Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"Minimal calibration"”

  1. Semi-supervised training for infrastructure mediated sensing: disaggregated hot and cold water sensing with minimal calibration

    … necessitating that each residence go through a calibration process. I formalize this calibration process using semi-supervised techniques such as expert knowledge through a rule-based classifier, co-training, and virtual evidence. I evaluate the system in several studies, including a …

    washington Repository record for Semi-supervised training for infrastructure mediated sensing: disaggregated hot and cold water sensing with minimal calibration (opens in a new tab)

  2. Calibration-free ion-selective electrodes and theoretical insights and practical applications of ionic liquid references

    … of ion-selective electrodes (ISEs) for calibration-free and long-term stability (Ch. 2). The second is the development of reference electrodes by using ionic liquid doped polydimethylsiloxane (PDMS) reference membranes and colloid-imprinted mesoporous (CIM) carbon as solid contact (Ch. …

    umn Repository record for Calibration-free ion-selective electrodes and theoretical insights and practical applications of ionic liquid references (opens in a new tab)

  3. Efficient Development of Density-Insensitive Near-Infrared Methods for In-Line Drug Content Monitoring in Continuous Powder Streams

    … modeling strategies that reduce the current calibration burden and ensure model insensitivity to the physical variations in CM systems are needed. In this dissertation, powder density is identified as an underlying source of spectral variance due to flow rate and used to develop …

    duquesne Repository record for Efficient Development of Density-Insensitive Near-Infrared Methods for In-Line Drug Content Monitoring in Continuous Powder Streams (opens in a new tab)

  4. Ultrasound Based Dynamic Reference Reflection Technique for Simultaneous Specific Gravity and Temperature Estimation

    … of signal quality to enable operation under minimal gain thus eliminating noise and later this device design leads up to a new discovery wherein the preconceived notion of sound interaction at solid-fluid boundary is corrected and an empirical relation is derived for this interaction. Using …

    usf Repository record for Ultrasound Based Dynamic Reference Reflection Technique for Simultaneous Specific Gravity and Temperature Estimation (opens in a new tab)

  5. Assessing the combined effect of Carbon-Water dynamics on hydrological processes in Brazil

    … root dynamics in the success of the model; the minimal calibration needed per site reflects the strong physiological understanding behind it. Finally, we show declines in ET across an increasing atmospheric CO<sub>2</sub> gradient, with dampened impacts on hydrological processes through …

    bristol Repository record for Assessing the combined effect of Carbon-Water dynamics on hydrological processes in Brazil (opens in a new tab)

  6. A Study of Battery State-of-health Tracking Using an Extended Kalman Filter and Randle's Battery Circuit Model

    … during the state-of-health measurement; 2) minimal calibration required for each battery model; 3) state-of-health measurements can be obtained in less than two hours; and 4) state-of-health must be within 2% accuracy based the IEEE performance test. Traditional methods and some alternative …

    sdstate Repository record for A Study of Battery State-of-health Tracking Using an Extended Kalman Filter and Randle's Battery Circuit Model (opens in a new tab)

  7. Retrodirective phased array antenna for nanosatellites

    … of the front-end electronics show that with minimal calibration, the beamforming and scanning error can be reduced to 5°. The power consumption and signal gain of the electronics is also verified through testing. The CubeSat Communications Platform, a CubeSat mission funded through the Air …

    alaska Repository record for Retrodirective phased array antenna for nanosatellites (opens in a new tab)

  8. Development of Capacitive Wearable Sensors for Limb Volume Measurement Towards Swelling Management

    … based on superior linearity characteristics, minimal drift properties, and enhanced compatibility with wearable electronics applications. Direct ink writing (DIW) fabrication processes were systematically optimized for IDE sensor production, incorporating thermoplastic polyurethane (TPU) …

    waterloo Repository record for Development of Capacitive Wearable Sensors for Limb Volume Measurement Towards Swelling Management (opens in a new tab)

  9. An approach for modelling snowcover ablation and snowmelt runoff in cold region environments

    … snowcover ablation and snowmelt runoff with minimal calibration. Verification of this approach in an arctic basin illustrated that landscape based parameters are a feasible regionalisation framework for distributed and physically based models. In summary, the proposed modelling philosophy, …

    sask Repository record for An approach for modelling snowcover ablation and snowmelt runoff in cold region environments (opens in a new tab)

