Peak Connection Strength of Reduced Beam Section Moment Frame Connections
In the design of reduced beam section (RBS) moment frame connections, the peak connection strength factor (𝐶𝑝𝑟) is used to estimate the expected maximum moment at the reduced section in the capacity-based design of moment-resisting frames. Current design provisions in AISC 358-22 define C𝑝𝑟 as the …
-
Cyclic Testing of Special Moment Frame Connections With Buckling-Restrained Fuse Plates
… and evaluation of a new special steel moment frame connection that employs replaceable buckling-restrained fuse plates that can enhance seismic performance and post-earthquake repairability. A total of eight unique specimens were tested on two series of beam-to-column subassemblies (W36 …
-
Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses
Special moment frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs. SMFs provide lateral system stiffness without the use of braces that often obstruct views and architectural features. Current American Institute of Steel Construction (ASIC) provisions …
-
Development of a low damage steel frame building incorporating friction based braced and moment frame connections
… benefits of using two types of friction-based connections in steel framed structures of seismically active regions, the Optimised Sliding Hinge Joint (OSHJ) for Moment Resisting Frames (MRF-OSHJ) and the Symmetric Friction Connection (SFC) with Belleville Springs (SFCBeSs) for Concentrically …
-
Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification
Special moment frames having specially detailed connections are common in high seismic regions, providing architectural flexibility for passageways and views without brace obstructions. In situations where the building framing layout requires deviation from typical rectangular framing, skew in the …
-
Optimization of special steel moment frame connection design
Special steel moment frames are one of the most common systems used to resist high seismic forces. Well-proportioned moment resisting connections are essential. Special steel moment frame connections must be capable of transferring moment and shear forces that are developed in the beams to the …
-
Effect of Column Axial Load on Skewed SMF RBS Connection Demands
… of an appropriate seismic steel system (braced frame, moment frame, shear wall, etc.) is often influenced by architectural considerations. Moment frame configurations offer the most architectural flexibility, but are limited by code prequalification requirements that limit the use of …
-
Experimental Testing of Axially Loaded Fuse Plates Without Continuous Buckling Restraint
… loading through strength and ductility. In moment frames, this ductility traditionally comes from inelastic deformation of beams. Moment frame connections move inelastic deformation away from the column and allow a plastic hinge to form in the beam. This plastic hinge prevents collapse but …
-
Reliability Assessment of Alternate Path Method for Structural Steel Connections
… resist the progressive collapse failure. Steel moment frames are used to redistribute the load after a column is notionally removed. This study analyzes connections known as SidePlate, Welded Unreinforced Flanges with Welded Webs (WUF-W), and Reduced Beam Section (RBS), in terms of their ability …
-
Hybrid Steel Frames
… steel systems: hybrid Buckling Restrained Braced Frames (BRBF) and hybrid steel Moment Frames (MF). The "hybrid" term for the BRBF system comes from the use of different steel material including carbon steel (A36), high-performance steel (HPS) and low yield point (LYP) steel. The hybridity of the …
-
LOCATION AND CONFIGURATION OF REDUCED BEAM SECTION CONNECTION EFFECTS ON STRENGTH, STIFFNESS AND DUCTILITY OF MOMENT STEEL FRAMES
Moment resistant frames are mainly used in resisting lateral loads in buildings. During the 1994 Northridge Earthquake, some of these moment steel frame connections could not undergo inelastic deformation which led to many structural damages. New connection systems were proposed and tested which …
-
A Finite Element Study of Non-Orthogonal Bolted Flange Plate Connections
… of life. Steel structures use braced and moment frames to dissipate this energy through various mechanisms. This paper’s focus is on moment frames, and more specifically on Bolted Flange Plate connections with non-orthogonal geometry. With the complexity of designs increasing due to …
-
Experimental Evaluation of Replaceable Shear Fuse Moment Connections
Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …
-
A comparison of Reduced Beam Section moment connection and Kaiser Bolted Bracket® moment connections in steel Special Moment Frames
… force resisting systems in practice today, the Moment Frame has most diverse connection types. Special Moment frames resist lateral loads through energy dissipation of the inelastic deformation of the beam members. The 1994 Northridge earthquake proved that the standard for welded beam-column …
-
Performance Evaluation of Bolted Flange Plate Moment Connections Subjected to Post-Earthquake Fires
… behavior of bolted flange plate special moment frame connections (SMF BFP) under simulated earthquake (cyclic), fire, and post-earthquake events. The experimental investigation was accomplished by using a bolted flange moment connection consisting of one column and one beam which were …
-
Multi-Hazard Resilience of Steel MRF Buildings
… framing, but vary in the design of the perimeter moment resisting frames (MRFs). Detailed 3D FEM building models were developed in ABAQUS in order to more adequately simulate real-building behavior. The framing members are modeled using beam elements and the composite floor slabs are modeled as …