Timber moment connections using glued-in steel rods
… in this thesis focused on timber-steel hybrid moment connections using d=12.7mm diameter mild steel threaded rods glued into Douglas-Fir glulam with polyurethane based adhesive. Two phases of experiments were conducted: the first to determine the minimum design parameter values that result in a …
-
Evaluation of Beam-to-Column Gravity Moment Connections
… in two-way unequal depth beam-to-column gravity moment connections, with large eccentricity between the compressive flange forces, are designed for the governing limit state of web compression buckling. This study focuses on finite element modeling of such connections to identify the governing …
-
EXPERIMENTAL TESTING OF NON-EMBEDDED POSITIVE MOMENT CONNECTIONS
… well in service conditions. Although the connections provide sufficient continuity for dead loads which cause negative moments, there has been some concern about the ability of the connections to provide continuity for the positive moments caused by live loads. Cracking has been observed …
-
Experimental Evaluation of Replaceable Shear Fuse Moment Connections
Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …
-
Expedient moment connections for timber portal frame buildings
This thesis introduces an expedient semi-rigid moment connection, the Quick Connect, for use in timber portal frames. The connection is rod based, with components which have easily determinable attributes. Connection components are sized by means of a simple design methodology which has been …
-
Tension bolt behavior in moment connections for seismic applications
… doubts about the performance of the welded moment connection, until now the most popular and reliable steel beam-column connection. A careful study of the structures damaged by these earthquakes, has established that welded connections mainly failed due to fracture along the full penetration …
-
Application of Ductile Yield Link in Glulam Moment Connections
Wood beam-column connections have traditionally been designed as simple shear connections, ignoring their potential moment capacity. A major reason for not utilizing such moment connections is linked to the brittle limit states that wood components exhibit. The purpose of this research was to …
-
Investigation of Double Tee Seismic Moment Connections with HSS Columns
… variation on the prequalified double tee seismic moment connection as a candidate for use in seismic special moment frames using hollow columns. T-stubs are attached to the column by very long bolts passing clear through the hollow center. The column is then filled with grout in the connection …
-
Evaluation of Extended End-Plate Moment Connections Under Seismic Loading
… was conducted to study the extended end-plate moment connections subjected to cyclic loading. Seven specimens representing three end-plate moment connection configurations commonly used in the pre-engineered building industry were used. The connections were designed using yield-line theory to …
-
Behaviour of Blind Bolted Moment Connections for Square HSS Columns
… their use as columns in low or medium-rise moment-resisting steel frames has been limited. Some of the difficulties are due to the lack of a simple and practical field-bolted moment connection between a W-shape beam and an HSS column.</p> <p>The objectives of this research study are to …
-
Moment Connections for Vierendeel Trusses of Square Hollow Structural Sections
… of Vierendeel trusses comprised of semi-rigid connections under panel feint loadings. The semi-rigid connections are made of two unequal width square ESS members welded at right angles. As the flexibility of the joints increases when the width ratio is less than 1.0, the joints are unable to …
-
A Finite Element Investigation of Non-Orthogonal Moment Connections in Steel Construction
… such as the use of non-orthogonally framed connections. Moment frames are seismic force resisting systems that provide architectural liberty when these unconventional designs are encountered. While a braced frame or a structural wall can be more cost efficient, a moment frame allows for the …
-
Evaluating the Fracture Potential of Steel Moment Connections with Defects and Repairs
Steel moment frames are a popular seismic-force resisting system, but it is believed that they are susceptible to early fracture if there is a stress concentration in the plastic hinge region, also known as the protected zone. If a defect is present in this area, it may be repaired by grinding …
-
Unified Design of Extended End-Plate Moment Connections Subject to Cyclic Loading
… design procedures for eight extended end-plate moment connection configurations subject to cyclic/seismic loading. In addition, the suitability of extended end-plate moment connections for use in seismic force resisting moment frames was investigated. Eleven full-scale cyclic and nine monotonic …
-
Evaluation of the Inelastic Rotation Capability of Flush End-Plate Moment Connections
… inelastic rotation capability of flush end-plate moment connections. Seven specimens representing two-bolt and four-bolt flush end-plate configurations were tested under cyclic loading. "Quasi-static" or "slow-cyclic" loading histories suggested by SAC and the Applied Technology Council were used …
-
An Experimental Investigation of Unequal Width HSS Moment Connections for Vierendeel Trusses
… The specimens tested were all unequal width connections and two distinct b/h values were used (0.60 and 0.83). Four specimens were unreinforced while the remaining ten had three distinct reinforcement types. These were branch member flange stiffening plates, chord member top flange stiffeners …
-
Performance Evaluation of Bolted Flange Plate Moment Connections Subjected to Post-Earthquake Fires
… behavior of bolted flange plate special moment frame connections (SMF BFP) under simulated earthquake (cyclic), fire, and post-earthquake events. The experimental investigation was accomplished by using a bolted flange moment connection consisting of one column and one beam which were …