Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 19 of 19 for “"Microscanner"”

  1. A point-of-care, microfluidic - based microscanner for the identification and counting of single cells

    Blood cell counting is related to the diagnosis and therapy of various diseases, from infections to blood disorders and cancer treatment. However, the time consuming procedures and the increased cost of standard medical equipment act as serious obstacles in the early screening of a disease. To meet …

    greece Repository record for A point-of-care, microfluidic - based microscanner for the identification and counting of single cells (opens in a new tab)

  2. Design, simulation and fabrication of a vertical microscanner for phase modulation interferometry - Application to optical coherence tomography system for skin imaging

    Cette thèse décrit le design, la simulation et la fabrication d’une matrice 4x4 de micro-miroirs actionnée verticalement et munie d’un capteur de position. Le micro-scanneur vertical a pour vocation à être intégré au sein d’un micro-interféromètre de Mirau de type matriciel, réalisé àbase de …

    star-france Repository record for Design, simulation and fabrication of a vertical microscanner for phase modulation interferometry - Application to optical coherence tomography system for skin imaging (opens in a new tab)

  3. MEMS micromirrors for imaging applications

    … connections and arrangement are fundamental. The microscanner introduced utilises two types of actuators, electrothermal actuators and electrostatic comb-drives, to scan a 1.2-mm-diameter gold coated silicon micromirror in two orthogonal axes. With assistance of FEM software, CoventorWare, the …

    strathclyde Repository record for MEMS micromirrors for imaging applications (opens in a new tab)

  4. Modèle d’irradiation mandibulaire chez le lapin et évaluation d’un traitement par ultrasons pulsés de faible intensité sur la régénération osseuse

    … osseuse, confirmée à l’histologie et au microscanner. Une fois mises en évidence les altérations osseuses radio-induites, nous avons pu renouveler le protocole en ajoutant une étape supplémentaire d’application de LIPUS sur les sites opératoires. Le protocole consistait en l’application …

    star-france Repository record for Modèle d’irradiation mandibulaire chez le lapin et évaluation d’un traitement par ultrasons pulsés de faible intensité sur la régénération osseuse (opens in a new tab)

  5. Modélisation de la reconstitution osseuse en chirurgie de l’enfant

    … et iliaque est utilisé. Une analyse par microscanner et des cultures de CFU-F sont effectuées. Résultats : Le micro-scanner permet une caractérisation précise de la structure du greffon en fonction de la force de compaction appliquée 0, 5, 20 et 50N. Le nombre de CFU-F (Colony …

    star-france Repository record for Modélisation de la reconstitution osseuse en chirurgie de l’enfant (opens in a new tab)

  6. Impact de l'ischémie reperfusion et de la conservation des organes sur l'intégrité vasculaire des organes : études dans un modèle de transplantation rénale porcine

    … corticale rénale après acquisition microscanner et traitement des images de reins de porc perfusés avec un polymère de silicone radio-opaque.RÉSULTATS : L’ischémie-reperfusion rénale induit une diminution corticale du volume du segment vasculaire associée à une raréfaction des …

    star-france Repository record for Impact de l'ischémie reperfusion et de la conservation des organes sur l'intégrité vasculaire des organes : études dans un modèle de transplantation rénale porcine (opens in a new tab) Restricted access

  7. Αλγόριθμοι ελέγχου κίνησης ηλεκτρομηχανικών συσκευών πολύ μικρής κλίμακας για την αποθήκευση πληροφορίας

    … κατευθύνσεις (x/y). Πληροφορία για τη θέση του microscanner στις δύο κατευθύνσεις παρέχεται από θερµικούς αισθητήρες ανίχνευσης θέσης που κατασκευάζονται µαζί µε τη διάταξη µε τους ανιχνευτές και τοποθετούνται πάνω από το κινητό πλαίσιο. Η πλήρης κατανόηση της συµπεριφοράς των διατάξεων αυτών …

    patras-thes Repository record for Αλγόριθμοι ελέγχου κίνησης ηλεκτρομηχανικών συσκευών πολύ μικρής κλίμακας για την αποθήκευση πληροφορίας (opens in a new tab)

  8. Caractérisation et études cinétiques de la formation de microémulsions bicontinues. Impact des asphaltènes

    … en œuvre de méthodes non-destructrices en RMN, Microscanner, SAXS et DLS ont permis de mieux comprendre les mécanismes de formation de microémulsions modèles et asphaltèniques selon deux modes : avec et sans agitation. Dans un second temps, l’impact des asphaltènes sur la structure des …

    star-france Repository record for Caractérisation et études cinétiques de la formation de microémulsions bicontinues. Impact des asphaltènes (opens in a new tab) Restricted access

  9. Validation des propriétés biologiques et structurelles d’allogreffes de tissus de l’appareil locomoteur issues d’un nouveau procédé de traitement

    … ainsi que les analyses histomorphométriques (microscanner) et de surface (MEB) ont permis de constater que l’os nettoyé était globalement plus rigide du fait de la délipidation mais conservait une micro/nano structure proche de celle de l’os congelé.Les cultures d’ostéoblastes ont montré que …

    star-france Repository record for Validation des propriétés biologiques et structurelles d’allogreffes de tissus de l’appareil locomoteur issues d’un nouveau procédé de traitement (opens in a new tab)

