Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"Microvalve"”.

  1. An electromagnetically actuated rotary gate microvalve with bistability

    Two types of rotary gate microvalves are developed for flow modulation in a microfluidic system that operates at high flow rate and/or uses particulate flow. This research work encompasses design, microfabrication, and experimental evaluation of these microvalves in three distinct areas compliant …

    gatech Repository record for An electromagnetically actuated rotary gate microvalve with bistability (opens in a new tab)

  2. Development of a hydraulically actuated microvalve for space exploration

    … microfluidic analysis systems utilize pneumatic microvalves and pumps to manipulate target samples for molecular detection and provide high sensitivity and selectivity for detecting various organic compounds. Pneumatically actuated microvalves have been employed extensively in terrestrial …

    ttu Repository record for Development of a hydraulically actuated microvalve for space exploration (opens in a new tab)

  3. An Electromagnetic Actuated Microvalve Fabricated on a Single Wafer

    Microvalves are essential components of the miniaturization of the fluidic systems to control of fluid flow in a variety of applications as diverse as chemical analysis systems, micro-fuel cells, and integrated fluidic channel arrangements for electronic cooling. Using microvalves, these systems …

    gatech Repository record for An Electromagnetic Actuated Microvalve Fabricated on a Single Wafer (opens in a new tab)

  4. Design, Analysis, Fabrication and Testing of a Novel Thermally-Actuated Hybrid Microvalve

    … of “smart irrigation” systems that leverage microvalves for precise delivery of water volumes (“on demand”) to individual plant based on the irrigation needs of each plant or tree. Thus, the long-term goal is to develop and improve irrigation systems in agricultural operations (which also …

    tamu Repository record for Design, Analysis, Fabrication and Testing of a Novel Thermally-Actuated Hybrid Microvalve (opens in a new tab)

  5. Mechanical and electrical properties of carbon nanotubes surface-stamped on polydimethylsiloxane for microvalve actuation

    I report on the study of the electrical and mechanical effects of the inclusion of a thin layer of multiwalled carbon nanotubes (MWCNT) into the surface of polydimethylsiloxane (PDMS) as a method of creating an electrically actuated, flexible microfluidic valve. Samples of PDMS loaded with various …

    unm Repository record for Mechanical and electrical properties of carbon nanotubes surface-stamped on polydimethylsiloxane for microvalve actuation (opens in a new tab)

  6. Design, fabrication and testing of an electrically controlled microfluidic capillary microvalve based on hydrophobicity

    Microfluidics is a promising disciple that combines "micro" amount of fluid handling in "micro" sized channels and has found applications in diverse fields such as biotechnology and environmental monitoring. Combination of microfluidics with digital electronics technology has spurred creation of …

    colostate Repository record for Design, fabrication and testing of an electrically controlled microfluidic capillary microvalve based on hydrophobicity (opens in a new tab)

  7. Design, characterisation and optimisation of a SAW correlator driven, wireless, passive microvalve for biomedical applications.

    … design a novel RF powered, secure coded, active microvalve with fully passive components. By combining the complex signal processing capabilities of the acoustic wave correlator with the electrostatic actuation of the microchannel, the advantages of both the mechanisms are incorporated into a …

    adelaide Repository record for Design, characterisation and optimisation of a SAW correlator driven, wireless, passive microvalve for biomedical applications. (opens in a new tab)

  8. A reconfigurable tactile display based on polymer MEMS technology

    … a microactuator array and a complementary microvalve (control) array. The concept, fabrication, and characterization of a kinematically-stabilized polymeric microbubble actuator (¡°endoskeletal microbubble actuator¡±) were presented. A systematic design and modeling procedure was carried …

    gatech Repository record for A reconfigurable tactile display based on polymer MEMS technology (opens in a new tab)

  9. Modeling and Simulation of Components and Circuits with Intrinsically Active Polymers

    … developed. A hydrogel-based stimulus-sensitive microvalve is the core element of the microfluidic toolbox. Essential material properties as swelling-stimuli functions and the cooperative diffusion are extracted from measurements. The results provide necessary input data for finite element …

    qucosa-diss

  10. Design and development of novel polymer based microsensors and microactuators

    … the design, simulation and fabrication of a microvalve based on pH-sensitive hydrogel which is naturally closed when consuming no power. The swelling/deswelling of the hydrogel in basic/acidic buffer medium is used as the actuation mechanism for the microvalve. The hydrogel expansion and …

    hawaii Repository record for Design and development of novel polymer based microsensors and microactuators (opens in a new tab)

