Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 158 for “"Moment Resisting Frames"”
-
Seismic performance evaluation of reinforced concrete moment resisting frames
… method is still allowed. In this study, three moment resisting frame buildings assumed to be located in Vancouver, British Columbia are designed based on the equivalent static load method of the NBCC 2005 and their performance is evaluated using nonlinear dynamic time-history analysis. Multiple …
-
Inelastic panel zone deformation demands in stell moment resisting frames
Panel zone is one of the significant parts of beam-column connections in steel structures. Until the 1994 Northridge Earthquake, a few experimental research and parametric studies had been carried out to understand the behavior of the panel zones. However, after the Northridge Earthquake, it was …
-
Seismic Response of Moment Resisting Frames Coupled with Rocking Walls
… is of major significance in the design of tall moment-resisting buildings, since during recent major earthquakes several tall, moment-resisting frames that had been designed in an accordance to the existing seismic code provisions, exhibited a weak-story failure. Utilization of this structural …
-
Advances in structural robustness of reinforced concrete moment resisting frames
L'abstract è presente nell'allegato / the abstract is in the attachment
-
Three-dimensional non-linear analyses of steel special moment resisting frames
A special moment resisting frame (SMRF) is a type of lateral force resisting system that is used to protect structures from extreme seismic events. This report evaluates the performance of a steel SMRF with an emphasis on the lower story elements. Previous research evaluating the performance of a …
-
The elongation of beams in reinforced concrete special moment resisting frames
Special moment resisting frames (SMRF) are intended to protect the structure from earthquake motions through a ductile inelastic response. This thesis evaluates the performance of reinforced concrete SMRFs with an emphasis on the second level beams. Due to previous research, it is concluded that …
-
Seismic design and evaluation of moment resisting frames using elastomeric dampers
… <p>The seismic performance of a 10 storey steel moment resisting frame was evaluated, and the eect of the dampers on the frame's performance was examined. The dampers were designed to provide an additional 10% damping to the Eurocode 8 compliant building. The structure was tested with and without …
-
Parametric collapse evaluation of steel moment resisting frames with fuse connections
… a low damage seismic design concept for steel moment resisting frames (MRFs): the moment resisting fuse connection. Fuse connections are moment resisting connections that yield prior to the beam or column they connect. The connection acts as an easily repairable structural fuse of the seismic …
-
Seismic design procedure for steel moment resisting frames with viscous dampers
… of elastic or mildly inelastic structures.Steel moment-resisting frames (MRFs) with viscous dampers are prone to plastic mechanisms that involve hinges in columns because of the large column axial forces due to the large damper forces and have less collapse resistance than conventional steel MRFs …
-
Extended end-plate beam-column joints in seismic moment resisting frames
<p>Although moment resisting frames (MRFs) are the most widely used structural system for seismic-resistant steel buildings, several important aspects of their behaviour under real earthquake excitation are not well understood. One of these issues that needs to be further studied is the seismic …
-
Inelastic Analysis of Steel Moment Resisting Frames in Light-Framed Wood Buildings
A preliminary quantitative analysis of steel moment resisting frames as the lateral force-resisting system for light-framed wood buildings was completed to identify issues requiring more advanced study. A two-story prototype building was evaluated. The lateral force-resisting system of the building …
-
Preliminary analysis of doubler plate attachment details for steel moment resisting frames
In steel moment resisting frames, the region of the column located within the beam-column joint is known as the panel zone. When a steel moment resisting frame is subjected to lateral load, due to wind or seismic loads, the panel zone is subject to high shear. In some cases, the shear in the panel …
-
Response modification factor of reinforced concrete moment resisting frames in developing countries
… the R factor of reinforced concrete (RC) moment resisting frames (MRFs) in Pakistan. A suite of ground motion records from the region is used in the study. Two-dimensional building models are developed in OpenSees and subjected to nonlinear time history analysis. Fiber sections with …
-
Behavior Of Thick Flange Built-up T-stub Connections For Moment Resisting Frames
… which meet the prequalification requirements for moment-resisting-frames (MRF). Oftentimes the heavy rolled profiles needed to fabricate the T-stub for such deep beams are not immediately available to fabricators and so built-up sections are the only alternative. In this study, finite element (FE) …
-
Prequalification and Design of Rolled Bolted T-stub Connections in Moment Resisting Frames
Implementation of moment frames as the primary Seismic Lateral Resisting System (SLRS) has become increasingly popular over the years due to their ability to create open layouts and long, uninterrupted spans. Welded connections were typically used to create the fully-restrained (FR) beam-to-column …
-
Evaluation of the effects of insertion of viscous dampers in Moment Resisting Frames
… the problem of insertion of viscous dampers into Moment Resisiting Frames (MRF) for maximum efficiency in mitigation of the seismic effects. The work would lead to a precise design indication. The fundamental result of the thesis consists in showing that, even for moment-resisting structures, you …
-
Cyclic loading analysis of doubler plate attachment details for steel moment resisting frames
… region in columns of seismic resistant steel moment frames are subject to very high shear forces during earthquake loading. Doubler plates are often used to increase the stiffness and strength of the panel zone. The methods and details used to attach doubler plates to columns can affect …
-
Seismic Retrofitting of Conventional Reinforced Concrete Moment-Resisting Frames Using Buckling Restrained Braces
… tests of large-scales reinforced concrete frames under slowly applied lateral deformation reversals, and the analytical research involved design and nonlinear analysis of laboratory specimens, as well as design and dynamic inelastic response history analysis of selected prototype buildings …
-
Effects of Strain Rate Dependency on Moment Resisting Frames with Reduced Beam Sections
… conducted to investigate the performance of a moment frame with reduced beam section (RBS). However, most of the numerical studies have not been carried out using realistic material properties and constitutive model that can more accurately represent the material response. Strain rate dependent …
Page 1 of 8