Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 22 for “"Model Observers"”.

  1. Red Blood Cell Image Classification Using Model Observers

    Healthy red blood cells (RBCs) undergo a gradual morphological transformation during storage. From original healthy discocytes, RBCs gradually lose membrane surface area and cell volume, eventually turning into ghost (lysed cell). The degree of deterioration varies from cell to cell. These cells …

    houston Repository record for Red Blood Cell Image Classification Using Model Observers (opens in a new tab)

  2. Visual-Search Model Observers in Assessing CT Acquisition Parameters

    … has been dedicated to developing mathematical model observers to be used instead of humans in such studies. In this dissertation, we aimed to develop a novel model observer called the visual-search (VS) observer that could be used as a surrogate to human observers. To evaluate the effectiveness …

    houston Repository record for Visual-Search Model Observers in Assessing CT Acquisition Parameters (opens in a new tab)

  3. Model observers for predicting human performance on signal detection tasks.

    Various model observers have been applied to the objective assessment of medical image quality. However, the relevance of this application to clinical efficacy depends largely on how well model observers predict human performance. Attempting to answer this question, this dissertation focuses on the …

    arizona-thes Repository record for Model observers for predicting human performance on signal detection tasks. (opens in a new tab)

  4. An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations

    Model observers (e.g., the channelized Hotelling observer (CHO)) have been widely used in medical imaging to assess image quality. The CHO consists of the Hotelling observer applied to the outputs of a channel model. The CHO performance is affected by deviations of the input data (i.e., channel …

    jhu Repository record for An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations (opens in a new tab)

  5. Assessment of reconstructed images

    … variety of detection strategies, referred to as model observers. A number of psychophysical experiments have been conducted with the dual purpose of testing factors that influence human detection performance and providing a set of data for assessing the ability of different model observers to …

    arizona-thes Repository record for Assessment of reconstructed images (opens in a new tab)

  6. Task-Based Image Quality Assessment in X-Ray Computed Tomography

    … task-based image quality measurements using model observers were used to evaluate the performance of X-Ray CT systems. To evaluate the dose reduction ability, detection tasks as well as combined detection and estimation tasks were considered. In detection tasks and combined detection and …

    arizona-thes Repository record for Task-Based Image Quality Assessment in X-Ray Computed Tomography (opens in a new tab)

  7. Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images

    … the generalisability of a deep learning model observer, validated to detect nodules, to images of an anthropomorphic phantom with synthetic nodules and whether its detection performance changed with tube voltage ranging from 65 to 125 kVp, and phantom thickness simulated by 0 – 10 cm …

    salford Repository record for Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images (opens in a new tab)

  8. Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer

    … psychophysical studies are resource intensive, model observers are widely used as a surrogate in task-based assessment of image quality. Model observers are typically designed to detect at most one abnormality, e.g., a single lesion. However, in clinical practice, there may be multiple …

    texas Repository record for Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer (opens in a new tab)

  9. Visual target detection under multiple dimensions of uncertainty

    … performance. This thesis aims to measure and model human performance under multiple simultaneous dimensions of uncertainty. I primarily focus on the detection of additive targets in white noise. First, human performance was measured under simultaneous target amplitude, and background contrast …

    texas Repository record for Visual target detection under multiple dimensions of uncertainty (opens in a new tab)

  10. Effects of Gender and Gaze Direction on the Visual Exploration of Male and Female Bodies

    … study used eye-tracking to investigate whether a model’s gaze direction influences the way observers look at the entire body of the model and how this interacts with the observer and the model’s gender. Participants viewed individual male and female computer agents during both a free-viewing task …

    waterloo Repository record for Effects of Gender and Gaze Direction on the Visual Exploration of Male and Female Bodies (opens in a new tab)

  11. Attenuation, noise, and image quality in single-photon emission computed tomography

    … attenuating medium, the attenuation problem is modelled by the exponential Radon transform. In this dissertation, we mathematically describe the three, previously published, analytical inverses to this forward problem, known as the methods of Bellini, Inouye, and Tretiak & Metz. Also included …

    arizona-thes Repository record for Attenuation, noise, and image quality in single-photon emission computed tomography (opens in a new tab)

