Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 28 for “"Microscribe"”.
-
Interaktivní manipulace s 3D objekty ve virtuálním prostoru s využitím 3D skeneru MicroScribe - 3D mys
… se zabývá zpracováním manipulátoru ke skeneru MicroScribe, který se v současné době nachází na Ústavu počítačové grafiky Fakulty informačních technologií VUT v Brně. Obsahem této práce je nejprve obeznámit čtenáře s teorií matic, trojrozměrných transformací a potom vysvětlit způsob komunikace …
-
Quantification of the variable radiocarpal ligaments pattern
… each radiocarpal ligament was measured with the microscribe digitiser and confirmed histologically. Results: The ligamentous attachments of the distal radius are highly variable. Unlike the manual and digital measurements, microscribe measurements provide more reproducible data as there was no …
-
Manuelle und computergestützte Modellanalyse bei Neugeborenen mit einseitiger Lippen-Kiefer-Gaumenspalte vor und nach funktioneller Lippenschluss-Operation nach Delaire
… dem dreiachsigen taktilen Digitalisierungsarm MicroScribe® digitalisiert und vermessen. Außerdem erfolgte die Modellanalyse mittels des orthodontisch-diagnostischen Bestecks nach Korkhaus und mit Hilfe einer digitalen Schieblehre. Dafür wurden an den prä- und postoperativen Modellen …
-
The investigation of craniofacial variation between archaic and intermediate-late periods of Chile using morphometric analysis
… All craniometric landmarks were recorded using a Microscribe™ 3D digitizer, with exclusion of mandibular landmarks. MorphoJ was utilized to analyze the geometric morphometric data. Coordinates using the Microscribe were recorded in order to investigate the differences in shape of the craniofacial …
-
The implications and effects of coronary venous anatomy on clinical interventions
… specimens with direct measurements using a microscribe digitizer and with contrast-computed tomography. Contrast-computed tomography and magnetic resonance imaging were used to investigate the coronary venous anatomical relationship with the phrenic nerve, coronary arteries, and mitral …
-
Estimating ancestry in South Africa: a comparison of geometric morphometrics and traditional craniometrics
… Cranial landmarks were digitized using a Microscribe G2 for geometric morphometric analysis in 3D-ID, and traditional craniometric measurements for use in FORDISC were calculated using the data collection software 3Skull. Data was collected from a total of 385 individuals (186 black and …
-
Cranial Base Height as an Indicator of Developmental Stress in Native Mexican and American-Born Mexican Populations
… Collection. Landmark data were collected using a Microscribe® G2 3D digitizer and 3Skull software. Data were analyzed with an ANOVA in Excel, using the Real Statistics Add-in. Males and females were analyzed separately in order to control for size differences associated with sex. Cranial base …
-
Musculoskeletal stress markers: a comparison between a 3D digitizing geometric morphometric approach and a more traditional scoring method using clavicles from a 19th century asylum collection from Pueblo, Colorado
… to results obtained from using a 3D digitizing MicroScribe, used to map the surface of the costoclavicular ligament, along with the attachment sites of the pectoralis major muscle and deltoideus muscle on the clavicle. The data from the 3D digitizer was analyzed using several different software …
-
Skull morphometry of the common dolphin, Delphinus sp., from New Zealand waters : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Conservation Biology at Massey University, Auckland, New Zealand
… data acquisition methods (callipers versus microscribe) was compared through the computation of three precision estimates (variance, mean absolute difference (MAD), and relative error magnitude (REM)). A total of 67 common dolphin skulls from stranded and by-caught individuals were available …
-
An analysis of sexual dimorphism using geometric morphometrics of the femur and tibia: the use of GM in assessing sex of fragmented remains
… and distal epiphyses of each bone using a Microscribe, which helps capture the overall size and shape variation present in the sample. Only individuals from one population, White, where analyzed in order to eliminate population variation bias. Classification rates for males and females for …
-
Metric, nonmetric, and geometric morphometric methods of sex estimation using the distal humerus
… (n=444)), and geometric morphometrics via a Microscribe digitizer and MorphoJ software (n=227). The sample was taken from the William M. Bass Donated Skeletal Collection and was primarily composed of White Americans. The male to female ratio was approximately equal. The results of the metric …
-
Geographic Origin Estimation of Latin American Individuals Using Craniometric Data
… were collected from each cranium using a Microscribe digitizer and the program ThreeSkull (Ousley, 2004). A discriminant function analysis, stepwise function, and canonical variates analysis were performed to look at the variation and classify the individuals. 75.25% of the time …
-
First Premolar Extraction Decisions and Effects
… recorded in all three planes of space with a MicroScribe G2X 3D digitizing system and distances were computer-generated using trigonometric algorithms. RESULTS: Removing a first premolar gave an average of 7.3 mm of space in each quadrant of which 3.8 mm (51%) was consumed by canine …
-
THREE-DIMENSIONAL GEOMETRIC MORPHOMETRIC SEX DETERMINATION AND MODELED FRAGMENTARY ANALYSIS OF THE HUMAN PUBIC BONE
… were digitized on each individual bone using a Microscribe Digitizer. Results from the Principal Components Analysis provide promising clustering between male and female groups, as well as indications that the method may be ancestry-specific, and that parity may have an effect on the shape of …
-
THREE-DIMENSIONAL GEOMETRIC MORPHOMETRIC SEX DETERMINATION AND MODELED FRAGMENTARY ANALYSIS OF THE HUMAN PUBIC BONE
… were digitized on each individual bone using a Microscribe Digitizer. Results from the Principal Components Analysis provide promising clustering between male and female groups, as well as indications that the method may be ancestry-specific, and that parity may have an effect on the shape of …
-
Functional Integration of the Hominin Forelimb
… and suspensory locomotion. Data collected with a microscribe 3-D digitizer on the scapula, humerus, radius, and ulna of Australopithecus sediba, Australopithecus afarensis, and Homo erectus were compared to a sample of Homo sapiens, Pan troglodytes, Pan paniscus, Gorilla gorilla, Pongo pygmaeus, …
-
Quantitative morphology of the lumbar facets, muscles and fascia in relation to core stability
… inferior lumbar articular facets were created by Microscribe. This allowed calculation of the facet orientation and surface area by Rhinoceros software. The surface area was increased towards the inferior vertebral levels, while the orientation became less sagittal inferiorly. The investigations …
-
Biomechanical reconstruction of the appendicular skeleton in three North American Jurassic sauropods
… Camarasaurus. A technique was developed using a Microscribe three-dimensional digitizer to capture external morphological data for skeletal reconstruction and determination of taxonomically useful features. The appendicular musculature of Alligator mississippiensis was dissected to determine …
-
Environmental stresses and its effect on craniofacial growth and development
… landmarks from 427 crania were registered with a MicroScribe 3DX digitizer. The data collected was utilized to investigate whether growth retardation was present in the sample, along with an analysis correlating pathological features to growth and development. A multiple regression analysis was …
-
Development of a freehand three-dimensional radial endoscopic ultrasonography system
… A 3D-EUS system was developed using a Microscribe positional arm and frame grabber card, to acquire the 3D dataset. A Matlab 3D-EUS toolbox was written to reconstruct and analyse the volumes. The 3D-EUS systems were evaluated on the EUS phantom and in clinical cases. The usefulness of …
Page 1 of 2