  11. Electrokinetic phenomena of electrically induced Janus droplets and their applications

    … Janus droplets are introduced in this thesis: microvalve and micromotor. The EIJD-based microvalve is controllable using electric field. By testing the performance of the microvalve systematically, the capability of such an EIJD-based microvalve in sealing, switching time and flow rate control …

    waterloo Repository record for Electrokinetic phenomena of electrically induced Janus droplets and their applications (opens in a new tab)

  12. The development of microfluidic platforms for environmental analysis

    … of current centrifugally-automatable pneumatic microvalve mechanisms for increased actuation predictability, and the further combination of both of these detection and microvalve mechanisms for a complete on- disc, multi-toxin detection platform which has been designed specifically to be …

    dcu Download PDF for The development of microfluidic platforms for environmental analysis (opens in a new tab)

  13. Computational Study of Transport Phenomena and Deformation Behavior of Stimuli Sensitive Hydrogels

    … of hydrogel in microfluidics field as autonomous microvalve. A mathematical framework model for deformation of hydrogel, which takes into account conservation of mass, momentum, species and energy has been derived and analyzed and validated against experimental equilibrium swelling and deformation …

    nus Repository record for Computational Study of Transport Phenomena and Deformation Behavior of Stimuli Sensitive Hydrogels (opens in a new tab) Download file for Computational Study of Transport Phenomena and Deformation Behavior of Stimuli Sensitive Hydrogels (opens in a new tab)

  14. Electrostatically Actuated Microvalves Fabricated with Soft-Lithographic Techniques for Integrated Microfluidics

    … systems, however, requires the development of a microvalve that can effectively control connectivity between microfluidic components. Ideally, the valve should be fabricated with simple techniques at low temperature and ambient pressure to facilitate wide dissemination of the technology and also …

    uiuc Repository record for Electrostatically Actuated Microvalves Fabricated with Soft-Lithographic Techniques for Integrated Microfluidics (opens in a new tab)

  15. Design of a Microfluidic Based Lab-on-a-chip for Integrated Sample Manipulation and Dispensing

    … on Dielectric (EWOD) sample manipulator and a microvalve that controls the flow at the interface. An electrostatically actuated non-contact type drop-on-demand based microdispenser was developed. The dispenser was designed using finite element modeling technique that solved electrostatically …

    toronto-retro Repository record for Design of a Microfluidic Based Lab-on-a-chip for Integrated Sample Manipulation and Dispensing (opens in a new tab)

  16. Reduction of Unsteady Stator-Rotor Interaction by Trailing Edge Blowing Using MEMS Based Microvalves

    … Each blowing hole is connected to a MEMS based microvalve, which controls the blowing rate of the hole. The microvalve is actuated by a signal voltage, generated by a PID controller that accepts free stream and wake axial flow velocities as inputs and minimizes their difference. To quantify the …

    vt Repository record for Reduction of Unsteady Stator-Rotor Interaction by Trailing Edge Blowing Using MEMS Based Microvalves (opens in a new tab)

  17. A Customer Programmable Microfluidic System

    … devices and each device containing a multilayer microvalve. The microvalve uses a thermal pneumatic actuation method to switch and/or control the fluid flow in the integrated microchannels. It provides a means to isolate samples of interest and channel them from one location of the system to …

    ucf Repository record for A Customer Programmable Microfluidic System (opens in a new tab)

  18. Fabrication and characterization of a polydimethylsiloxane microfluidic pump for direct-sampling neuroscience experiments, with in-line capillary electrophoresis - laser-induced fluorescence chemical analysis

    … cantilevers, with a precision machined microvalve attached to the tip of each cantilever actuator. Registration of the cantilevers and microvalves over the PDMS microchannel, was accomplished with the aid of in-house machined micropositioners. The micropump was thoroughly characterized, …

    umn Repository record for Fabrication and characterization of a polydimethylsiloxane microfluidic pump for direct-sampling neuroscience experiments, with in-line capillary electrophoresis - laser-induced fluorescence chemical analysis (opens in a new tab)

  19. Bucky gel actuator for morphing applications

    … that BGA has the capability to be employed as a microvalve. A flow regulator utilizing a BGA microvalve was designed and fabricated. Flow rate measurements showed the capability of BGA-valve in manipulating the flow rate in different ranges.

    lsu-thes Repository record for Bucky gel actuator for morphing applications (opens in a new tab)

Page 1 of 3