Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 23 for “"Middle-down"”.

  1. Development and application of OmpT-based middle down proteomics

    … strategies -- the ""bottom-up"" and ""top-down"" approaches. Bottom-up proteomics relies upon enzymatic protein digestions (mostly by trypsin) prior to on-line liquid chromatography-coupled tandem mass spectrometry analysis (LC-MS/MS) of post-digestion peptides. Top-down proteomics omits …

    uiuc Repository record for Development and application of OmpT-based middle down proteomics (opens in a new tab)

  2. Ion Mobility-Mass Spectrometry to Augment Middle-Down Fragmentation Coverage

    … proteomics approaches, and they are bottom-up, middle-down and top-down methods. Bottom-up is a well-developed and high-throughput technique involving the digestion of proteins into peptides and separation of the peptides by liquid chromatography and analysis by mass spectrometry. While …

    unr Repository record for Ion Mobility-Mass Spectrometry to Augment Middle-Down Fragmentation Coverage (opens in a new tab)

  3. From Technology to Chromatin Biology: Contemporary Mass Spectrometry of Histones and Chromatin Associated Proteins

    We have also developed a top down-like approach (middle down) which analyzes large peptides to characterize PTM profiles on histone H3. Interestingly, we were able to conclude that methylation and acetylation levels on histone H3 are highly effected by perturbations of DNA methylation. In the past …

    uiuc Repository record for From Technology to Chromatin Biology: Contemporary Mass Spectrometry of Histones and Chromatin Associated Proteins (opens in a new tab)

  4. Mass spectrometry analysis of proteins and protein phosphorylation using functionalized polymer materials

    … digestion of proteins to larger peptides (middle-down proteolysis) can improve protein sequence coverage in MS analysis and reveal a wider range of phosphorylation sites than complete digestion. Initially, this dissertation reviews recent studies on phosphopeptide enrichment and middle-down …

    msu Repository record for Mass spectrometry analysis of proteins and protein phosphorylation using functionalized polymer materials (opens in a new tab)

  5. Analyzing Post Translational Modifications on Yeast Core Histones Using Fourier Transform Mass Spectrometry

    "In the end, a ""Middle-Down"" mass spectrometry approach has also been developed to study the kinetics of autoacetylation for the histone acetyltransferase, p300."

    uiuc Repository record for Analyzing Post Translational Modifications on Yeast Core Histones Using Fourier Transform Mass Spectrometry (opens in a new tab)

  6. Alterations in the Primary Structures of Ribosomal Proteins in Acquired Drug Resistance

    … proteins were identified using bottom-up and middle-down mass spectrometric approaches. An additional 7 N-terminal fragments were identified by top-down high resolution mass spectrometric analysis. Forty of the 52 N-terminal peptides were observed to have lost their N-terminal methionine and …

    maryland Repository record for Alterations in the Primary Structures of Ribosomal Proteins in Acquired Drug Resistance (opens in a new tab)

  7. Mass Spectrometry Methods For Enhanced Analysis Of Epigenetic And Epitranscriptomic Modifications

    … to biological systems. Specifically, I address middle-down proteomics of histone tails, which is sparsely performed due to technical challenges. I introduce a simplified method that is robust and reliable and can quantitate both middle-down and bottom-up histone peptides simultaneously. Histone …

    penn Repository record for Mass Spectrometry Methods For Enhanced Analysis Of Epigenetic And Epitranscriptomic Modifications (opens in a new tab)

  8. Untersuchung des Einflusses von APOE Isoformen auf die Proteome von Geweben und Zellen

    … Abschließend wurden durch Bottom-Up und Middle-Down-Methoden potentielle APOE Interaktionspartner in co-immunpräzipitierten APOE3 und APOE4 transfizierten Huh7-Zellen identifiziert.

    cau-kiel Repository record for Untersuchung des Einflusses von APOE Isoformen auf die Proteome von Geweben und Zellen (opens in a new tab)

  9. Development and Application of Next Generation Mass Spectrometry for Protein Analysis at High-Resolution

    … modifications on a high throughput basis. Called Middle Down Proteomics, this process identified 7454 peptides from 2-20 kDa (1472 unique) from 555 proteins after just 23 LC-MS/MS injections. Along with greatly increased confidence for peptide identification (expectation values from 10-89 to 104) …

    uiuc Repository record for Development and Application of Next Generation Mass Spectrometry for Protein Analysis at High-Resolution (opens in a new tab)

  10. Protease-containing membranes for rapid, controlled antibody digestion prior to mass spectrometry analysis

    … membranes yields "bottom-up" (1-2 kDa) to 'middle-down' (5-15 kDa) peptides in less than 10 min. These peptic peptides cover the entire sequences of Herceptin and a WatersTM antibody. Compared with the performance of bottom-up (in-solution tryptic digestion) and top-down (intact protein …

    msu

  11. Development of ultraviolet photodissociation for high-throughput analysis of heavily modified proteins and peptides

    … workflow, analysis of heavily modified larger middle down sized peptides, and heavily modified intact proteins in a top-down proteomics workflow. UVPD uses higher energy ultraviolet photons (193 nm, 6.4 eV per photon), which are absorbed by the backbone to activate and dissociate ions …

    texas Repository record for Development of ultraviolet photodissociation for high-throughput analysis of heavily modified proteins and peptides (opens in a new tab)

