Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 55 for “"Millifluidic"”

  1. DEVELOPMENT OF CONTINUOUS ENZYMATIC PROCESSES USING MILLIFLUIDIC DEVICES

    … we aim to address the challenges by developing millifluidic enzymatic processes which require small sample volume and an enzyme immobilization strategy which is applicable for decorating inert plastic surfaces of millifluidic devices.

    nus Repository record for DEVELOPMENT OF CONTINUOUS ENZYMATIC PROCESSES USING MILLIFLUIDIC DEVICES (opens in a new tab)

  2. Micro- and millifluidic platforms for imaging agent synthesis

    … past decades, but few efforts have focused on millifluidic mixers and millifluidic platforms in general. Millifluidic devices offer some of the same advantages as microfluidics, such as rapid heat and mass transfer, but also enable higher throughput and are typically easier to fabricate. In …

    uiuc Repository record for Micro- and millifluidic platforms for imaging agent synthesis (opens in a new tab)

  3. Continuous, Passive Liquid-Liquid Extraction and Emulsion Separation Within Microfluidic and Millifluidic Devices

    Liquid-liquid extraction (LLE) is a method used to separate compounds based on their relative activity in two immiscible phases. By significantly reducing the scale of liquid-liquid extraction to the micro- and milli-fluidic levels, this separation process can bemade suitable for low volume, high …

    bucknell Repository record for Continuous, Passive Liquid-Liquid Extraction and Emulsion Separation Within Microfluidic and Millifluidic Devices (opens in a new tab)

  4. Design and Fabrication of Optomechanical Formalin Fixation Monitoring Systems Integrated with a Millifluidic Device

    … quality monitoring system for an automated millifluidic system for pathology and the development cycle includes design, fabrication, testing, and evaluation of the systems. In our lab, a novel automated millifluidic system for cancer diagnosis using core needle biopsy (CNB) was under …

    washington Repository record for Design and Fabrication of Optomechanical Formalin Fixation Monitoring Systems Integrated with a Millifluidic Device (opens in a new tab)

  5. Highly structured polymer foams from liquid foam templates using millifluidic lab-on-a-chip techniques

    Les mousses polymères appartiennent à la famille des mousses solides qui sont des matériaux polyvalents, largement utilisés dans un grand nombre d'applications telles que l'automobile, l'emballage, produits de sport, isolants thermiques et acoustiques ou l'ingénierie tissulaire. Composé de bulles …

    star-france Repository record for Highly structured polymer foams from liquid foam templates using millifluidic lab-on-a-chip techniques (opens in a new tab)

  6. Conceptual Propellant Feed System for Electrospray Thrusters and an Exploration into 3D Printed Millifluidic Manifolds

    … a peristaltic pump, and an MSLA 3P printed (3DP) millifluidic propellant routing manifold (PRM). Primary goals were to develop a leak-free bladder tank to deliver 100 grams of IL and fabricate a 3DP millifluidic PRM to simultaneously distribute propellant to four thrusters. Seal strength tests …

    ut-knoxville Repository record for Conceptual Propellant Feed System for Electrospray Thrusters and an Exploration into 3D Printed Millifluidic Manifolds (opens in a new tab)

  7. Development of a non contact calorimeter in isoperibolic millifluidic systems using InfraRed Thermography : applied to biphasic flows

    Ce travail porte sur le développement d’une technique de calorimétrie sans contact pour des écoulements diphasiques. Ces derniers sont réalisés sur la forme d’un train gouttes dans des tubes de taille millimétriques dans des supports isopériboliques. L’idée principale est de coupler la …

    star-france Repository record for Development of a non contact calorimeter in isoperibolic millifluidic systems using InfraRed Thermography : applied to biphasic flows (opens in a new tab)

  8. Green and sustainable synthesis of silver nanowires using batch and millifluidic processes and their applications in conductive inks

    … procedure is then tried in a continuous millifluidic reactor to increase the yield of silver nanowires by ~32%. The millifluidic process can improve mass and heat transfer, thanks to its miniaturized environment, and a more consistent control over the size and morphology of …

    okstate Repository record for Green and sustainable synthesis of silver nanowires using batch and millifluidic processes and their applications in conductive inks (opens in a new tab)

  9. Time-Resolved Investigations of Continuous Flow Synthesis of Nanomaterials and Catalysis Using Millifluidic Reactors for Biomass Conversion Reactors

    Millifluidics can be used as a simple tool and convenient platform to perform in-situ investigations on nanoparticles synthesis to generate real-time information in a continuous flow fashion. These investigations can be used to observe the relationship between the structure and performance of …

    lsu-thes Repository record for Time-Resolved Investigations of Continuous Flow Synthesis of Nanomaterials and Catalysis Using Millifluidic Reactors for Biomass Conversion Reactors (opens in a new tab)

