Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 14 of 14 for “"Minilab"”

  1. MiniLab Metrópole - artefato educacional para experimentos em eletricidade e eletrônica

    … the present work presents the development of the Minilab Metrópole, an innovative portable and low-cost physical device that aggregates the key features of an oscilloscope and a signal generator, in order to be used in electricity experiments and electronics. The research and construction of this …

    brazil-ufrn Repository record for MiniLab Metrópole - artefato educacional para experimentos em eletricidade e eletrônica (opens in a new tab)

  2. Microfluidic Device Fabrication Using Frugal Methods

    … research has focused on glass engraving. The Minilab project is aimed at establishing a biochip fabrication method with a pattern of channels for fluid testing. The selected process uses three microfluidic fabrication concepts: xurography on copper sheet metal, using a transfer stamp, and then …

    santa-clara Repository record for Microfluidic Device Fabrication Using Frugal Methods (opens in a new tab)

  3. A novel laboratory dispersive and distributive minimixer and applications. Development of a new minimixer that can duplicate mixing which occurs in a large twin screw extruder.

    … machines, such as the Thermo Scientific HAAKE Minilab II Micro Compounder which processes on the scale of 7 cm3 of material volume. This can be too small for some needs and therefore a machine is required to produce material on the 10g to 100g scale. To this end a laboratory mixer of novel …

    bradford Repository record for A novel laboratory dispersive and distributive minimixer and applications. Development of a new minimixer that can duplicate mixing which occurs in a large twin screw extruder. (opens in a new tab)

  4. Application of Hot-Melt Extrusion Technology for the Preparation of Carbamazepine Extended-Release Tablets

    … Initial extrusion was carried out using a HAAKE™ Minilab extruder. A USP Type-II dissolution apparatus was utilized to conduct an in vitro drug release study. Lead formulation met the required USP dissolution test specification (10-30% at 2hr; >70% at 24hr) that contains 15% Eudragit® RL PO and 5% …

    mississippi Repository record for Application of Hot-Melt Extrusion Technology for the Preparation of Carbamazepine Extended-Release Tablets (opens in a new tab)

  5. Schmelzextrusion Und Sprühtrocknung als Herstellungsverfahren für risperidonhaltige Implantate und Mikrosphären aus Polylaktid-Co-Polyglykolidsäuren

    … B-290 und der Schmelzextrusion mittels des Haake MiniLab™- und des Thermo Scientific™ Pharma 11-Extruders zur Herstellung von risperidonhaltigen PLGA-Implantaten bzw. Mikrosphären untersucht. Die hergestellten Implantate bzw. Mikrosphären wurden durch verschiedene mechanische, thermische, mikro- …

    cau-kiel Repository record for Schmelzextrusion Und Sprühtrocknung als Herstellungsverfahren für risperidonhaltige Implantate und Mikrosphären aus Polylaktid-Co-Polyglykolidsäuren (opens in a new tab)

  6. Chemical Modification of Polypropylene with Organo-functional Silanes

    … in a co-rotating twin-screw mini-extruder Haake Minilab Microcompounder (Minilab) using a recirculating mode (batch). The grafted products were purified and then studied by Fourier Transform Infrared Spectroscopy (FT-IR) to verify the grafting and compare the grafting efficiencies of those …

    waterloo Repository record for Chemical Modification of Polypropylene with Organo-functional Silanes (opens in a new tab)

  7. Preparation And Evaluation Of Valacyclovir Hydrochloride Ocular Inserts By Hot Melt Extrusion Technique

    … extruded through co – rotating twin-screw Haake MiniLab ThermoFisher ® Scientific extruder. The obtained ocular inserts were cut into dimensions of 4mm×2mm×1mm to have suitable product instillation in the eye. Ocular inserts were evaluated for drug content, weight variation, uniformity of …

    mississippi Repository record for Preparation And Evaluation Of Valacyclovir Hydrochloride Ocular Inserts By Hot Melt Extrusion Technique (opens in a new tab)

  8. Quality and composition of anthelmintic medicines available in Eastern and Western Africa: an \({in-vitro}\) analysis of Albendazole, Mebendazole and Praziquantel

