Results 1 to 20 of 50 for “"Mock Circulatory"”
-
MULTI-SCALE MODELING OF THE FONTAN CIRCULATION USING A MOCK CIRCULATORY SYSTEM
… been modeled experimentally using an adjustable mock circulatory system, which for the first time includes the influence of respiration. A multi-scale model based on a realistic, 3D patient-specific test section coupled with a lumped parameter model tuned to patient-specific parameters is used to …
-
Design and implementation of a mock circulatory system for the evaluation of left ventricular assist devices
… device (LVAD) it is necessary to test it in a mock circulatory system (MCS). An MCS should behave much like a cardiovascular system (CVS) in terms of similar physical parameters and operating conditions. The goal of this thesis is to create an MCS that closely mimics the desired impedance and …
-
MODERNIZATION OF THE MOCK CIRCULATORY LOOP: ADVANCED PHYSICAL MODELING, HIGH PERFORMANCE HARDWARE, AND INCORPORATION OF ANATOMICAL MODELS
A systemic mock circulatory loop plays a pivotal role as the in vitro assessment tool for left heart medical devices. The standard design employed by many research groups dates to the early 1970's, and lacks the acuity needed for the advanced device designs currently being explored. The necessity …
-
IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP
… valve using flow visualization techniques in a mock circulatory loop. The mechanical heart valve chosen for this research was a size 17 mm Bjork-Shiley tilting disc valve, as this is a common size valve used for younger patients with smaller cardiovascular anatomy. The mock circulatory loop used …
-
In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop
… using a novel test chamber within an automated mock circulatory loop. The constructed mock loop was designed to maintain consistency of current industrial and academic research systems while providing innovative loop component control that allows for run-time changes and performance screening to …
-
Left Ventricle Assist Device
… research paper highlights the significance of mock circulatory loops in aiding the development and testing of left ventricle assist devices (LVADs). Heart disease is the leading cause of death in America, and LVAD offers an effective solution to patients with severe coronary artery disease who …
-
Development of a Cardiovascular Simulator Incorporating a Phantom Simulation of the Arterial System
A mock circulatory loop was constructed to test a new blood pressure device under development. The loop was intended to replicate a range of cardiac conditions with the implementation of an artificial arterial tree. An in-depth literature review was conducted on the previous construction on mock …
-
Development of a physiologic ex vivo vessel perfusion system.
… become the primary form of implanted mechanical circulatory support (MCS) due to their smaller size, higher energy efficiency, longer durability, and fewer LVAD-related complications when compared to pulsatile flow VADs. However, continuous and pulsatile flows may elicit different cellular and …
-
Evaluation of the nonlinear dynamics of human aortas for material characterization
… and viscoelastic material characterizations. A mock circulatory loop was built to reproduce physiological cardiac pulsatile conditions for the aorta ex-vivo, and obtain the viscoelastic parameters with fluid-structure interactions. Then, specimens were dissected into the three constituent …
-
Use of a laboratory computer for the hydro-dynamic evaluation of aortic valve prostheses in-vitro
… The prostheses were tested in a closed-circuit mock circulatory loop which was designed to approximate physiological pressure and flow behavior near the valve. As operative technique may preserve the sinuses of Valsalva intact or, more commonly, effectively destroy them, the valves were tested …
-
Evaluation of the Hemodynamic Response of Heartbeat Synchronized Speed Modulation using a Continuous Flow Left Ventricular Assist Device
… physiological pulsatile flow of the heart and circulatory system. This causes complications including but not limited to internal bleeding, and increased chance of thrombosis and stroke. An artificial pulsatile flow can be created with a continuous flow LVAD by increasing and decreasing its …
-
A Cost-Effective Method for Fabricating Prosthetic Valves for Patient-Specific In-Vitro Studies
… image velocimetry (PIV) in tandem with a mock circulatory loop (MCL). Although this system enables direct experimentation and evaluation of patient-specific hemodynamics, challenges remain, particularly limited access to real transcatheter valves. There are significant external barriers to …
-
DESIGN & DEVELOPMENT OF HETEROTOPIC TRANSCATHETER TRICUSPID VALVES TO AMELIORATE TRICUSPID REGURGITATION
… characteristics of these valves were tested in a mock circulatory system (MCS) which emulated the patho-physiological pressure and flow conditions. Particle image velocimetry was used to study the flow characteristics in the MCS.
-
Development of a suction detection system for a motorized pulsatile blood pump
… toroidal pulsatile blood pump and a closed loop circulatory system. Together, they predict the pump's motor current traces that reflect ventricular suck-down and provide insights into torque magnitudes that the pump experiences. In addition, the model investigates likeliness of a suction event …
-
Flow visualization studies of a left ventricular bypass pump
… were made of operating, transparent pumps in a mock circulatory loop with a blood analogue fluid. Regions of pump stasis, low velocity flows, and eddy formation were identified. In -redesigning the bypass pump, several changes were implemented that stemmed from these flow visualization studies. …
-
Microprocessor control of a combined assist system for the profound support of the failing heart
Conventional non-invasive mechanical circulatory assist methods such as intra-aortic balloon pumping are of little effectiveness in cases of severe ventricular failure. The proposed study is concerned with the development and testing, on a mock circulatory loop and in a series of dog experiments, …
-
Noninvasive Detection of Central Venous Waveform Using Photoplethysmography
… of the sensor was tested in-vitro using a mock circulatory loop and was also tested on a single human subject. The results from the tests indicated a very good sensor response in estimating pressure waveforms.
Page 1 of 3