Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 26 for “"Model observer"”

  1. Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer

    … they can be optimally interpreted by a trained observer, e.g., a radiologist. Start-of-art medical image quality is measured by the performance of an observer on a given clinical task. Since psychophysical studies are resource intensive, model observers are widely used as a surrogate in …

    texas Repository record for Model observer for optimizing digital breast tomosynthesis for detection of multifocal and multicentric breast cancer (opens in a new tab)

  2. Task-based image quality assessment in radiation therapy

    … demonstrate a robust, fully computer simulated model observer. This observer utilizes images of known objects to simulate end-to-end radiation therapy treatments, and subsequently evaluates treatments in terms of patient outcome. Thus image quality is linked directly to patient treatment …

    missouri Repository record for Task-based image quality assessment in radiation therapy (opens in a new tab)

  3. An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations

    Model observers (e.g., the channelized Hotelling observer (CHO)) have been widely used in medical imaging to assess image quality. The CHO consists of the Hotelling observer applied to the outputs of a channel model. The CHO performance is affected by deviations of the input data (i.e., channel …

    jhu Repository record for An Investigation of Strategies for Applying Model Observers to Small Ensembles of Realistically Simulated Medical Images from Patient Populations Modeling Background and Signal Variations (opens in a new tab)

  4. Task-based Optimization of Administered Activity for Pediatric Renal SPECT Imaging

    … we have developed a projection image database modeling imaging of 99mTc-DMSA, a renal function agent. The database uses a highly-realistic population of pediatric phantoms with anatomical and body morphological variations. Using the developed projection image database, we have explored patient …

    jhu Repository record for Task-based Optimization of Administered Activity for Pediatric Renal SPECT Imaging (opens in a new tab)

  5. TOWARDS FURTHER OPTIMIZATION OF RECONSTRUCTION METHODS FOR DUAL-RADIONUCLIDE MYOCARDIAL PERFUSION SPECT

    … on simulations of realistic patients population modeling existing hardware and previously optimized dual-isotope simultaneous-acquisition imaging protocols. After optimization, the two algorithms were compared to determine the optimal reconstruction methods for MPS. First, we developed a model …

    jhu Repository record for TOWARDS FURTHER OPTIMIZATION OF RECONSTRUCTION METHODS FOR DUAL-RADIONUCLIDE MYOCARDIAL PERFUSION SPECT (opens in a new tab)

  6. Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images

    … factors. A further challenge is the variation of observer methodologies used in optimisation studies which produce ambiguous tube voltage recommendations.To address these challenges, the aim of this thesis is to investigate the agreement between task-based image quality of visually perceived …

    salford Repository record for Optimisation in digital radiography: Bridging the gap between image data quality and visual perception of anthropomorphic images (opens in a new tab)

  7. Flux and speed estimation techniques for sensorless control of induction motors

    … to low-speed flux estimation when a Voltage Model observer is used. Pure integration cannot be implemented due to offsets in the measured signals and integrators must be replaced by low pass filters. At low speed, the flux estimates are incorrect in both magnitude and angle; consequently, the …

    ohiolink Repository record for Flux and speed estimation techniques for sensorless control of induction motors (opens in a new tab)

  8. Social Learning of Employee Engagement

    … relationship between engagement levels of role models and observing employees. Results revealed some truly validating insights, primarily confirming the influence of coworkers on employee engagement. Model type (i.e., manager vs. non-manager) as well as relationship satisfaction were explored …

    loyola-thes Repository record for Social Learning of Employee Engagement (opens in a new tab)

  9. Signal detection in lumpy backgrounds

    … dissertation we explore signal detection with model and human observers in the setting of nuclear medicine. Regarding the model observer, the main focus is on the linear observer that maximizes detectability, which we call the Hotelling observer. In particular, we outline two methods for …

    arizona-thes Repository record for Signal detection in lumpy backgrounds (opens in a new tab)

  10. Staging Liver Fibrosis with Statistical Observers

    … training and testing images for a Hotelling observer are covered. An observer based on local texture analysis is trained and tested using wet-tissue phantoms. The technique is used to optimize the MRI sequence based on task performance. The final method developed is a two stage model observer …

    arizona-thes Repository record for Staging Liver Fibrosis with Statistical Observers (opens in a new tab)

