Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 83 for “"Moment resisting frame"”.
-
LATERAL LOAD PATTERNS FOR THE CONCEPTUAL SEISMIC DESIGN OF MOMENT-RESISTING FRAME STRUCTURES
… patterns for the conceptual seismic design of moment-resisting frame structures. The proposed lateral load patterns are based on inelastic behavior and are a fundamental component of a proposed seismic design methodology to limit the extent of structural damage in the system and distribute this …
-
Seismic Response of Acceleration-sensitive Nonstructural Components Mounted on Moment-resisting Frame Structures
… supported on elastic and inelastic regular moment-resisting frame structures is presented. The response of a variety of stiff and flexible frame structures (with 3, 6, 9, 12, 15, and 18 stories) subjected to a set of 40 far-field ground motions are evaluated. The NSCs under consideration are …
-
Seismic retrofit of existing reinforced concrete moment resisting frame structures using diagonal prestressing
… experimentally that a 1 bay, 1 storey R/C frame with masonry infill panels, designed based on the ACI 318-1963 building code, hence seismically deficient, could be retrofitted with prestressed cables to reduced lateral drift. In addition, analytical modeling of the 1 storey frame and …
-
Evaluation of the seismic level of protection of steel moment resisting frame building structures
… of low and medium-rise buildings have steel moment resisting frames as the primary lateral load resisting system. During the past few decades, much confidence has been placed on this type of structural system for resisting seismic loads. However, after recent earthquakes (e.g. Northridge, …
-
Seismic design and performance of steel moment resisting frame buildings designed using NBCC 2005
… of five, ten, fifteen and twenty storey steel moment resisting frame buildings designed according to the seismic provisions on NBCC 2005. A series of static and dynamic analyses have been carried out to evaluate their performance. It has been observed that the assumed ductility capacity in the …
-
Comparative response of mid-rise (9-story) based-isolated and conventional steel moment resisting frame buildings
Base isolation systems are preferably applied in low-rise buildings since the vibration period of the structure can be shorter, so that it performs more rigidly to maximize the benefit from the isolation system. Mid-rise and high-rise base-isolated buildings are expected to have different and …
-
Development of an Innovative Hybrid Timber-Steel Moment-Resisting Frame for Seismic-Resistant Heavy Timber Structures
… seismic performance of a new hybrid timber-steel moment-resisting connection for mid-rise heavy timber structures. This system consists predominantly of timber members, but utilizes a steel yielding link at the beam-column joint that improves seismic performance by replacing connection components …
-
Strain Rate Effects on a Ductile Moment Resisting Frame with RBS Connection Subjected to Seismic Ground Motions
… different combinations on beams and columns of moment resisting frame (MRF) with RBS to conduct non-linear dynamic analyses subjected to earthquake records at different seismic hazard levels in ABAQUS. The maximum bending moment at different locations of MRF and maximum base shear are found to …
-
Seismic resilience and performance design approach for concrete moment resisting frame buildings equipped with yielding restrained braces
… load before yielding occurs in members of a frame, which dissipate a major part of energy. It saves the initial cost of a new construction or retrofitting of an existing building, where the dampers provide a very high energy dissipation. Even though damping devices can provide supplemental …
-
Impact of friction dampers and ductility factor on the seismic response of concrete moment resisting frame buildings
… fiction dampers was observed by the reduction of moment and shear on columns, the reduction of cost. Six structures were designed for this study: elastic with and without dampers, moderately-ductile with and without dampers and ductile with and without dampers. This study demonstrates that by …
-
Displacement-based design of reinforced concrete moment resisting frame incorporating cross laminated timber infill and metallic damper connectors
… hybrid structure consists of reinforced concrete frame incorporated with Cross Laminated Timber (CLT) and metallic damper connections. The seismic design of this proposed system was carried out with the displacement-based design framework and the design was successfully verified. First, this study …
-
Direct displacement-based design and seismic performance assessment of novel hybrid moment-resisting frame structures fitted with various hysteretic damping devices
… model to simulate the behaviour of the designed frame was validated by calibrating the hysteretic behaviours of the numerical models with results from an experimental model which was tested during the development of this modified direct displacement-based design procedure. After the validation of …
-
Seismic risk assessment of code-conforming reinforced concrete moment resisting frame buildings : consideration of unreinforced masonry infill wall and soil-structure interactions
… vulnerability of reinforced concrete (RC) frames with unreinforced masonry (URM) infill walls has been a concern in areas with high seismic activity. The seismic response of this structural system is usually modelled in the form of global building analysis using simplified procedures …
-
Performance evaluation of friction damped braced steel frames under simulated earthquake loads
… proposed in order to improve the response of Moment Resisting Frames and Braced Moment Resisting Frames during severe earthquakes. The system basically consists of a special inexpensive mechanism containing friction brake lining pads introduced at the intersection of frame cross-braces. The …
-
Fundamental period of vibration for reinforced concrete buildings.
… and measured values is obtained. For the moment-resisting frame buildings, the current codes estimation of the fundamental period translate into a conservative values of the design base shear forces. However, when the non-structural elements contribute to the overall stiffness of the …
-
ROBUST DESIGN OPTIMIZATION: ENSURING ROBUSTNESS AGAINST UNCERTAINTY IN STRUCTURAL DESIGN
… in foundation design and seismic demand in steel moment resisting frame design are the considered performance measures. These measures, in turn, lead to a confidence level based robust design optimization, second order reliability based design optimization, and robust design optimization of steel …
-
Effect of Torsional Ground Motion Component on Floor Acceleration Response in Flexible SMRF Buildings
… floor acceleration response of flexible special moment resisting frame (SMRF) buildings. For this purpose, computational models of three SMRF buildings were subjected to far-field ground motions with and without TGMs. Accordingly, the effect of TGM on the floor acceleration response of …
-
Παραμετρική ανάλυση και βελτιστοποίηση συνδέσεων χαλύβδινων πλαισίων με δοκούς μειωμένης διατομής
… for the design of Reduced Beam Section steel moment resisting frame connection under monotone and cyclic loading, utilizing profiles and design aspects of the European industry and practice. The whole scheme leads to a mathematical rule, which may lead to the optimal choice of joint geometric …
-
Development of Multiobjective Optimization Procedures for Seismic Design of Steel Moment Frame Structures
… of code-compliant regular plane steel special moment resisting frame structures with simultaneous as well as separate treatment of multiple objective functions that reflect steel material usage, initial expenses, degree of design complexity, seismic structural performance indices, and lifetime …
Page 1 of 5