Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 32 for “"Moment Connection"”.

  1. Developing and Validating New Bolted End-Plate Moment Connection Configurations

    This research has been aimed to introduce larger moment carrying connections for any type of buildings, in particular the metal building industry. A total of four connection configurations, namely eight-bolt extended four wide, eight-bolt extended stiffened, six bolt flush unstiffened and twelve …

    vt Repository record for Developing and Validating New Bolted End-Plate Moment Connection Configurations (opens in a new tab)

  2. Development and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connection

    Three end-plate moment connection configurations are prequalified for special moment frames for seismic applications in AISC 358-10. The eight bolt extended stiffened connection is the strongest of the three configurations, but it can only develop approximately 30 percent of currently available …

    vt Repository record for Development and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connection (opens in a new tab)

  3. Evaluating the Non-Linear Behaviour of a Timber-Steel Moment Resisting Connections

    Timber moment resisting connections have gained considerable interest in structural design due to the numerous advantages offered by timber as a lightweight, renewable, sustainable, and aesthetically pleasing material. This research focuses on investigating the feasibility and potential benefits of …

    ottawa-retro Repository record for Evaluating the Non-Linear Behaviour of a Timber-Steel Moment Resisting Connections (opens in a new tab)

  4. Unified Design of Extended End-Plate Moment Connections Subject to Cyclic Loading

    … design procedures for eight extended end-plate moment connection configurations subject to cyclic/seismic loading. In addition, the suitability of extended end-plate moment connections for use in seismic force resisting moment frames was investigated. Eleven full-scale cyclic and nine monotonic …

    vt Repository record for Unified Design of Extended End-Plate Moment Connections Subject to Cyclic Loading (opens in a new tab)

  5. Evaluating the Effect of Decking Fasteners on the Seismic Behavior of Steel Moment Frame Plastic Hinge Regions

    A series of full-scale beam-to-column moment connection tests were completed to determine the effects of powder actuated fasteners (PAF) and puddle welds on the seismic behavior of steel moment connections. In seismic regions, PAF are currently prohibited in the connection region (referred to as …

    vt Repository record for Evaluating the Effect of Decking Fasteners on the Seismic Behavior of Steel Moment Frame Plastic Hinge Regions (opens in a new tab)

  6. Evaluation of Extended End-Plate Moment Connections Under Seismic Loading

    … was conducted to study the extended end-plate moment connections subjected to cyclic loading. Seven specimens representing three end-plate moment connection configurations commonly used in the pre-engineered building industry were used. The connections were designed using yield-line theory to …

    vt Repository record for Evaluation of Extended End-Plate Moment Connections Under Seismic Loading (opens in a new tab)

  7. Seismic performance of an I-girder to inverted-T bent cap bridge connection

    … regarding the seismic response and overall moment capacity of precast I-girder to inverted-T bent cap bridge connections for seismic applications. The current design practice, as outlined by Caltrans' Seismic Design Criteria, assumes that the connection between the precast I-girders and the …

    iastate Repository record for Seismic performance of an I-girder to inverted-T bent cap bridge connection (opens in a new tab)

  8. Behaviour of Blind Bolted Moment Connections for Square HSS Columns

    … their use as columns in low or medium-rise moment-resisting steel frames has been limited. Some of the difficulties are due to the lack of a simple and practical field-bolted moment connection between a W-shape beam and an HSS column.</p> <p>The objectives of this research study are to …

    mcmaster Repository record for Behaviour of Blind Bolted Moment Connections for Square HSS Columns (opens in a new tab)

  9. Moment-Rotation Behavior of Extended End-Plate Connections Under Cyclic Loading, Phase Two Emphasizing Column-Side Response

    … beam/column sub-assemblages to investigate the moment-rotation characteristics of various moment-resisting connection configurations. Specifically, the column-side response of the extended end-plate moment connection was investigated in an effort to gain better understanding of the column limit …

    ku Repository record for Moment-Rotation Behavior of Extended End-Plate Connections Under Cyclic Loading, Phase Two Emphasizing Column-Side Response (opens in a new tab)

  10. Πειραματική και αναλυτική διερεύνηση της συμπεριφοράς κοχλιωτών συνδέσεων RBS υπό εναλλασόμενη φόρτιση

