Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"Monitoring Mode"”.
-
The use of Envisat ASAR Global Monitoring Mode data to map rapid broad-scale flood events
… the Envisat satellite, operating in Global Monitoring Mode (GM), is targeted for particular consideration due to its high temporal frequency, comprehensive coverage and ease of acquisition. Challenges are identified which relate both to the use of radar generally, and also in particular to …
-
Paper spray mass spectrometry for rapid drug screening
… were spiked into drug-free blood, and by monitoring two fragment ion channels in selected reaction monitoring mode, as well as the ratio between the two fragment ions, a method was developed capable of detecting over 120 drug and drug metabolites at concentrations relevant to postmortem …
-
A residue study of permethrin on tomato plants
… spectrometer operating in the selected ion monitoring mode.</p><p>The results of this study showed that permethrin residues underwent rapid decline during the first two to three days after application, declined at a much slower rate thereafter, and did not seem to be affected by the …
-
Accurate and sensitive determination of selected contaminants from food packaging materials
… ionization (ESI) using the multi-reaction monitoring mode. The well validated methods in this thesis have allowed for efficiency and convenience for food surveillance institutions.
-
The Combination of Microbore Liquid Chromatography and Mass Spectrometry
… performance under scanning and selected ion monitoring modes were tested using the PAH standard.</p> <p> A marine sediment extract was subjected to qualitative and quantitative analysis for PAH. Qualitative results on the sample were obtained from a combination of retention indices, mass …
-
The Analysis of Nitro Polycyclic Aromatic Hydrocarbons in Diesel Exhaust and Urban Airborne Particulate Samples
… by capillary column GC-MS in the selected-ion-monitoring mode and other compounds were identified by capillary column GC-MS in the full scanning mode of operation.</p> <p>Nitro-PAHs including 1-nitropyrene, nitro(phenanthrenes/anthracenes), methylnitro(phenanthrenes/anthracenes), …
-
COMPARING OUTCOMES OF DRIED BLOOD SPOT AND PLASMA VIRAL LOAD MONITORING FOR HIV TREATMENT IN RESOURCE-LIMITED SETTINGS USING A MARKOV STATE-TRANSITION MODEL
… alternative. A Markov state-transition model was created in order to better evaluate the clinical consequences of this alternative. Outcomes were compared to those of plasma viral load, CD4 immunologic criteria, and clinical criteria for treatment failure. Methods: A Markov …
-
Advanced Techniques in Mass Spectrometry for Qualitative and Quantitative Protein Characterization
… mass spectrometer operating in selected reaction monitoring mode, a method has been developed for the absolute quantitation of the <em>Clostridium thermocellum</em> cellulosome protein machine in samples ranging in complexity from purified cellulosome samples to whole cell lysates as an …
-
Classification of Wireless Device Location Based on Wi-Fi Metadata
… can be obtained by deploying a network of monitoring devices over Wi-Fi. Monitoring devices consist of network interface cards in monitoring mode and are capable of listening to all Wi-Fi packets in the network traffic. This thesis examines the problem of estimating the occupancy of a …
-
The Role Of Polycyclic Aromatic Hydrocarbon (pah) Metabolites In Endometrial Cancer
… mass spectrometry in the selected reaction monitoring mode, I analyzed B[a]P metabolism in Ishikawa cells. Estrogenic activity of B[a]P metabolites was determined by the endogenous estrogen inducible alkaline phosphatase reporter gene and an exogenous estrogen response element (ERE) …
-
Atmospheric Concentrations of Selected Insecticides and Current Use Herbicides in Saskatchewan
… spectrometry in negative ion selected ion monitoring mode. Atmospheric concentrations of three high usage pre-emergent herbicides (triallate, trifluralin, and ethalfluralin) in the Canadian prairies showed increasing atmospheric concentrations in spring-early summer when they were …
-
Strategic Examination of the Revising and Editing Components of the Process Approach to Written Language Employing Auditory/Oral Feedback Techniques
… texts into a tape recording utilizing the monitoring mode for immediate feedback and evaluation. Chapter Four reveals statistically significant gains on the revising subsets but not editing subsets. Holistic measurement was statistically significant as a result of the revising component. …
-
Pharmacokinetics and tissue withdrawal study of tulathromycin in North American bison (Bison bison) and white-tailed deer (Odocoileus virginianus) using liquid chromatography-mass spectrometry
… at m/z 403.9 and monitored in selected ion monitoring mode. Tulathromycin demonstrated early maximal serum concentrations, extensive distribution, and slow elimination characteristics in deer and bison. In bison, mean Cmax (195 ng/mL) was lower compared to cattle (300 to 500 ng/mL) and …
-
Development of a bioanalytical method for the quantitative analysis of cannabinoids and their metabolites in plasma
… Q-Exactive plus platform in parallel reaction monitoring mode (PRM). One quantitative product ion and one qualitative product ion were monitored for each cannabinoid. Validation was carried out according to FDA guidelines on validation of bioanalytical methods. The method was found to be …
-
Comparing predefined derivatisation parameters for GC-MS analysis of selected organic acids
… and analysed using GC-MS in single ion monitoring mode. Data were processed, and statistical comparisons were performed. Coefficient of variance (CV) was used as the main performance criterion in this study and used as a mean to compare the results. Between conventional thermal- and …
-
Determination of nicotine and its metabolites by capillary electrophoresis and mass spectrometry.
… The added selectivity that the selected ion monitoring mode of MS provided ensured the clear identification of nicotine and its metabolites in urine. A counterflow transient isotachophoresis (tITP) method was developed, with MS detection, for the analysis of even lower analyte concentrations. …
-
Structurally integrated luminescence based oxygen sensors with Organic LED/ oxygen sensitive dye and PECVD grown thin film photodetectors
… sensor and sensors with a reliable and accurate monitoring of oxygen concentration in controlled environments requiring measurements under low oxygen concentration. This work has been devoted to the development of structurally integrated luminescence quenching based sensors, the structure …
-
Ανάπτυξη και βελτιστοποίηση μεθόδων ειδοπροσδιορισμού κασσιτέρου με συνδυασμένες τεχνικές χρωματογραφίας και φασματομετρία μάζας
… as TeET peaks was performed by the selective ion monitoring mode (SIM). The precision of the proposed method is satisfactory providing RSD values below 10% for both tin species and good linearity up to 10 µg L-1. The proposed HS-SPME-GC-MS method was successfully applied to the determination of …
-
Nástroje pro monitorování rádiových sítí
Bakalářská práce zkoumá detekci aktivních WiFi a Bluetooth zařízení prostřednictvím mini počítače Raspberry Pi s využitím softwaru Kismet. Monitorování probíhá v pásmech 2,4 GHz a 5 GHz. V práci jsou detailně rozebrány principy fungování těchto technologií a metody jejich možné detekce. Získané …
-
Development of Mass Spectrometry Based Methods and Sample Preparation Strategies for the Analysis of Pesticides, Hormones, Metals, and Biomarkers of Endocrine Disruption in the Environment
… chemicals. Scheduled selected reaction monitoring acquisition assured the optimum sensitivity of trace analysis. Electrospray positive and negative ionization were performed in single run by using wrong-way-round ionization at high pH condition. The validated method was applied to river …
Page 1 of 2