Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 107 for “"Moment Frame"”.

  1. Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design

    … fluid dampers on a nine story special steel moment frame designed for strength in Seattle. At the initial stages of the work, knowing the fact that moment frames are almost always controlled by drift, it was thought that two different moment frames, controlled by strength or controlled by …

    vt Repository record for Effect of Viscous Fluid Dampers on Steel Moment Frame Designed for Strength and Hybrid Steel Moment Frame Design (opens in a new tab)

  2. OPTIMIZATION OF STEEL MOMENT FRAME USING HARMONY SEARCH ALGORITHM

    … HS algorithm obtained lighter weight of steel frames by selecting a suitable steel section from the American Institute of Steel Construction (AISC) and by following the specification of Allowable Stress Design method (ASD). The results show that HS yielded lighter steel moment frames with …

    temple Repository record for OPTIMIZATION OF STEEL MOMENT FRAME USING HARMONY SEARCH ALGORITHM (opens in a new tab)

  3. Redundancy in Steel Moment Frame Systems Under Seismic Excitations

    Finally, a framework is proposed for evaluation of structural redundancy against incipient collapse limit state. In this framework: (1) the maximum column drift ratio (MCDR) or biaxial spectral acceleration (BSA) is used to measure both demand and capacity of a given building; (2) the demand and …

    uiuc Repository record for Redundancy in Steel Moment Frame Systems Under Seismic Excitations (opens in a new tab)

  4. Peak Connection Strength of Reduced Beam Section Moment Frame Connections

    In the design of reduced beam section (RBS) moment frame connections, the peak connection strength factor (𝐶𝑝𝑟) is used to estimate the expected maximum moment at the reduced section in the capacity-based design of moment-resisting frames. Current design provisions in AISC 358-22 define C𝑝𝑟 as the …

    byu Repository record for Peak Connection Strength of Reduced Beam Section Moment Frame Connections (opens in a new tab) Download PDF for Peak Connection Strength of Reduced Beam Section Moment Frame Connections (opens in a new tab)

  5. Lateral-Torsional Buckling Capacity of Tapered-Flange Moment Frame Shapes

    While moment frames are a popular lateral-force resisting system, their constant cross-section can lead to inefficiencies in energy absorption and stiffness. By tapering the flange width linearly toward the center of the beam length, the energy absorption efficiency can be increased, leading to a …

    byu Repository record for Lateral-Torsional Buckling Capacity of Tapered-Flange Moment Frame Shapes (opens in a new tab) Download PDF for Lateral-Torsional Buckling Capacity of Tapered-Flange Moment Frame Shapes (opens in a new tab)

  6. Low-damage gravity rocking connection for multi-storey moment frame buildings

    … avoidance solution for timber or hybrid timber moment resisting frames (MRFs). Full system damage avoidance selfcentring behaviour is difficult to achieve with existing systems due to damage to the floor slab caused by beam-elongation. A novel gravity rocking, self-centring beam-column joint …

    auckland-ms Repository record for Low-damage gravity rocking connection for multi-storey moment frame buildings (opens in a new tab)

  7. Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification

    Special moment frames having specially detailed connections are common in high seismic regions, providing architectural flexibility for passageways and views without brace obstructions. In situations where the building framing layout requires deviation from typical rectangular framing, skew in the …

    arkansas Repository record for Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification (opens in a new tab)

  8. Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates

    … and evaluation of a new special steel moment frame connection that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 …

    byu Repository record for Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates (opens in a new tab) Download PDF for Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates (opens in a new tab)

  9. Structural Redundancy of Dual and Steel Moment Frame Systems Under Seismic Excitation

    The proposed uniform-risk redundancy factor is then compared with the reliability and redundancy factor (rho) in the 1996 SEAOC Blue Book, NEHRP 97, and UBC 97, which depends on the system configuration only. The results show the inadequacies of the latter approach in describing the redundancy of a …

    uiuc Repository record for Structural Redundancy of Dual and Steel Moment Frame Systems Under Seismic Excitation (opens in a new tab)

  10. Full-scale seismic testing of a reinforced concrete moment frame using mobile shakers

    A prototype reinforced concrete moment frame representative of low-rise office buildings in the Central and Eastern United States from the 1950s-1970s was designed and selected for evaluation under seismic loads. A plane frame specimen from the prototype was incorporated into the design of a …

    gatech Repository record for Full-scale seismic testing of a reinforced concrete moment frame using mobile shakers (opens in a new tab)

