Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 13 of 13 for “"Microsecond pulses"”
-
Time Domain Dielectric Spectroscopy Analysis of HL-60 Cell Suspensions After Microsecond and Submicrosecond Pulsed Electric Fields
… voltage threshold cause electroporation for microsecond pulses and intracellular effects for submicrosecond pulses. Models describing these effects often depend on the electrical properties of the cell, which are altered by the PEF. Time domain dielectric spectroscopy was used to provide data …
-
Elektroporacijos taikymas transfekcijoms in vitro ir vėžinių ląstelių žudymui in vivo /
In our study, we used nanosecond and sub-microsecond electroporation as a promising method that could be applied for the transfection of mammalian cells and the development of anticancer therapy. The two-part study was performed in vitro and in vivo. In vitro, based on literature and experiments, a …
-
Demonstration of quantum enhanced LIDAR robust against classical jamming
… (OFCG) designed to produce high-efficiency, microsecond pulses optimised for photon generation through the Four Wave Mixing process. A new numerical model is introduced and utilised for the optimal design and refinement of the OFCG. The theoretical predictions of the model are validated by …
-
Spectroscopic investigation of plasmas in liquids
… discharges in liquids, initiated by 7 kV DC microsecond pulses, were studied using deionized water, saline, and potassium bromide solutions at varying concentrations. The discharge process includes a high-potential resistive phase and a subsequent arc phase characterized by bright emissions. …
-
The Effect of Multiple Pulses on Bacteria
… cell death. We have explored the effect of microsecond pulses of 13 kV/cm and 15 kV/cm electric field amplitude on the viability of Escherlchia coli. The pulse duration was varied from 4 μs to 32 μs, and the pulse number of 4 μs pulses from one to eight, Finally, the effect of separation …
-
The echo ranger : a fault locator for power cables
… losses in power cables attenuate and distort the pulses. This distortion limits the accuracy and range of equipment which must measure time intervals to the nearest 3 x 10⁻⁸ seconds. Basically, the Echo Ranger consists of a portable low-voltage impulse generator combined with a timing Oscillator …
-
Real-Time Measurements on the Effects of Ultra-Short High Voltage Pulses on HL-60 Cells
The application of high voltage microsecond pulses that are above a critical value, to biological cells, has been shown to cause electroporation (Neumann, 1989). In addition, ultra-short pulses of several tens to hundreds of nanoseconds duration have been recently shown to affect intracellular …
-
Diverse Effects of Nanosecond Pulsed Electric Fields on Mammalian Cells
… the electric fields, administered in short pulses to a cell, charge the plasma and internal membranes, which act as dielectric layers, and between these the cytoplasm acts as a conductive medium. The pulse lengths of this treatment are traditionally in the range of 0.1 to 20 ms. Since the …
-
High performance ion formation, separation, and focusing at ambient pressure for mass spectrometry
… Here, we demonstrated that high voltage pulses as short as ~100 ns with a ~900 µs delay between pulses can greatly decrease background chemical noise and increase performance in terms of signal-to-noise, sensitivity, and detection limits for small molecule analysis compared to the use of …
-
Towards near-atomic resolution imaging of microsecond nanoscale dynamics
… microscope to generate bright and intense microsecond electron pulses, which are then used to image fast and irreversible nanoscale dynamics with atomic resolution (Chapters 2 and 3). The second is a novel approach to time-resolved cryo-electron microscopy which boosts the temporal …
-
Processing and Switching Mechanisms of Materials for Memory Devices in Flexible Electronics
… into the desired ferroelectric β-phase using microsecond pulses of UV irradiation. Under optimal pulse durations, typical characteristics of dipolar and reversible hysteresis loops appear in ferroelectric PVDF, reaching a remnant polarization of 5.4 µC/cm2 and a coercive field around 120 MV/m. …
-
Συγκριτική ανάλυση και βελτιστοποίηση αντιδραστήρων ψυχρού πλάσματος για την αποδόμηση υπερ- και πολυφθοροαλκυλικών ενώσεων (PFAS) και άλλων ανθεκτικών οργανικών ρύπων σε υδατικά συστήματα
… discharge generation modes using high-voltage pulses of nanosecond and microsecond duration were also studied. In addition, the influence of parameters such as plasma gas composition, water matrix, and initial pollutant concentration was examined. The study is not limited to the evaluation of …
-
Etude de la perméabilisation de la membrane plasmique et des membranes des organites cellulaires par des agents chimiques et physiques
… de la dizaine de millisecondes à la centaine de microsecondes et d’amplitude de champ de l’ordre de 100 kV/m, perméabilisent la membrane plasmique uniquement. Cependant, récemment, des impulsions plus courtes, dites impulsions nanoseconde (quelques nanosecondes) et de plus grande amplitude de …