Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 26 for “"Mock Circulatory Loop"”.
-
MODERNIZATION OF THE MOCK CIRCULATORY LOOP: ADVANCED PHYSICAL MODELING, HIGH PERFORMANCE HARDWARE, AND INCORPORATION OF ANATOMICAL MODELS
A systemic mock circulatory loop plays a pivotal role as the in vitro assessment tool for left heart medical devices. The standard design employed by many research groups dates to the early 1970's, and lacks the acuity needed for the advanced device designs currently being explored. The necessity …
-
IN VITRO VISUALIZATION OF PEDIATRIC SIZED MECHANICAL HEART VALVE PERFORMANCE USING AORTIC ROOT MODEL IN MOCK CIRCULATORY LOOP
… valve using flow visualization techniques in a mock circulatory loop. The mechanical heart valve chosen for this research was a size 17 mm Bjork-Shiley tilting disc valve, as this is a common size valve used for younger patients with smaller cardiovascular anatomy. The mock circulatory loop used …
-
In Vitro Evaluation of Mechanical Heart Valve Performance Using a Novel Test Chamber in an Automated Mock Circulatory Loop
… using a novel test chamber within an automated mock circulatory loop. The constructed mock loop was designed to maintain consistency of current industrial and academic research systems while providing innovative loop component control that allows for run-time changes and performance screening to …
-
Left Ventricle Assist Device
… research paper highlights the significance of mock circulatory loops in aiding the development and testing of left ventricle assist devices (LVADs). Heart disease is the leading cause of death in America, and LVAD offers an effective solution to patients with severe coronary artery disease who …
-
Use of a laboratory computer for the hydro-dynamic evaluation of aortic valve prostheses in-vitro
… The prostheses were tested in a closed-circuit mock circulatory loop which was designed to approximate physiological pressure and flow behavior near the valve. As operative technique may preserve the sinuses of Valsalva intact or, more commonly, effectively destroy them, the valves were tested …
-
Evaluation of the Hemodynamic Response of Heartbeat Synchronized Speed Modulation using a Continuous Flow Left Ventricular Assist Device
… physiological pulsatile flow of the heart and circulatory system. This causes complications including but not limited to internal bleeding, and increased chance of thrombosis and stroke. An artificial pulsatile flow can be created with a continuous flow LVAD by increasing and decreasing its …
-
A Cost-Effective Method for Fabricating Prosthetic Valves for Patient-Specific In-Vitro Studies
… image velocimetry (PIV) in tandem with a mock circulatory loop (MCL). Although this system enables direct experimentation and evaluation of patient-specific hemodynamics, challenges remain, particularly limited access to real transcatheter valves. There are significant external barriers to …
-
Development of a physiologic ex vivo vessel perfusion system.
… become the primary form of implanted mechanical circulatory support (MCS) due to their smaller size, higher energy efficiency, longer durability, and fewer LVAD-related complications when compared to pulsatile flow VADs. However, continuous and pulsatile flows may elicit different cellular and …
-
Development of a suction detection system for a motorized pulsatile blood pump
… of a toroidal pulsatile blood pump and a closed loop circulatory system. Together, they predict the pump's motor current traces that reflect ventricular suck-down and provide insights into torque magnitudes that the pump experiences. In addition, the model investigates likeliness of a suction …
-
Flow visualization studies of a left ventricular bypass pump
… were made of operating, transparent pumps in a mock circulatory loop with a blood analogue fluid. Regions of pump stasis, low velocity flows, and eddy formation were identified. In -redesigning the bypass pump, several changes were implemented that stemmed from these flow visualization studies. …
-
Microprocessor control of a combined assist system for the profound support of the failing heart
Conventional non-invasive mechanical circulatory assist methods such as intra-aortic balloon pumping are of little effectiveness in cases of severe ventricular failure. The proposed study is concerned with the development and testing, on a mock circulatory loop and in a series of dog experiments, …
-
Noninvasive Detection of Central Venous Waveform Using Photoplethysmography
… of the sensor was tested in-vitro using a mock circulatory loop and was also tested on a single human subject. The results from the tests indicated a very good sensor response in estimating pressure waveforms.
-
Development of a Cardiovascular Simulator Incorporating a Phantom Simulation of the Arterial System
A mock circulatory loop was constructed to test a new blood pressure device under development. The loop was intended to replicate a range of cardiac conditions with the implementation of an artificial arterial tree. An in-depth literature review was conducted on the previous construction on mock …
-
Development of an Automatic Speed Modulation Control for Next Generation LVAD Based on Real-Time Cardiac Activity Monitoring
… evaluated using a previously validated numerical mock circulatory loop (nMCL) coupled with a detailed LVAD model, with simulations conducted across activity states including sleep, rest, and light exercise. Comparative analysis demonstrated that the speed modulation algorithm improved circulatory …
-
The impact of patient-specific vascular structure on localized cooling in the human heart
… left main coronary artery (LMCA) models. A mock circulatory loop was used to determine the exiting temperatures of a standard 7 Fr catheter to feed into our model with flow rates ranging from 29.2 ml/min to 68.85 ml/min. Our work showed that therapeutic hypothermia (TH) temperatures were …
-
In-vitro hydrodynamic evaluation of aortic valve protheses
A mock circulatory loop was designed for the hydrodynamic evaluation of aortic valve prostheses. It had features of low priming volume (1 to 1.2 liters) and its fluid was protected from direct contact with air. The prostheses were mounted in the anatomic subcoronary position of a plexiglas model of …
-
Development of a synthetic trileaflet aortic valve prosthesis
… shaped simulated sinuses. Preliminary mock loop testing of this valve indicates excellent performance. The intact polyurethane valves are attractive candidates for incorporation into the left ventricular bypass pumps under development at Rice and Baylor. Trileaflet valves were …
-
Miniature Axial Flow Blood Pump: Hydraulic Development & Design
… for in vitro hemodynamic evaluation. This mock circulatory loop experiment found that a pump that exhibits a small change in flow for a large change in pressure works better with the failing left ventricle when implanted from the left atrium to the arterial circulation than a pump that …
-
The development and investigation of a novel pulsatile heart assist device
… activation under in vitro conditions. A human mock circulatory loop (MCL) with systemic and coronary perfusion was constructed, capable of simulating various degrees of heart failure. Two prototypes of the CIMS balloon pump were made with varying stiffness. Several experimental factors (balloon …
-
Computational Fluid Dynamics Analysis of Rotating Machinery – Fontan Cavopulmonary Assist Device and Hole Pattern Seals
… were measured using a blood surrogate in a mock circulatory loop and simulated with various turbulence models. Recommendations for the appropriate RANS turbulence models to accurately predict pressure head and shear stress for the Fontan CPAD were made in this study. The hemolytic potential …
Page 1 of 2