Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"Milk Substrate"”.

  1. The Development of an Improved Milk Substrate for Rennet Coagulation Assay on an Automatic Clot-Timer

    A substrate was developed for measuring the milk clotting strength of rennet preparations on an automatic clot-timer. The substrate contained 8 percent pasteurized skim milk solids, 1 percent chloroform, 0.3 percent 200 bloom gelatin, 0.03 M added CaCl2 and was buffered to pH 6.6 with 0.057 M …

    utahstate Repository record for The Development of an Improved Milk Substrate for Rennet Coagulation Assay on an Automatic Clot-Timer (opens in a new tab)

  2. BIOTECHNOLOGICAL APPLICATIONS TO DERIVE ADDED-VALUE INGREDIENTS FROM DAIRY PRODUCTS AND TO ASSESS EFFICIENCY OF ELECTROMICROBIAL PROTEIN PRODUCTION

    … culprit behind the decreased demand for skim milk and its products. The declining consumer demand has led to negative financial consequences for producers and also results in deleterious environmental effects caused by skim milk waste. Fermentation was evaluated as a method for removal of …

    cornell Repository record for BIOTECHNOLOGICAL APPLICATIONS TO DERIVE ADDED-VALUE INGREDIENTS FROM DAIRY PRODUCTS AND TO ASSESS EFFICIENCY OF ELECTROMICROBIAL PROTEIN PRODUCTION (opens in a new tab)

  3. Initial studies on the temperature-phased anaerobic biofilter process

    … TCOD reductions in excess of 90% for a synthetic milk substrate over a range of system COD loadings from 2 g/L/day to 16 g/L/day. There was little difference in performance between the three TPAB systems based on COD reductions and methane production; the 1:7 volume ratio thermophilic:mesophilic …

    iastate Repository record for Initial studies on the temperature-phased anaerobic biofilter process (opens in a new tab)

  4. Laboratory studies on the anaerobic sequencing batch reactor

    … of batch feeding, it is possible to achieve low substrate concentrations just prior to the settling phase. This condition results in low gas production during the settle/decant cycles and excellent solids separation within the reactor. Thus no external clarifier is required. Also, the process …

    iastate Repository record for Laboratory studies on the anaerobic sequencing batch reactor (opens in a new tab)

  5. Improved Control of Cheese Manufacture Through Continuous Vat Monitoring of Coagulation Parameters Using The Hot Wire Method

    … for cheese production automation. Coagulation of milk substrate was measured with the hot wire instrument and by four other methods: Formagraph, Brookfield®, vixcometer, Omnispec™ bioactivity monitor, and Sommer and Matsen rolling bottle method. The hot wire, using the time at maximum slope, …

    utahstate Repository record for Improved Control of Cheese Manufacture Through Continuous Vat Monitoring of Coagulation Parameters Using The Hot Wire Method (opens in a new tab)