL SIMULATION (opens in a new tab)

  5. MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP

    … is that of designing and developing a micropump for on-chip applications that have requirements for simultaneous high differential pressures and high flow rates, particularly for gas flow applications. In the literature, there are designs that provide high differential pressures at low …

    oklahoma-thes Repository record for MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP (opens in a new tab)

  6. MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP

    … is that of designing and developing a micropump for on-chip applications that have requirements for simultaneous high differential pressures and high flow rates, particularly for gas flow applications. In the literature, there are designs that provide high differential pressures at low …

    oklahoma-thes Repository record for MULTIPHYSICS ANALYSIS OF HIGH DIFFERENTIAL PRESSURE ELECTROZIPPER PERISTALTIC MICROPUMP (opens in a new tab)

  7. Modeling, simulation, and fabrication of a PZT valveless micropump

    <p>A micropump is one of the most important elements in a micro-total analysis system used for rapid chemical and biological analysis. To date, different kinds of micropumps have been designed, fabricated, tested, and implemented. Among them, a PZT valveless micropump is receiving increasing …

    iastate Repository record for Modeling, simulation, and fabrication of a PZT valveless micropump (opens in a new tab)

  8. A flexible capacitance sensor integrated micropump for precise volume control

    Pneumatically actuated micropumps are operated by external pressure sources that enable deflection of the thin PDMS membrane. Depending on the geometrical parameters of the microvalve, these micropumps can deliver microliter to picoliter sample volumes precisely. However, the most conventional …

    ttu Repository record for A flexible capacitance sensor integrated micropump for precise volume control (opens in a new tab)

  9. Design and fabrication of a new 3D AC-electroosmotic micropump

    … of fluid handling devices such as micropumps. In biomedical technology, pumps for handling extremely small fluid amounts become more and more important where microsystems for biological analysis routinely use solid-state electrokinetic micropumps.<br/><br/>AC Electrokinetic …

    soton Download PDF for Design and fabrication of a new 3D AC-electroosmotic micropump (opens in a new tab)

  10. The Design and Development of an Electromagnetically Actuated Nozzle/Diffuser Micropump

    … of a magnetically actuated nozzle/diffuser micropump for use in the treatment of glaucoma. The micropump is composed of a cast poly(dimethylsiloxane) (PDMS) body containing all fluidic features, a spin coated PDMS membrane for sealing the fluidic features, and commercial silicone tubing for …

    queens Repository record for The Design and Development of an Electromagnetically Actuated Nozzle/Diffuser Micropump (opens in a new tab)

  11. DESIGN, FABRICATION, AND TESTING OF A PDMS MICROPUMP WITH MOVING MEMBRANES

    … traditional methods. A novel design of a PDMS micropump with multiple vibrating membranes has been developed for application in drug delivery and molecule sorting. The PDMS micropump consists of three nozzle/diffuser elements with vibrating membranes, which are used to create pressure …

    vcu Repository record for DESIGN, FABRICATION, AND TESTING OF A PDMS MICROPUMP WITH MOVING MEMBRANES (opens in a new tab)

  12. Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique

    … (GC) system. In a microfluidic system, the micropump is an essential component as an actuation sources to provide the driving force to mobilize fluids (liquid and gas) in a system. In this dissertation, development of an electrostatic valve-less peristaltic micropump for gas pumping is …

    uiuc Repository record for Development of an electrostatic peristaltic gas micropump and nanochannel fabrication technique (opens in a new tab)

  13. EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF PLANAR ION DRAG MICROPUMP GEOMETRICAL DESIGN PARAMETERS

    … applications in reliable and cost effective EHD micropumps for spot cooling. The study examines the development, fabrication, and operation of micropumps under static and dynamic conditions. An optimization study is performed using the experimental data from the micropump prototype tests, and a …

    maryland Repository record for EXPERIMENTAL AND COMPUTATIONAL INVESTIGATION OF PLANAR ION DRAG MICROPUMP GEOMETRICAL DESIGN PARAMETERS (opens in a new tab)

  14. PMP-NC² - a normally-closed, backpressure independentperistaltic micropump featuring a modular setup

    The presented thesis addresses a new concept for micropumps. The micropump PMP-NC² is based on a modular design with a re-usable actuator unit and a cost-efficient microfluidic chip, which is disposable and can easily be replaced after use or contamination. <br>The micropump is driven in a …

    freiburg-diss Repository record for PMP-NC² - a normally-closed, backpressure independentperistaltic micropump featuring a modular setup (opens in a new tab)

  15. A Controllable Flexible Micropump and a Semi-Active Vibration Absorber Using Magnetorheological Elastomers

    … elastomer (MRE) controllable flexible micropump. In addition, material characterizations of MRE, modeling, fabrication and testing of a MRE-based vibration absorber system are investigated.Theoretical modeling and analysis of a controllable flexible magnetically-actuated fluid transport …

    unr Repository record for A Controllable Flexible Micropump and a Semi-Active Vibration Absorber Using Magnetorheological Elastomers (opens in a new tab)

  16. Cochlear Micropump Drug Delivery System: A noninvasive technique for murine intracochlear drug delivery

    … implantable and scalable peristaltic micropump that provides programmable and accurate drug delivery for inner ear applications. Borkholder Labs used a non-invasive micro-CT imaging technique to create a 3-D atlas of the mouse cochlea to determine measurements for transport parameters …

    rit Repository record for Cochlear Micropump Drug Delivery System: A noninvasive technique for murine intracochlear drug delivery (opens in a new tab)

  17. Design and Characterization of an Electrohydrodynamic (EHD) Micropump for Cryogenic Spot Cooling Applications

    … the various components being cooled. Compact micropumps capable of pumping liquid nitrogen at 77 K into liquid-cooling circuits would enable a much more compact and lightweight method of maintaining a uniform temperature across the cooling circuit. These pumps can also address the demand for …

    maryland Repository record for Design and Characterization of an Electrohydrodynamic (EHD) Micropump for Cryogenic Spot Cooling Applications (opens in a new tab)

  18. Numerical and experimental investigations of the acoustic standing wave resonator, pump, and micropump

    … as well as the valveless acoustic pump and micropump are investigated. A new sixth-order accurate compact finite difference method for solving the Helmholtz equation with Neumann boundary conditions is developed. This scheme showed a better performance at higher wave numbers than the finite …

    concordia Download PDF for Numerical and experimental investigations of the acoustic standing wave resonator, pump, and micropump (opens in a new tab)

  19. Fabrication and characterization of a peristaltic micropump for use in medical drug delivery systems

    <p>A second-generation design micropump was fabricated and tested. The overall size of the micropump is 70 mm x 35 mm x 1 mm. The design of the micropump incorporates three chambers (12 mm in diameter, 180 [Mu]m deep) with 50 [Mu]m thick membranes, inlet and outlet valves, and flow channels (2 mm x …

    iastate Repository record for Fabrication and characterization of a peristaltic micropump for use in medical drug delivery systems (opens in a new tab)

  20. Viscoelastic Property Analysis of a Magnetorheological Elastomer Micropump for Insulin Delivery in Type 1 Diabetes

    … elastomer (MRE) bodily functioning micropump, a portable, lightweight, compact, and wireless insulin delivery system. This study builds a foundation for the additive manufacturing of a microfluidic pump with a magnetic actuation mechanism. The two main components of the micropump …

    gsu Repository record for Viscoelastic Property Analysis of a Magnetorheological Elastomer Micropump for Insulin Delivery in Type 1 Diabetes (opens in a new tab)

Page 1 of 5