    … tool. Products were then screened with the GPHF Minilab, consisting of tests of mass uniformity, disintegration times and thin-layer chromatography (TLC). Confirmatory tests were performed according to international pharmacopoeiae, applying assays for dissolution profiles and high-performance …

    wurz-thes Repository record for Quality and composition of anthelmintic medicines available in Eastern and Western Africa: an \({in-vitro}\) analysis of Albendazole, Mebendazole and Praziquantel (opens in a new tab)

  9. Evaluation of the Quality of Artemether/Lumefantrine, Sulphadoxine/Pyrimethamine and Quinine Sulphate Tablets in Public and private Health Institutions in Lusaka District

    … of the drugs was ascertained using the GPHF-Minilab at Pharmaceutical Regulatory Authority, and data were entered in Epidata and analysed, and presented in cross tabulations. This study provides objective evidence to answer speculations whether or not substandard antimalarial drugs exist in …

    zambia Repository record for Evaluation of the Quality of Artemether/Lumefantrine, Sulphadoxine/Pyrimethamine and Quinine Sulphate Tablets in Public and private Health Institutions in Lusaka District (opens in a new tab)

  10. PREPARATION AND CHARACTERIZATION OF POLYMER/FERROELECTRIC CERAMIC PARTICLE COMPOSITES FOR ELECTROACTIVE ACTUATION

    … (SEBS) with the use of the Minilab counter-rotating twin screw extruder. Scanning electron microscope (SEM) images showed the dispersion of the fillers in the matrix. Results showed that POSS is much better than OPA as a ligand to approach a homogeneous dispersion. After the …

    ohiolink Repository record for PREPARATION AND CHARACTERIZATION OF POLYMER/FERROELECTRIC CERAMIC PARTICLE COMPOSITES FOR ELECTROACTIVE ACTUATION (opens in a new tab)

  11. Development and Characterization of Hot-melt Extruded Biodegradable Poly(lactide-co-glycolide) Implants

    … biodegradable implants prepared with the Haake MiniLab under extrusion parameters of 85 °C/ 30 rpm and 105 °C/ 120 rpm, an increase in processing temperature and screw speed resulted in extrudates of uneven surface with a so-called “sharkskin effect”. The increased surface area led to a higher …

    fu-berlin Repository record for Development and Characterization of Hot-melt Extruded Biodegradable Poly(lactide-co-glycolide) Implants (opens in a new tab)

  12. Quality analysis of some first-line HIV/AIDS medicines dispensed in Lusaka District Health facilities of Zambia

    … adapted from German Pharm Health Fund (GPHF-minilab) that employs Thin Layer Chromatography (TLC) techniques at Tejay Pharmaceutical Laboratories in Lusaka, Zambia. A total of eleven drug samples were assayed and analyzed.The analytical tests that were performed included: the identification …

    zambia Repository record for Quality analysis of some first-line HIV/AIDS medicines dispensed in Lusaka District Health facilities of Zambia (opens in a new tab)

  13. The Environmental Impact Of The Retail Photoprocessing Industry In Santa Clara County: 1996 Vs. 2006

    Consumer digital cameras appeared on the market in 1994. Consequently, the photoprocessing industry experienced a downturn beginning in 2000, with a sudden drop in activity. This study focuses on the evolution of the retail photoprocessing industry between 1996 and 2006 and evaluates its four major …

    sjsu Repository record for The Environmental Impact Of The Retail Photoprocessing Industry In Santa Clara County: 1996 Vs. 2006 (opens in a new tab)

  14. Entwicklung vereinfachter flüssigchromatographischer Untersuchungsmethoden zur Qualitätskontrolle essentieller Antimalaria-Medikamente in Entwicklungs- und Schwellenländern

    … wie beispielsweise die im GPHF-Minilab® angewandte Dünnschichtchromatographie, erfordern im Vergleich zur HPLC weniger komplexe und teure Instrumente und können selbst in entlegenen Gebieten ohne Laboratorium durchführt werden. Sie verfügen allerdings über eine nur sehr geringe …

    wurz-thes Repository record for Entwicklung vereinfachter flüssigchromatographischer Untersuchungsmethoden zur Qualitätskontrolle essentieller Antimalaria-Medikamente in Entwicklungs- und Schwellenländern (opens in a new tab)