    Widespread damage to steel moment frame structures during the 1994 Northridge and 1995 Cobe earthquakes led researchers to develop alternative connection designs to the prescriptive pre-Northridge moment connection. Two key concepts have been developed to provide highly ductile response and …

    greece Repository record for Πειραματική και αναλυτική διερεύνηση της συμπεριφοράς κοχλιωτών συνδέσεων RBS υπό εναλλασόμενη φόρτιση (opens in a new tab)

  11. Evaluation of Experimental Bridges in Tennessee

    … spans. TDOT has developed the Pier-Plate Moment Connection in order to facilitate the accelerated construction of steel girder bridges. This connection allows the girders of a multispan steel bridge to be erected as simple spans and then to be made continuous prior to the dead load of the …

    utk-theses Repository record for Evaluation of Experimental Bridges in Tennessee (opens in a new tab)

  12. Experimental and Analytical Investigation of the Shear Strength of Unstiffened Tapered Steel Members

    … to bending in similar proportion to the bending moments, more economical structures can be obtained. The beam and column connection, or knee area, is generally subject to the greatest bending moments. It is therefore comprised of the deepest sections of the tapered members, which also possess the …

    vt Repository record for Experimental and Analytical Investigation of the Shear Strength of Unstiffened Tapered Steel Members (opens in a new tab)

  13. BEHAVIOUR OF BOX-COLUMN TO I-BEAM CONNECTIONS

    … the fabrication and erection of beam-to-column connections which is inherent in every building. Due to the repetitive nature of these connections, even a minor material or labour saving in one connection is compounded throughout the entire building, giving rise to substantial cost savings. The …

    nus Repository record for BEHAVIOUR OF BOX-COLUMN TO I-BEAM CONNECTIONS (opens in a new tab) Download file for BEHAVIOUR OF BOX-COLUMN TO I-BEAM CONNECTIONS (opens in a new tab)

  14. Innovative Self-Centering Connection for CCFT Composite Columns

    … filled steel tubes. However, most common connection configurations for circular concrete filled tubes are not economic in the US market due to (a) the desire of designers to use only fully restrained connections and its associated (b) high cost of fabrication and field welding. Research …

    vt Repository record for Innovative Self-Centering Connection for CCFT Composite Columns (opens in a new tab)

  15. Timber moment connections using glued-in steel rods

    … in this thesis focused on timber-steel hybrid moment connections using d=12.7mm diameter mild steel threaded rods glued into Douglas-Fir glulam with polyurethane based adhesive. Two phases of experiments were conducted: the first to determine the minimum design parameter values that result in a …

    ubc Repository record for Timber moment connections using glued-in steel rods (opens in a new tab) Download PDF for Timber moment connections using glued-in steel rods (opens in a new tab)

  16. Evaluation, Comparison, and Design of Two Experimental Bridges in Tennessee

    … the design and evaluates the adequacy of the moment connection of an experimental two-span highway bridge designed by the Tennessee Department of Transportation. The Massman Drive bridge is an experimental design that unifies the construction economy of simple span bridges and the structural …

    ut-knoxville Repository record for Evaluation, Comparison, and Design of Two Experimental Bridges in Tennessee (opens in a new tab)

  17. Developing Extended Strands in Girder-Diaphragm Connections for Positive Moment Resistance

    … and compression, respectively. The tension connection is presently made by extending some of the bottom strands into the cast-in-place diaphragm. At this location, the space available is too small for development by bond in the straight strands alone. Since concrete in the diaphragm is …

    washington Repository record for Developing Extended Strands in Girder-Diaphragm Connections for Positive Moment Resistance (opens in a new tab)

  18. Application of Ductile Yield Link in Glulam Moment Connections

    Wood beam-column connections have traditionally been designed as simple shear connections, ignoring their potential moment capacity. A major reason for not utilizing such moment connections is linked to the brittle limit states that wood components exhibit. The purpose of this research was to …

    vt Repository record for Application of Ductile Yield Link in Glulam Moment Connections (opens in a new tab)

  19. Tension bolt behavior in moment connections for seismic applications

    … doubts about the performance of the welded moment connection, until now the most popular and reliable steel beam-column connection. A careful study of the structures damaged by these earthquakes, has established that welded connections mainly failed due to fracture along the full penetration …

    texas Repository record for Tension bolt behavior in moment connections for seismic applications (opens in a new tab) Restricted access

Page 1 of 2