Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Minibeam"”
-
Dosimetric studies for proton minibeam radiation therapy
Au cours des dernières décennies, la radiothérapie a bénéficié de nombreuses avancées permettant de conformer une dose très élevée à la tumeur et de réduire la dose délivrée aux tissus normaux. Cependant, la toxicité radio-induite dans les tissus normaux reste l’un des principaux facteurs limitants …
-
Feasibility Study of Single-Gantry-Angle Proton Minibeam Lattice Radiotherapy
… is to investigate the feasibility of Proton Minibeam Lattice Radiation Therapy (pMBLRT) in a clinical setting. The pMBLRT is a 3 dimensional version of Spatially Fractionated Radiation Therapy (SFRT). Clinical trials indicate that the highly heterogeneous dose distribution in a tumor volume …
-
Charged particle minibeam radiation therapy studies using synchrotron-based infrared microspectroscopy
La radioteràpia amb minifeixos de partícules carregades (CP-MBRT) és una modalitat innovadora de RT que combina el fraccionament espacial de la dosi, que augmenta dràsticament la tolerància dels teixits sans a la radiació, amb les propietats radiobiològiques superiors dels feixos de partícules …
-
The Radiochemical Basis of FLASH and Minibeam Radiotherapy: Investigating H2O2 Production and Diffusion
Background: FLASH and minibeam radiotherapy (MBRT) have emerged as promising approaches to enhance the therapeutic ratio in radiation therapy by selectively sparing normal tissues while maintaining effective tumor control. Despite their potential, the underlying radiochemical mechanisms remain …
-
Study of biological mechanisms associated to the response to proton minibeam radiation therapy (pMBRT)
Le cancer demeure l'une des principales causes de mortalité mondiale. S'il peut être traité par chirurgie, chimiothérapie et radiothérapie (RT), certaines tumeurs, notamment cérébrales, restent difficiles à traiter en raison de leur localisation, de leur agressivité et de leur résistance aux …
-
Development of a Minibeam Delivery System for Use with a Radiation Therapy Research Platform
… increasing benefits as the beam size decreases. Minibeam radiation therapy (MBRT) is a form of SFRT with beam sizes on the order of 1 mm, which is achievable utilizing conventional treatment techniques, but MBRT has only recently been used in the treatment of humans. The primary objectives of …
-
Characterization and Validation of a Proton Minibeam System and Evaluation of Treatment Planning Systems
… traditional methods of radiation therapy, proton minibeam radiation therapy (pMBRT) is not currently used clinically. This work attempts to model a pMBRT minibeam and assess the accuracy of Class-II Monte Carlo algorithms in generating clinical treatment plans. This work characterized a collimated …
-
Novel approaches to GRID therapy: Electron GRID and photon minibeams
… beam electron GRID, radioisotope-based photon minibeam GRID, and megavoltage photon minibeam GRID. For each methodology, a combination of Monte Carlo simulation (using the Monte Carlo code MCNP6) and physical measurements (using EBT3 radiochromic film) was used to characterize the dose rate and …
-
Development of 2-3 mm proton minibeams as a new form of GRID radiotherapy
… proton GRID therapy based on an array of proton minibeams developed at the existing proton therapy clinics. The diameter of the proton minibeams is in the range of 2-3 mm. The purpose of this new form of proton GRID therapy is to further enhance normal tissue sparing during the treatment. The …
-
Monte Carlo and experimental small-field dosimetry applied to spatially fractionated synchrotron radiotherapy techniques
… (ESRF): microbeam radiation therapy (MRT) and minibeam radiation therapy (MBRT). The two main distinct characteristics with respect to conventional RT are the use of submillimetric field sizes and spatial fractionation of the dose. This PhD work deals with different features related to …
-
Spatial fractionation of the dose in charged particle therapy
… Parmi ces approches, la technique synchrotron “Minibeam Radiation Therapy” (MBRT) a démontré sa capacité à élever la résistance des tissus sains aux rayonnements, ainsi qu’à induire un important retard de croissance tumorale. La MBRT combine des faisceaux submillimétriques à un fractionnement …
-
Design and optimization of mini-beam GRID and LATTICE therapy using linear accelerators
… radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not …
-
Force Relaxation in Matched Light Titanium and Stainless Steel Wires
… at the midpoint by a steel rod extending from a minibeam load cell. Though 1 mm deflections are commonly placed in these light flexible wires in orthodontic mechanics, the immediate result evidenced was a very high initial force ranging from 528 to 1085 grams depending upon the wire type. This is …
-
Advancing the generation of proton minibeams for radiation therapy
… La proton thérapie avec mini-faisceaux (proton minibeam radiation therapy, pMBRT) est une nouvelle stratégie thérapeutique qui a pour objectif d’améliorer la préservation des tissus sains en combinant les avantages balistiques des protons et le fractionnement spatial de la dose obtenu avec des …
-
New strategies in the treatment of radioresistant tumor cells by using synchrotron radiation and metallic compounds
… en el fraccionament espacial de la dosi, com la Minibeam Radiation Therapy (MBRT), s’han anat desenvolupant en els sincrotrons. Degut a que variacions en les característiques dels feixos en MBRT, ponen donar lloc a efectes biològics completament diferents, experiments in vitro i in vivo són …
-
Applications of particle physics techniques for proton computed tomography
… it at Birmingham's MC40 cyclotron and the proton minibeam radiotherapy centre at the Curie Institue under real clinical conditions, and second by simulating a full pCT system consisting in a DMAPS as proton trackers and a novel range telescope ASTRA (designed during the thesis). The simulation and …
-
A multi-technique hierarchical X-ray phase-based approach for the characterization and quantification of the effects of novel radiotherapies
… the effects of novel RTs, namely Microbeam and Minibeam Radiation therapy (MRT and MB), and to compare them to the standard Broad Beam (BB) induced effects on brain and lungs. MRT and MB are novel radiotherapies that deliver an array of spatially fractionated X-ray beamlets issued from a …
-
Tumeurs cérébrales et rayonnement Synchrotron. Développement méthodologique pour la radiothérapie par minifaisceaux et suivi du traitement par imagerie fonctionnelle
En 2006 Dilmanian et al. ont proposé une méthode d'irradiation par rayonnement synchrotron innovante appelée minifaisceaux. L'irradiation de tumeur par minifaisceaux monochromatiques consiste en un motif fractionné spatialement de faisceaux de rayons X submillimétriques produits par un synchrotron. …
-
Monte Carlo simulation studies for spatially fractionated radiation therapy techniques
… phantom was irradiated with carbon and oxygen minibeams of 0.7 mm of beam width, and with protons in a grid geometry configuration. Several centre-to-centre distances, covering a 2 x 2 cm2 area, have been taken into account. The ratio of the peak-to-valley doses (PVDR) and the penumbrae was …