  10. Poly(L-lysine)-grafted-poly(ethylene glycol) nanoparticles for delivery of proteins: Effects of stimulus-responsive crosslinking and tunable millifluidic assembly

    … parameters associated with batch synthesis. A millifluidic process was developed to encapsulate (BSA) in PLL-g-PEG through electrostatic self-assembly. The millifluidic process produced tunable nanoparticles (13 - 300 nm) that fully encapsulated the protein, retained its activity, and protected …

    okstate Repository record for Poly(L-lysine)-grafted-poly(ethylene glycol) nanoparticles for delivery of proteins: Effects of stimulus-responsive crosslinking and tunable millifluidic assembly (opens in a new tab)

  11. Applications of CFD Simulations on Studying the Multiphase Flow in Microfluidic Devices

    … mass transfer, and reproducibility. Recently, millifluidics has emerged as an alternative since it offers similar control as microfluidics. With its dimensions scaled up to millimeter size, millifluidics saves fabrication efforts and potentially paves the way for industrial applications. Good …

    lsu-thes Repository record for Applications of CFD Simulations on Studying the Multiphase Flow in Microfluidic Devices (opens in a new tab)

  12. Engineering Cardiac Organoid Vascularization via Fluid Shear Stress and Vascular-Promoting Growth Factors

    … factors (GFs). In addition to this study, a millifluidic chip is engineered for shear stress application via flow simulations and experimental flow analysis. We successfully optimized the millifluidic chip to achieve fluid shear stress of 20mPa and validated through particle tracking …

    unt Repository record for Engineering Cardiac Organoid Vascularization via Fluid Shear Stress and Vascular-Promoting Growth Factors (opens in a new tab)

  13. Design and Fabrication of Cephalic Vein Models of End Stage Renal Disease Patients for Hemodynamics Characterization

    … treatment. Our main goal is to develop millifluidic technology that serves as a research tool to study patient-specific hemodynamics in vitro which can potentially help elucidate vascular pathogenesis mechanisms. Here, we elaborate on how we created cephalic vein computational models of …

    chicago Repository record for Design and Fabrication of Cephalic Vein Models of End Stage Renal Disease Patients for Hemodynamics Characterization (opens in a new tab)

  14. Analysis of Bacterial Communities Using Droplets Based Millifluidics

    … of bacterial communities using droplets based millifluidics. To monitor the bacteria growth, we designed an optofluidic system, combining the encapsulation of bacteria in numerous emulsion droplets to monitor their long-term behavior and relationship in a co-culture environment using …

    qucosa-diss Repository record for Analysis of Bacterial Communities Using Droplets Based Millifluidics (opens in a new tab)

  15. Micro- and Milli-fluidic Systems for X-Ray Scattering Analysis of Crystallization Processes

    … development of Xray compatible microfluidic and millifluidic devices and the required data collection and processing strategies to begin to address this deficiency in the study of crystal nucleation and growth. After a thorough review of crystallization theory, microfluidic devices, and previous …

    whiterose Repository record for Micro- and Milli-fluidic Systems for X-Ray Scattering Analysis of Crystallization Processes (opens in a new tab)

  16. Droplet microfluidics: A study of traffic and mass transfer in two-phase microfluidic networks

    … arrays (SDAs). As an example of how modular millifluidic networks can be used as reliable tools for studying droplet traffic, we studied droplet traffic through a modular millifluidic bifurcated loop. We observed the same types of periodic and aperiodic behaviors previously reported with …

    ttu Repository record for Droplet microfluidics: A study of traffic and mass transfer in two-phase microfluidic networks (opens in a new tab)

  17. Designing Tools for Flow Manipulation of Biosamples Spanning Multiple Length Scales

    … size. Finally, a well-plate insert with embedded millifluidic networks is fabricated for gentle, high-throughput sleep-deprivation studies on zebrafish larvae. Together, these studies highlight the versatility of hydrodynamic forces applied within microfluidic and millifluidic systems to address …

    jhu Repository record for Designing Tools for Flow Manipulation of Biosamples Spanning Multiple Length Scales (opens in a new tab) Embargoed until 2030-05-01

  18. SELF-IMMOBILIZED, CROSS-LINKED ENZYME AGGREGATES (CLEAs) FOR BIOCATALYSIS

    … carriers to improve their stability. Firstly, millifluidic reactors with two laminar flows of an enzyme solution and an organic solvent were employed to prepare uniform CLEAs of cellulase and laccase. CLEA had a size between 200 and 400 nm and were highly uniform. They can be collected on …

    nus Repository record for SELF-IMMOBILIZED, CROSS-LINKED ENZYME AGGREGATES (CLEAs) FOR BIOCATALYSIS (opens in a new tab)

Page 1 of 3