  10. Three Essays On Foreign Exchange Options

    … OTC FX options can be accurately priced with minimal calibration. I further extend the model to allow autoregressive conditional Poisson jumps and multiple factors in the interest rates to handle the latent interest factors in Chapter 4. I propose to adjust the discrete time-step size to price …

    durham Repository record for Three Essays On Foreign Exchange Options (opens in a new tab)

  11. Wettability assessment using resistivity and NMR measurements

    … assessment from resistivity measurements with minimal calibration efforts. Moreover, a new method for interpretation of 2D NMR maps is introduced to simultaneously estimate water saturation and wettability. Finally, this thesis introduces an integrated inversion workflow for joint …

    texas Repository record for Wettability assessment using resistivity and NMR measurements (opens in a new tab)

  12. Distinguishing carbonate reservoir pore facies with nuclear magnetic resonance as an aid to identify candidates for acid stimulation

    … genetic pore types from NMR logs with minimal calibration against borehole cores and will help predict the spatial distribution of poroperm facies in complex carbonate reservoirs with much improved accuracy.

    tamu Repository record for Distinguishing carbonate reservoir pore facies with nuclear magnetic resonance as an aid to identify candidates for acid stimulation (opens in a new tab)

  13. Voltage reference/incremental data converter designs for low-cost CMOS temperature sensor

    … sensor with small form factor, low power and minimal calibration effort are the main requirements for high-volume deployment; yet existing temperature sensor solutions heavily rely on overhead circuits and/or calibration to achieve the target requirements, leading to high cost.</p> <p>In this …

    hkust Repository record for Voltage reference/incremental data converter designs for low-cost CMOS temperature sensor (opens in a new tab)

  14. Design, implementation, and evaluation of novel fault detection methodologies for time varying industrial mechanical systems

    … developed in this work emphasize adaptability, minimal calibration, and real-world applicability. The thesis begins with a detailed examination of industrial mechanical systems and a critical review of existing fault detection methods, particularly those targeting mechanical unbalance, gear …

    barcelona Repository record for Design, implementation, and evaluation of novel fault detection methodologies for time varying industrial mechanical systems (opens in a new tab) Embargoed

  15. Design of an Affordable, Precise Irrigation Controller that Lowers the Barrier to Water- and Energy-Sustainable Agriculture

    … more reliable irrigation using solar power, with minimal battery usage. High reliability at low cost necessitates that the POWEIr controller’s irrigation schedules are robust to errors in agronomy inputs and weather data. Sensitivity to these errors was assessed by evaluating the impact on …

    mit Repository record for Design of an Affordable, Precise Irrigation Controller that Lowers the Barrier to Water- and Energy-Sustainable Agriculture (opens in a new tab)

  16. Investigation of low coherence interferometry techniques for biomedical applications

    … an object in the optical trap. Extensive initial calibration is needed before accurate positional measurements can be made. A LCI system, on the other hand, can provide accurate axial measurements with minimal calibration. A common-path LCI system was incorporated into an optical tweezers system. …

    nanyang Repository record for Investigation of low coherence interferometry techniques for biomedical applications (opens in a new tab)

  17. Enhancing the Decoding Performance of Steady-State Visual Evoked Potentials based Brain-Computer Interface

    … (UI) training scenario as this will lead to a minimal calibration system and provide the ability to run inference in a plug-and-play mode. The proposed methods were evaluated on a 7-class SSVEP dataset collected on 21 healthy participants (Dataset 1). The UI method was also assessed on a …

    waterloo Repository record for Enhancing the Decoding Performance of Steady-State Visual Evoked Potentials based Brain-Computer Interface (opens in a new tab)

  18. Numerical Simulation of Hydrocarbon Fuel Dissolution and Biodegradation in Groundwater

    … and mass balance errors for all phases are minimal. The model is first applied to simulate a pilot scale diesel fuel dissolution experiment in which humic acid is used as a natural organic carrier to enhance dissolution and to promote biodegradation of the aqueous components. The pilot scale …

    waterloo Repository record for Numerical Simulation of Hydrocarbon Fuel Dissolution and Biodegradation in Groundwater (opens in a new tab)

Page 1 of 2