  12. Development of ultrafast protein digestion and standards free quantitation methods for mass spectrometric analysis

    … characterization of proteins via bottom up and middle down approaches often requires time consuming reduction and enzymatic digestion steps to ensure protein cleavage into subunits or peptides. Chemical artifacts can also be induced due to chemical modifications that can occur in-solution during …

    njit Repository record for Development of ultrafast protein digestion and standards free quantitation methods for mass spectrometric analysis (opens in a new tab)

  13. Characterization of peptides and proteins by ultraviolet photodissociation mass spectrometry for biotechnology applications

    … suit each application, including bottom-up and middle-down proteolysis as well as top-down analysis. High resolution mass spectrometry instrumentation and modern tandem mass spectrometry platforms are integral to the research presented in this dissertation. In addition to UVPD, a variety of …

    texas Repository record for Characterization of peptides and proteins by ultraviolet photodissociation mass spectrometry for biotechnology applications (opens in a new tab)

  14. Development and application of quantitative liquid chromatography – mass spectrometry techniques to facilitate enhanced bioprocessing of therapeutic proteins

    … advanced LC-MS methods including high resolution middle down mass spectrometry; intact protein analysis of critical quality attributes, stable isotope based quantitative glycan analysis and hydrogen deuterium exchange mass spectrometry for structural comparability analysis. In addition data …

    dcu Download PDF for Development and application of quantitative liquid chromatography – mass spectrometry techniques to facilitate enhanced bioprocessing of therapeutic proteins (opens in a new tab)

  15. Development of Methodologies for the Proteoform-centric Analysis of Complex Proteomes

    … mass spectrometry (MS)-based bottom-up (BU), middle-down (MD), and top-down (TD) proteomics. In BU proteomics, proteoforms are enzymatically digested into peptides, which are identified and then assigned to protein groups by inference algorithms. MD proteomics is based on the same principle; …

    cau-kiel Repository record for Development of Methodologies for the Proteoform-centric Analysis of Complex Proteomes (opens in a new tab)

  16. Development of mass spectrometry and ion mobility methods and instrumentation for the characterization of proteins from primary sequence to higher order structure

    … photodissociation (UVPD), when applied in both middle-down and top-down proteomic workflows, produced higher sequence coverage when compared to collisional activation methods. Using carbamylation of lysine to restrict tryptic cleavage to less common arginine residues, larger peptides were …

    texas Repository record for Development of mass spectrometry and ion mobility methods and instrumentation for the characterization of proteins from primary sequence to higher order structure (opens in a new tab)

  17. Development of miniaturized bioanalytical methods for the qualitative and quantitative analysis of proteins and proteomes by means of digital microfluidics and nanoLC-MS

    … scale, which inevitably requires suitable downscaling of sample preparation workflows as well. The overall goals of this thesis were to investigate and develop promising sample preparation methods for handling low-input biological samples, and adapt these methods to become suitable for …

    cau-kiel Repository record for Development of miniaturized bioanalytical methods for the qualitative and quantitative analysis of proteins and proteomes by means of digital microfluidics and nanoLC-MS (opens in a new tab)

  18. Elucidation Of Histone Modifications And Nucleosomal Structure Using Novel Mass Spectrometry Approaches

    … dissociation (ETD) MS/MS methodology with middle-down and top-down MS, we are able to measure deuterium content of tail domains with near site-specific resolution for the first time. We find that all tails undergo decreased structural rigidity upon incorporation into the nucleosome, lending …

    penn Repository record for Elucidation Of Histone Modifications And Nucleosomal Structure Using Novel Mass Spectrometry Approaches (opens in a new tab)

  19. Glycan sequencing and isoaspartate characterization by electron activated dissociation tandem mass spectrometry

    … during trypsin digestion, a comprehensive top-down ExD method was developed to identify both asparagine deamidation and isoaspartate formation at the level of the intact protein With the consideration that the top-down strategy will eventually fail for high molecular weight proteins, a …

    bu Repository record for Glycan sequencing and isoaspartate characterization by electron activated dissociation tandem mass spectrometry (opens in a new tab)

  20. Applications of ion mobility spectrometry, collision-induced dissociation and electron activated dissociation tandem mass spectrometry to structural analysis of proteins, glycoproteins and glycans

    … of high-energy electrons, was optimized for both middle-down and bottom-up analyses of glycopeptides, including peptides with multiple glycosylation sites. Hot ECD was shown to be an effective fragmentation technique for sequencing of glycopeptides, even for ions in lower charge states. In …

    bu Repository record for Applications of ion mobility spectrometry, collision-induced dissociation and electron activated dissociation tandem mass spectrometry to structural analysis of proteins, glycoproteins and glycans (opens in a new tab)

Page 1 of 2