  11. Task-based lens design, with application to digital mammography

    Recent advances in model observers that predict human perceptual performance now make it possible to optimize medical imaging systems for human task performance. We illustrate the procedure by considering the design of a lens for use in an optically coupled digital mammography system. The …

    arizona-thes Repository record for Task-based lens design, with application to digital mammography (opens in a new tab)

  12. Red Blood Cell Image Classification Using Model Observers

    Healthy red blood cells (RBCs) undergo a gradual morphological transformation during storage. From original healthy discocytes, RBCs gradually lose membrane surface area and cell volume, eventually turning into ghost (lysed cell). The degree of deterioration varies from cell to cell. These cells …

    houston Repository record for Red Blood Cell Image Classification Using Model Observers (opens in a new tab)

  13. Anthropomorphic Model for Medical Image Quality Assessment

    … evaluation of an anthropomorphic visual search model observer. The model incorporates a novel threshold mechanism inspired by human visual system principles, particularly emphasizing the selective processing of high-salience features. This mechanism aims to enhance discrimination performance by …

    houston Repository record for Anthropomorphic Model for Medical Image Quality Assessment (opens in a new tab) Embargoed until 2027-05-01

  14. Model observers for predicting human performance on signal detection tasks.

    Various model observers have been applied to the objective assessment of medical image quality. However, the relevance of this application to clinical efficacy depends largely on how well model observers predict human performance. Attempting to answer this question, this dissertation focuses on the …

    arizona-thes Repository record for Model observers for predicting human performance on signal detection tasks. (opens in a new tab)

  15. Visual-Search Model Observers in Assessing CT Acquisition Parameters

    … In a task-based image quality assessment, an observer such as a radiologist is to read an ensemble of images that are produced using different imaging systems or using the same system but with different parameters. An example of a task can be lesion detection. Then the performance of the …

    houston Repository record for Visual-Search Model Observers in Assessing CT Acquisition Parameters (opens in a new tab)

  16. Virtual Clinical Trials in PET Imaging for Improved Diagnosis of and Evaluation of Therapies for Cancer

    … were combined, including radiotracer kinetic modeling, data generation simulations, image reconstruction algorithms, and human and model observer analyses. Improved understanding of parameters can be used to inform the design of prospective clinical trials to improve detection of tumors and …

    washington Repository record for Virtual Clinical Trials in PET Imaging for Improved Diagnosis of and Evaluation of Therapies for Cancer (opens in a new tab)

  17. Cultural differences in the decoding and representation of facial expression signals

    … Asian (EA) recognition deficit. Specifically, EA observers consistently perform significantly poorer when categorising certain ‘universal’ facial expressions compared to Western Caucasian (WC) observers – a surprisingly neglected finding given the importance of emotion communication for human …

    glasgow Repository record for Cultural differences in the decoding and representation of facial expression signals (opens in a new tab)

  18. Task-based Imaging Performance in 3D X-Ray Tomography: Noise, Detectability, and Implications for System Design

    … dose, detector design, background anatomy, model observers, and the imaging task. The metrology throughout includes Fourier domain descriptors of spatial resolution (modulation transfer function, MTF), noise (noise-power spectrum, NPS), noise-equivalent quanta (NEQ), and task-based …

    toronto-retro Repository record for Task-based Imaging Performance in 3D X-Ray Tomography: Noise, Detectability, and Implications for System Design (opens in a new tab)

  19. Attenuation, noise, and image quality in single-photon emission computed tomography

    … attenuating medium, the attenuation problem is modelled by the exponential Radon transform. In this dissertation, we mathematically describe the three, previously published, analytical inverses to this forward problem, known as the methods of Bellini, Inouye, and Tretiak & Metz. Also included …

    arizona-thes Repository record for Attenuation, noise, and image quality in single-photon emission computed tomography (opens in a new tab)

  20. Utilisation des modèles observateurs pour l'optimisation de la qualité image basée sur la prédiction du maximum de détectabilité

    La constante évolution des outils de gestion de la dose en imagerie scanner, en particulier avec l'avènement de nouveaux algorithmes de reconstruction, a complexifié la démarche d'optimisation des protocoles, imposant le besoin d'une gestion automatisée. Pour ce faire, le recours aux modèles …

    star-france Repository record for Utilisation des modèles observateurs pour l'optimisation de la qualité image basée sur la prédiction du maximum de détectabilité (opens in a new tab)

Page 1 of 2