Showing 1 to 20 of 20 for “"Model-based iterative reconstruction"”.
-
CT dose optimization with model based iterative reconstruction
… thesis is to assess the feasibility of using model-based iterative reconstruction (MBIR) to develop new low-dose CT (computed tomography) protocols in the areas of neck, chest, and abdominal imaging without compromising diagnostic performance. Medical imaging has become the largest source of …
-
High-quality computed tomography using advanced model-based iterative reconstruction
… structures beyond current system capabilities. Model-Based Iterative Reconstruction (MBIR) techniques offer improved image quality over traditional methods by incorporating more accurate models of the imaging physics. In this work, we seek to improve image quality by including high-fidelity …
-
A Model Based Iterative Reconstruction Approach to Tunable Diode Laser Absorption Tomography
… problem. In this thesis, we study the problem of reconstruction of TDLAT measurements into images representing 2D flow fields. We first propose a novel model-based iterative reconstruction (MBIR) framework for TDLAT imaging. To do this, we formulate a nonlinear measurement model for TDLAT that …
-
Model-Based Iterative Reconstruction in Cone-Beam Computed Tomography: Advanced Models of Imaging Physics and Prior Information
… CBCT), and surgical guidance (e.g., C-arm based CBCT). However, the current generation of CBCT systems face major challenges in low-contrast, soft-tissue image quality – for example, in the detection of acute intracranial hemorrhage (ICH), which requires a fairly high level of image …
-
Advanced Statistical Modeling for Model-Based Iterative Reconstruction for Single-Energy and Dual-Energy X-Ray CT
Model-based iterative reconstruction (MBIR) has been increasingly broadly applied as an improvement over traditional, analytical image reconstruction methods in X-ray CT, primarily due to its significant advantage in drastic dose reduction without diagnostic loss. Early success of the method in …
-
Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging
… and bias. Here we test the possibility of using model based iterative reconstruction algorithms (MBIRs) for generating the sparse-view, ultra-low-dose (i.e. an order lower than current low-dose protocols) CTAC images for both phantom and patient PET data. We also propose a new variance estimation …
-
The non-drug management of patients with chronic gastrointestinal disease
… a low radiation dose CT protocol using model based iterative reconstruction, to reduce effects of radiation exposure associated with high BMI, to be an effective first-line imaging modality without image compromise. To mitigate effects of medication sideeffects using non-drug therapies, …
-
PREDICTION AND CONTROL OF IMAGE PROPERTIES IN ADVANCED COMPUTED TOMOGRAPHY
… a prospective prediction framework for advanced reconstruction in CBCT and spectral CT systems. These predictors analyze the dependencies of image properties on system configuration, acquisition strategy, and reconstruction regularization design. The prospective estimation of image properties …
-
Image Reconstruction for X-ray Computed Tomography in Security Screening Applications
… present a new set of challenges for the reconstruction problem. For example, the size and composition of the scan subjects, the throughput requirements, and the measure of image quality are all factors that lead to a different set of design considerations. This thesis investigates the …
-
Using electrons to fabricate and characterise three-dimensional ferromagnetic nanostructures
… and a method is developed for tomographic reconstruction of magnetisation in 3D. The tomographic method, based on model-based iterative reconstruction (MBIR), incorporates tomographic alignment and image-distortion correction algorithms, enabling experimental reconstruction of a 3D …
-
Optimierte modellbasierte Rekonstruktionsverfahren der computertomographischen Bildgebung zur besseren Darstellung von Leberläsionen
… Metastasen. Zu diesen neuartigen Methoden zählen modellbasierte iterative Rekonstruktionsverfahren. In dieser Studie wurde die Auswirkung auf die Bildqualität durch ein solches Verfahren, Forward Projected Model-Based Iterative Reconstruction SoluTion Low Contrast Detectability (FIRST) Low …
-
Iterative reconstruction as a novel method of radiation dose reduction at computed tomography in patients with Crohn's disease
… limitation with conventional CT raw data reconstruction was the inherent coupling of administered radiation dose with observed image noise – the lower the radiation dose, the noisier the image. The renaissance, rediscovery and refinement of iterative reconstruction removes this limitation …
-
IMPROVED IMAGE QUALITY IN CONE-BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED INTERVENTIONS
… that provides single rotation 3D volumetric reconstruction with sub-millimeter spatial resolution. Compared to the conventional multi-detector CT (MDCT), CBCT exhibited a number of characteristics that are well suited to applications in image-guided interventions, including improved …
-
High-Resolution Quantitative Cone-Beam Computed Tomography: Systems, Modeling, and Analysis for Improved Musculoskeletal Imaging
This dissertation applies accurate models of imaging physics, new high-resolution imaging hardware, and novel image analysis techniques to benefit quantitative applications of x-ray CT in in vivo assessment of bone health. We pursue three Aims: 1. Characterization of macroscopic joint space …
-
Alfvén waves underlying ionospheric destabilization: ground-based observations
… tomographic auroral observatories using model based iterative reconstruction (MBIR) techniques were developed in this dissertation. The TRANSCAR electron penetration model creates a basis set of monoenergetic electron beam eigenprofiles of auroral volume emission rate for the given …
-
Image Reconstruction for Hyperpolarized Carbon-13 Metabolic Magnetic Resonance Imaging with Iterative Methods
… and post-treatment response in both animal models and clinical trials. This dissertation focuses on the application of novel iterative image reconstruction methods for 13C MRI that aim to improve image quality and temporal resolution.One of the challenges for the existing 13C MRI …
-
Improving cone-beam CT image quality using non-circular orbits
… and develops the acquisition, calibration, reconstruction, and analysis tools needed to support that claim. The dissertation makes three contributions. First, an acquisition workflow and a fully automatic online geometric calibration algorithm enable arbitrary non-circular orbits on clinical …
-
Advanced Techniques for Image Quality Assessment of Modern X-ray Computed Tomography Systems
… control (i.e., tube current modulation) and iterative reconstruction algorithms. In theory, these technologies could allow for scanning at reduced doses while maintaining the image quality of the exam at an acceptable level. Therefore, there is a scientific need to establish the dose …