  1. Moisture Buffering Capacity of Unfired Clay Masonry

    … to bring attention to this phenomenon called moisture buffering where the building envelope plays a major role in the moisture balance of the building. Yet only a limited amount of research has been done on one of the most promising materials in terms of moisture buffering …

    bath Repository record for Moisture Buffering Capacity of Unfired Clay Masonry (opens in a new tab)

  2. Transient moisture characteristics of spruce plywood

    In this thesis, the moisture characteristics of spruce plywood are studied experimentally and numerically with special attention given to moisture storage and release as the indoor humidity changes diurnally. This is referred to as the moisture buffering capacity. Two test facilities (a glass jar …

    sask Repository record for Transient moisture characteristics of spruce plywood (opens in a new tab)

  3. Investigation on moisture buffering of hygroscopic materials by full-scale experiments and HAM simulations

    The moisture buffering effect of interior hygroscopic materials can reduce the variation of indoor RH, thus to achieve a desired indoor environment and to obtain a better building envelope performance while saving energy consumed in operating HVAC equipment. Even though a large number of studies …

    concordia

  4. Experimental investigation of the hygrothermal performance of single and multi-layer wall systems in the context of Iran’s construction techniques

    … study considering simultaneous heat and moisture transfer and interactions of adjacent layers in a multi-layer system. In a mutual order, the motive to abide by sustainability criteria in building design has resulted in an increased interest in use of natural materials increasing the need …

    bath Repository record for Experimental investigation of the hygrothermal performance of single and multi-layer wall systems in the context of Iran’s construction techniques (opens in a new tab)

  5. EARTH & FIBERS. Local Technologies Earthen Composites (LoTEC) : local reuse of by-products for zero-waste building materials, appropriate building solutions in vernacular and contemporary architecture

    … into the environment. Their permeability and moisture-buffering capacity make them particularly compatible with the vapor-open nature of historical materials, enabling effective retrofitting and improved indoor comfort while preserving architectural heritage. They also perform efficiently in …

    barcelona Repository record for EARTH & FIBERS. Local Technologies Earthen Composites (LoTEC) : local reuse of by-products for zero-waste building materials, appropriate building solutions in vernacular and contemporary architecture (opens in a new tab) Embargoed

  6. EARTH & FIBERS. Local Technologies Earthen Composites (LoTEC). Local reuse of by-products for zero-waste building materials. Appropriate building solutions in vernacular and contemporary architecture.

    … into the environment. Their permeability and moisture-buffering capacity make them particularly compatible with the vapor-open nature of historical materials, enabling effective retrofitting and improved indoor comfort while preserving architectural heritage. They also perform efficiently in …

    cagliari Repository record for EARTH & FIBERS. Local Technologies Earthen Composites (LoTEC). Local reuse of by-products for zero-waste building materials. Appropriate building solutions in vernacular and contemporary architecture. (opens in a new tab) Embargoed

  7. Earth stabilisation by plant-derived urease enzyme for building applications

    … adsorption/desorption was assessed by measuring moisture buffering value (MBV). Durability to water erosion was also evaluated by performing suction, immersion and drip tests according to the norms DIN 18945 (2013) and NZS 4298 (1998), respectively. Results showed that hyper-compaction largely …

    durham Repository record for Earth stabilisation by plant-derived urease enzyme for building applications (opens in a new tab)

  8. Understanding moisture buffering effects in the indoor environment

    … on exposed surfaces to the room air. Their capacity to moderate indoor humidity fluctuations is due to their ability to adsorb and desorb moisture, a process referred to as moisture buffering. This property is evaluated through the MBV, which allows for a simplistic calculation of the …

    bath Repository record for Understanding moisture buffering effects in the indoor environment (opens in a new tab)

  9. Improved energy recovery from municipal solid wastes in sanitary landfills by two-phase digestion of biomass.

    … of MSW. Sewage sludge was utilized to provide moisture, buffering capacity, nutrients, and an adequate microbial population. Single-phase systems with other enhancement techniques were also compared to the two-phase with sludge addition. Data from this study indicated that gas produced in the …

    wvu Repository record for Improved energy recovery from municipal solid wastes in sanitary landfills by two-phase digestion of biomass. (opens in a new tab)

  10. Optimisation des performances hygrothermiques de parois en bétons biosourcés : approche expérimentale et numérique

    Ces dernières décennies, les fortes préoccupations environnementales visant à lutter contre le réchauffement climatique ont mis en avant liimpact du secteur de l'’énergie, et particulièrement celui des bâtiments. La communauté scientifique s'est alors intéressée au potentiel que représente …

    star-france Repository record for Optimisation des performances hygrothermiques de parois en bétons biosourcés : approche expérimentale et numérique (opens in a new tab)

  11. Étude du comportement hygro- mécanique de la terre crue hyper-compactée pour la construction durable

    … été analysé par la mesure du paramètre MBV (i.e. Moisture Buffering Value), qui traduit la capacité d’échange avec la vapeur d’eau. Il s'avère que la terre non stabilisée possède une excellente capacité à absorber et relarguer l’humidité ambiante. Cette capacité est, par contre, réduite pour les …

    star-france Repository record for Étude du comportement hygro- mécanique de la terre crue hyper-compactée pour la construction durable (opens in a new tab)