  11. On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections

    Special Moment Frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs, as they provide lateral system stiffness without the use of braces which often obstruct views and architectural features. Reduced beam section (RBS) connections are popular SMF connection …

    arkansas Repository record for On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections (opens in a new tab)

  12. Development of Multiobjective Optimization Procedures for Seismic Design of Steel Moment Frame Structures

    … of code-compliant regular plane steel special moment resisting frame structures with simultaneous as well as separate treatment of multiple objective functions that reflect steel material usage, initial expenses, degree of design complexity, seismic structural performance indices, and lifetime …

    uiuc Repository record for Development of Multiobjective Optimization Procedures for Seismic Design of Steel Moment Frame Structures (opens in a new tab)

  13. Experimental and Computational Investigation of a Self-Centering Beam Moment Frame (SCB-MF)

    … with the gravity framing. A self-centering beam moment frame (SCB-MF) has been developed that virtually eliminates residual drifts and concentrates the majority of structural damage in replaceable fuse elements. The SCB consists of a I-shaped steel beam augmented with a restoring force mechanism …

    vt Repository record for Experimental and Computational Investigation of a Self-Centering Beam Moment Frame (SCB-MF) (opens in a new tab)

  14. Finite element analysis of steel moment frame joints with doubler plates and continuity plates

    … in beam-column joints in seismic resistant steel moment frames, with a focus on the interaction between continuity plates and extended doubler plates. Several recent studies have examined this same issue, but utilized a simplified finite element model of the panel zone region that did not include …

    texas Repository record for Finite element analysis of steel moment frame joints with doubler plates and continuity plates (opens in a new tab)

  15. Probabilistic Seismic Damage Assessment And Repair Cost Analysis Of Existing Steel Moment Frame Buildings

    … and failure. An existing eight-story steel moment frame building located in Los Angeles, California is chosen as a case study to illustrate the application of the stochastic methods. To evaluate the seismic reliability of the building, a large number of ground motions are generated that …

    cornell Repository record for Probabilistic Seismic Damage Assessment And Repair Cost Analysis Of Existing Steel Moment Frame Buildings (opens in a new tab)

  16. Computational Fracture Prediction in Steel Moment Frame Structures with the Application of Artificial Neural Networks

    Damage to steel moment frames in the 1994 Northridge and 1995 Hyogken-Nanbu earthquakes subsequently motivated intensive research and testing efforts in the US, Japan, and elsewhere on moment frames. Despite extensive past research efforts, one important problem remains unresolved: the degree of …

    tamu Repository record for Computational Fracture Prediction in Steel Moment Frame Structures with the Application of Artificial Neural Networks (opens in a new tab)

  17. Ductile Design and Predicted Inelastic Response of Steel Moment Frame Buildings for Extreme Wind Loads

    … A three-story office building that uses steel moment frames as the primary lateral force resisting system was examined to test the hypothesis. Various levels of ductility were included based on ductility requirements for material strength, section stability and system stability originally …

    byu Repository record for Ductile Design and Predicted Inelastic Response of Steel Moment Frame Buildings for Extreme Wind Loads (opens in a new tab) Download PDF for Ductile Design and Predicted Inelastic Response of Steel Moment Frame Buildings for Extreme Wind Loads (opens in a new tab)

  18. Cyclic Testing of a Skewed Special Moment Frame RBS Connection Having a Composite Concrete Slab

    Special moment frames (SMFs) having reduced beam section (RBS) connections are commonly used in high seismic areas as they resist lateral forces while preserving critical welded connection regions. RBS SMFs provide brace-free, unobstructed frame options which can be favorable for architectural …

    arkansas Repository record for Cyclic Testing of a Skewed Special Moment Frame RBS Connection Having a Composite Concrete Slab (opens in a new tab)

  19. Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses

    Special moment frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs. SMFs provide lateral system stiffness without the use of braces that often obstruct views and architectural features. Current American Institute of Steel Construction (ASIC) provisions …

    arkansas Repository record for Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses (opens in a new tab)

Page 1 of 6