  12. Task-based lens design, with application to digital mammography

    Recent advances in model observers that predict human perceptual performance now make it possible to optimize medical imaging systems for human task performance. We illustrate the procedure by considering the design of a lens for use in an optically coupled digital mammography system. The …

    arizona-thes Repository record for Task-based lens design, with application to digital mammography (opens in a new tab)

  13. Anthropomorphic Model for Medical Image Quality Assessment

    … evaluation of an anthropomorphic visual search model observer. The model incorporates a novel threshold mechanism inspired by human visual system principles, particularly emphasizing the selective processing of high-salience features. This mechanism aims to enhance discrimination performance by …

    houston Repository record for Anthropomorphic Model for Medical Image Quality Assessment (opens in a new tab) Embargoed until 2027-05-01

  14. Task-based Imaging Performance in 3D X-Ray Tomography: Noise, Detectability, and Implications for System Design

    … dose, detector design, background anatomy, model observers, and the imaging task. The metrology throughout includes Fourier domain descriptors of spatial resolution (modulation transfer function, MTF), noise (noise-power spectrum, NPS), noise-equivalent quanta (NEQ), and task-based …

    toronto-retro Repository record for Task-based Imaging Performance in 3D X-Ray Tomography: Noise, Detectability, and Implications for System Design (opens in a new tab)

  15. Task-Based Assessment and Optimization of Digital Breast Tomosynthesis

    … patients/phantoms to the imaging hardware to the model observers used to measure signal detectability. The main focus, however, is on quantifying tradeoffs between three key parameters that affect image quality: (1) scan angle, (2) number of projections, and (3) exposure. We show that in …

    arizona-thes Repository record for Task-Based Assessment and Optimization of Digital Breast Tomosynthesis (opens in a new tab)

  16. TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY

    … strategies and a variety of mathematical model observers in order to evaluate the performance of clinical FFDM systems under different conditions. To evaluate image acquisition performance, we tested a system-model-based Hotelling observer (SMHO) model on a bench-top system using a uniform …

    maryland Repository record for TASK SPECIFIC EVALUATION METHODOLOGY FOR CLINICAL FULL FIELD DIGITAL MAMMOGRAPHY (opens in a new tab)

  17. The behavioral and neural mechanisms of the social transmission of information and behavior

    … into this topic conducted using rat models of social learning. A specific emphasis is placed on the social transmission of food preference (STFP) model, in which a naïve observer rat acquires a preference for a food through interaction with a conspecific demonstrator that has recently …

    texas Repository record for The behavioral and neural mechanisms of the social transmission of information and behavior (opens in a new tab)

  18. High-throughput visual knowledge analysis and retrieval in big data ecosystems

    … measured spatially and temporally to model observers' cognitive process. These gaze patterns are then indexed in a NoSQL distributed database as a visual knowledge repository, which is accessed using various unique retrieval methods developed through this dissertation work. To provide …

    missouri Repository record for High-throughput visual knowledge analysis and retrieval in big data ecosystems (opens in a new tab)

  19. TOWARDS FURTHER OPTIMIZATION OF RECONSTRUCTION METHODS FOR DUAL-RADIONUCLIDE MYOCARDIAL PERFUSION SPECT

    … on simulations of realistic patients population modeling existing hardware and previously optimized dual-isotope simultaneous-acquisition imaging protocols. After optimization, the two algorithms were compared to determine the optimal reconstruction methods for MPS. First, we developed a model …

    jhu Repository record for TOWARDS FURTHER OPTIMIZATION OF RECONSTRUCTION METHODS FOR DUAL-RADIONUCLIDE MYOCARDIAL PERFUSION SPECT (opens in a new tab)

  20. Virtual Clinical Trials in PET Imaging for Improved Diagnosis of and Evaluation of Therapies for Cancer

    … were combined, including radiotracer kinetic modeling, data generation simulations, image reconstruction algorithms, and human and model observer analyses. Improved understanding of parameters can be used to inform the design of prospective clinical trials to improve detection of tumors and …

    washington Repository record for Virtual Clinical Trials in PET Imaging for Improved Diagnosis of and Evaluation of Therapies for Cancer (opens in a new tab)

Page 1 of 2