Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"Moment Connections"”.
-
Expedient moment connections for timber portal frame buildings
This thesis introduces an expedient semi-rigid moment connection, the Quick Connect, for use in timber portal frames. The connection is rod based, with components which have easily determinable attributes. Connection components are sized by means of a simple design methodology which has been …
-
Timber moment connections using glued-in steel rods
… in this thesis focused on timber-steel hybrid moment connections using d=12.7mm diameter mild steel threaded rods glued into Douglas-Fir glulam with polyurethane based adhesive. Two phases of experiments were conducted: the first to determine the minimum design parameter values that result in a …
-
Experimental Evaluation of Replaceable Shear Fuse Moment Connections
Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …
-
Tension bolt behavior in moment connections for seismic applications
… doubts about the performance of the welded moment connection, until now the most popular and reliable steel beam-column connection. A careful study of the structures damaged by these earthquakes, has established that welded connections mainly failed due to fracture along the full penetration …
-
Application of Ductile Yield Link in Glulam Moment Connections
Wood beam-column connections have traditionally been designed as simple shear connections, ignoring their potential moment capacity. A major reason for not utilizing such moment connections is linked to the brittle limit states that wood components exhibit. The purpose of this research was to …
-
Evaluation of Extended End-Plate Moment Connections Under Seismic Loading
… was conducted to study the extended end-plate moment connections subjected to cyclic loading. Seven specimens representing three end-plate moment connection configurations commonly used in the pre-engineered building industry were used. The connections were designed using yield-line theory to …
-
Behaviour of Blind Bolted Moment Connections for Square HSS Columns
… their use as columns in low or medium-rise moment-resisting steel frames has been limited. Some of the difficulties are due to the lack of a simple and practical field-bolted moment connection between a W-shape beam and an HSS column.</p> <p>The objectives of this research study are to …
-
Moment Connections for Vierendeel Trusses of Square Hollow Structural Sections
… of Vierendeel trusses comprised of semi-rigid connections under panel feint loadings. The semi-rigid connections are made of two unequal width square ESS members welded at right angles. As the flexibility of the joints increases when the width ratio is less than 1.0, the joints are unable to …
-
Evaluating the Fracture Potential of Steel Moment Connections with Defects and Repairs
Steel moment frames are a popular seismic-force resisting system, but it is believed that they are susceptible to early fracture if there is a stress concentration in the plastic hinge region, also known as the protected zone. If a defect is present in this area, it may be repaired by grinding …
-
Unified Design of Extended End-Plate Moment Connections Subject to Cyclic Loading
… design procedures for eight extended end-plate moment connection configurations subject to cyclic/seismic loading. In addition, the suitability of extended end-plate moment connections for use in seismic force resisting moment frames was investigated. Eleven full-scale cyclic and nine monotonic …
-
Evaluation of the Inelastic Rotation Capability of Flush End-Plate Moment Connections
… inelastic rotation capability of flush end-plate moment connections. Seven specimens representing two-bolt and four-bolt flush end-plate configurations were tested under cyclic loading. "Quasi-static" or "slow-cyclic" loading histories suggested by SAC and the Applied Technology Council were used …
-
An Experimental Investigation of Unequal Width HSS Moment Connections for Vierendeel Trusses
… The specimens tested were all unequal width connections and two distinct b/h values were used (0.60 and 0.83). Four specimens were unreinforced while the remaining ten had three distinct reinforcement types. These were branch member flange stiffening plates, chord member top flange stiffeners …
-
Moment Connections of Concrete-Filled Fibre Reinforced Polymer Tubes to Reinforced Concrete Footings
… very little attention has been given to their connections to other structural components such as footings and beams. This study explores two different moment connections for CFFT members, using 13 medium-scale specimens and seven ancillary tests. The first connection involves embedment of the …
-
Effect of fire and fire following an earthquake on steel reduced beam section moment connections
… The subassemblies are representative of actual connections in two steel special moment resisting frames that were designed for the highly seismic Los Angeles region. The frames selected for analysis are an 8-story 4-bay frame and a 16-story 4-bay frame and the selected subassemblies are located …
-
Response of Cyclically Loaded Extended End-Plate Moment Connections When Used With Welded Built-Up Sections
… to study the behavior of extended end-plate moment connections subjected to cyclic loading. Eleven specimens were tested, representing typical connection configurations used in the metal building manufacturing industry. Four of the beams were shallow (30 in. or less), and seven were deep (60 …
-
Flexural Performance and Moment Connections of Concrete-Filled GFRP Tubes (CFFTs) and CFFT-encased Steel I-Sections
… Phase II addresses the development of a moment connection through cantilever tests. The connection consists of steel base plates welded to the steel sections, which are embedded into CFFT members at various length-to-span (Ls/L) ratios between 0.1 and 1.0. Three distinct failure modes are …
-
Experimental Design for Determining the Cyclic Behavior of Skewed Reduced Beam Section Moment Connections having Composite Slabs
… behavior of skewed Reduced Beam Section (RBS) moment connections having composite slabs. The effects of composite concrete slabs on skewed RBS connections subjected to cyclic seismic prequalification loading are addressed in this test setup. Full-scale double-sided RBS SMF specimens …