Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 12 of 12 for “"Microwave interferometry"”.

  1. Microwave Interferometry Diagnostic Applications for Measurements of Explosives

    Microwave interferometry (MI) is a Doppler based diagnostic tool used to measure the detonation velocity of explosives, which has applications to explosive safety. The geometry used in existing MI experiments is cylindrical explosives pellets layered in a cylindrical case. It is of interest to …

    calpoly Repository record for Microwave Interferometry Diagnostic Applications for Measurements of Explosives (opens in a new tab)

  2. Ambient vibration measurements for non-destructive evaluation of structures by means of seismic methods and ground-based microwave interferometry

    … the main features of the Ground-based Radar Interferometry to perform remote measurements of vibrations, using the phase difference between reflected signals coming from the surface of the same object inside the radar scenario. This technique has been developed in relatively recent years and …

    cagliari Repository record for Ambient vibration measurements for non-destructive evaluation of structures by means of seismic methods and ground-based microwave interferometry (opens in a new tab)

  3. Methods and analyses for evaluation of erosive burning in solid propellants

    … erosive burning accurately. The theory for the microwave burning rate measurement technique was also presented. Although this technique has never been applied to the measurement of erosive burning, it has high resolution and does not interfere with the internal flow over the propellant. For …

    vt Repository record for Methods and analyses for evaluation of erosive burning in solid propellants (opens in a new tab)

  4. Kinetics and radiative processes of a xenon and iodine inductive RF discharge at low pressure

    … absorption spectroscopy, emission spectroscopy, microwave interferometry, and microwave absorption. Results from this research indicate that Xe + I$\sb2\sp{*}\sp{*}{\to}$ XeI* + I is the major precursor reaction leading to XeI* radiation. This conclusion differs from those resulting from research …

    uiuc Repository record for Kinetics and radiative processes of a xenon and iodine inductive RF discharge at low pressure (opens in a new tab)

  5. Plasma Diagnostics of Discharges in Nitrogen-Trifluoride (Etching, Semiconductor)

    … the photodetached electron density with microwave interferometry. The steady state negative ion density was found to be 50 times larger than the steady state electron density. Finally, the kinetics of product formation were examined by observing the optical emission from a pulsed …

    uiuc Repository record for Plasma Diagnostics of Discharges in Nitrogen-Trifluoride (Etching, Semiconductor) (opens in a new tab)

  6. Microwave diagnostics on a railgun plasma

    This thesis describes microwave interferometry measurements on the High Energy Railgun Apparatus (HERA) at Texas Tech University. Chapter I discusses railguns in general, basic railgun theory, and problems encountered whh railguns. The physical railgun system is described and illustrated as well as …

    ttu Repository record for Microwave diagnostics on a railgun plasma (opens in a new tab)

  7. Comprehensive study of high power ignitrons

    … diagnostic investigations, including optical and microwave interferometry, have been conducted. Special ignitrons, some of which had optical access to the discharge volume, have been used to achieve this. Application of the magnetic field caused a drastic reduction in the holdoff voltage …

    ttu Repository record for Comprehensive study of high power ignitrons (opens in a new tab)

  8. Time-Resolved Measurements of Plasma Electron Number Density and Electron-Neutral Collision Frequency Using a Microwave Diagnostic Method

    <p>Microwave interferometry is an established non-perturbing plasma diagnostic technique. Compared with other diagnostic techniques, it can be more robust and reliable in experimental applications. This thesis studies a simple and accurate microwave diagnostic method to characterize the electron …

    ut-knoxville Repository record for Time-Resolved Measurements of Plasma Electron Number Density and Electron-Neutral Collision Frequency Using a Microwave Diagnostic Method (opens in a new tab)

  9. Kinetics and radiactive processes of a XE and I2 inductive RF discharge at low pressure

    … absorption spectroscopy, emission spectroscopy, microwave interferometry, and microwave absorption. Results from this research indicate that Xe + I 2** ~ Xei* + I is the major precursor reaction leading to Xei* radiation. This conclusion differs from those resulting from research performed at …

    uiuc Repository record for Kinetics and radiactive processes of a XE and I2 inductive RF discharge at low pressure (opens in a new tab)

  10. Microwave Photonics for Distributed Sensing

    In the past few years, microwave-photonics technologies have been investigated for optical fiber sensing. By introducing microwave modulation into the optical system, the optical detection is synchronized with the microwave modulation frequency. As a result, the system has a high SNR and thus an …

    clemson Repository record for Microwave Photonics for Distributed Sensing (opens in a new tab)

  11. 3D Micromachining of Optical Devices on Transparent Material by Ultrafast Laser

    … application. An incoherent optical carrier based microwave interferometry technique was used for in-situ weak reflector fabrication and a picosecond laser micromachining technique was introduced for developing LOCs with unlimited utilization potential.

    clemson Repository record for 3D Micromachining of Optical Devices on Transparent Material by Ultrafast Laser (opens in a new tab)

  12. Analysis and simulation of small scale microwave interferometer experiments on non-ideal explosives

    … These small scale experiments utilize a 35 GHz microwave interferometer to measure the instantaneous shock and failing detonation wave velocities in explosives. Only those explosives which are transparent to the microwave radiation are evaluated, including ammonium nitrate plus fuel oil (ANFO). …

    purdue-thes Repository record for Analysis and simulation of small scale microwave interferometer experiments on non-ideal explosives (opens in a new tab)