  10. Étude biologique et physico-chimique de verre bioactif / bisphosphonates et de vitrocéramique pour le comblement des pertes osseuses chez les petits animaux

    … évaluée après implantation chez des lapins. Le microscanner (mCT) montre la résorption du 46S6-10Zn-2Ti et l'osséo-intégration des cellules osseuses dans les pores du bio-implant alors que, l'étude histologique montre que le 46S6-10Zn-2Ti est presque totalement dégradé et remplacé par le tissue …

    star-france Repository record for Étude biologique et physico-chimique de verre bioactif / bisphosphonates et de vitrocéramique pour le comblement des pertes osseuses chez les petits animaux (opens in a new tab)

  11. Wireline sedimentology : resedimented volcaniclastites

    … The principal logs used are Formation MicroScanner (FMS) images, together with dipmeter-microresistivity, gamma ray and geochemical plots, taken during ODP Leg 129 in the Pigafetta and E. Mariana Basins, W. Central Pacific. </p><p> Seven resedimented volcaniclastic facies including …

    soton Repository record for Wireline sedimentology : resedimented volcaniclastites (opens in a new tab)

  12. M-anomaly Analyses and its implications for the architecture of the upper oceanic crust

    … resistivity imagery (electrofacies by Formation MicroScanner) combined with recovered cores and other logs. Highlights of this research are: (1) most of the extrusive section consists of massive flows and fragmented formations including breccias, which has important implications for the magnetic …

    tamu Repository record for M-anomaly Analyses and its implications for the architecture of the upper oceanic crust (opens in a new tab)

  13. Conception et réalisation d’un endomicroscope polarimétrique de Mueller à fibre en vue d’une application à l’aide au diagnostic médical in vivo

    … : 3 mm), incluant un système de balayage rapide (microscanner) par mise en résonance mécanique de l’extrémité de la fibre. Le filtre dichroïque miniaturisé nécessaire pour mettre en œuvre la méthode bichromatique est un réseau de Bragg photoinscrit dans le cœur de la fibre. La conception, la …

    star-france Repository record for Conception et réalisation d’un endomicroscope polarimétrique de Mueller à fibre en vue d’une application à l’aide au diagnostic médical in vivo (opens in a new tab)

  14. Fracture Analysis of the Lower Oceanic Crust, Atlantis Bank, Southwest Indian Ridge

    … logs (Ultrasonic Borehole Imager and Formation Microscanner) in order to locate and determine the orientation of fractures and joints throughout the three holes. The use of petrophysical tools is essential since they provide a near-continuous record of the borehole wall and record geographic …

    usm Repository record for Fracture Analysis of the Lower Oceanic Crust, Atlantis Bank, Southwest Indian Ridge (opens in a new tab)

  15. Les contraintes de charge asymétriques chez l'homme moderne : étude microCT sur l'os trabéculaire

    … sans activité particulière. Par une étude en microscanner avec des coupes de 41 microns, des volumes d'intérêt dans les os du squelette carpien radial ont été réalisés sur des individus d'âge jeune sans antécédent particulier de façon bilatérale. Plusieurs variables cliniques et …

    star-france Repository record for Les contraintes de charge asymétriques chez l'homme moderne : étude microCT sur l'os trabéculaire (opens in a new tab)

  16. Effet anti-calcifiant et anti-inflammatoire du Thiosulfate de sodium dans les calcifications ectopiques

    … sont prélevés, fixés au PFA4% puis analysés par microscanner. Les volumes et les densités calciques sont calculés. Résultats : Chez l'homme, un tiers des patients a répondu au TSS topique avec une réduction du volume de la calcification, dont trois disparitions complètes. L'application locale du …

    star-france Repository record for Effet anti-calcifiant et anti-inflammatoire du Thiosulfate de sodium dans les calcifications ectopiques (opens in a new tab) Restricted access

  17. Utilisation de cellules souches pulpaires combinées à une matrice de collagène pour la réparation osseuse cranio-faciale

    … des matrices et de la néo-angiogenèse) et au microscanner à rayons X (suivi cinétique de la qualité et de la quantité de matrice osseuse régénérée), .5 La validation et la confirmation de l'ensemble de ces résultats par l'histologie. Ainsi, ces résultats nous ont permis de répondre à …

    star-france Repository record for Utilisation de cellules souches pulpaires combinées à une matrice de collagène pour la réparation osseuse cranio-faciale (opens in a new tab) Restricted access

  18. A tip-tilt-piston micromirror with elastomeric universal joint fabricated via micro-masonry

    This thesis presents the design, analytical and numerical modeling, fabrication and characterization of a hybrid tip-tilt-piston micromirror driven by electrostatic actuation. The micromirror involves a single crystal silicon mirror and a conductive elastomeric universal joint which are …

    uiuc Repository record for A tip-tilt-piston micromirror with elastomeric universal joint fabricated via micro-masonry (opens in a new tab)

  19. Novel Actuation Mechanisms for MEMS Mirrors

    Recent developments in the rapidly emerging discipline of micro-electro-mechanical systems (MEMS) have shown special promise in sensors, actuators, and micro-optical systems. In fact, optics is an ideal application domain for MEMS technology as photons have no mass and are easier to be actuated …

    nus Repository record for Novel Actuation Mechanisms for MEMS Mirrors (opens in a new tab)