Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 11 of 11 for “"Mononobe-Okabe"”.
-
Seismic response of displacing and non-displacing retaining systems: new insights
… with the analytical methods (Chapter 11) of: Mononobe Okabe (M O),Seed & Whitman new modification (S W),EC8 [Annex F (prEN 1998-5:2022E) based on Lancellotta’s (2002, 2007) equations],Mylonakis et al. (2007),Kapila’s (1962) Mononobe-Okabe (M O K),RUIGA (proposed method),Veletsos & Younan …
-
Seismic response of retaining structures
… sliding increases and can be greater than the Mononobe-Okabe value when sliding is prevented from occurring.
-
Dynamic response of soil-wall systems
… methods of analysis; specifically, the Mononobe-Okabe method and its extension by Richards and Elms. Following a detailed review of these methods and of their underlying assumptions, comprehensive numerical data are presented that elucidate the effects and relative importance of the …
-
Passive Earth Pressures on a Pile Cap with a Dense Sand Backfill
… with cyclic/dynamic losses without damping, the Mononobe-Okabe (M-O) equation with a 0.75 or 0.8 multiplier applied to the peak ground acceleration can be used to obtain a reasonable estimate of the force. When including increases in resistance due to damping, a 0.6 multiplier can similarly be …
-
Scale Model Shake Table Testing of Seismic Earth Pressures in Soft Clay
… are not pronounced. The simplified Monnobe-Okabe method was also evaluated in this study. Although the Mononobe-Okabe method may be inappropriate for cohesive soils, a seismic coefficient of about 1/10 the PGA was back-calculated from empirically measured earth pressures. The results of this …
-
Seismic assessment of basement walls in British Columbia
… of basement walls in Vancouver is based on the Mononobe-Okabe (M-O) method using a Peak Ground Acceleration (PGA) mandated by the National Building Code of Canada (NBCC, 2010). Because there is a little evidence of any significant damage to basement walls during major earthquakes, the Structural …
-
Seismic Performance of Geosynthetic-Soil Retaining Wall Structures
… guidelines. The comparison shows that current Mononobe-Okabe (M-O) based analysis methods could not consistently satisfactorily predict measured reinforcement connection load distributions at all elevations under both static and dynamic loading conditions. The results from GRS model wall tests …
-
Análisis de estabilidad de muros de contención de acuerdo a las zonas sísmicas del Perú
… en voladizo, al aplicar el método empírico de Mononobe-Okabe, así como el método General de Equilibrio Límite (GLE); con ellos se busca determinar la respuesta sísmica y la variación de esta con respecto a las distintas zonas sísmicas del Perú. Finalmente, al interpretar los resultados …
-
Active earth pressure from c-Ø soil subjected to surcharge and seismic loadings
… presented by Coulomb (1776) and Rankine (1857). Mononobe-Okabe equation was developed during 1926-1929 for calculating total active earth pressure from cohesionless soil (f soil) backfills. In recent past, attempts have been made to develop analytical expressions for the total seismic active …
-
Determination of Seismic Earth Pressures on Retaining Walls Through Finite Element Analysis
… have been derived based on the original work of Mononobe and Okabe, who used a shake table to calculate dynamic pressures of displacing retaining walls existing in cohesionless soils. Since this original work was done over eighty years ago, the results of Mononobe and Okabe, colloquially known as …
-
Diseño de Muros de Contención para Estructuras Aisladas en Zonas de Alto Peligro Sísmico: Bajo una Aceleración Sísmica con Periodo de Retorno de 2500 años
En el Perú, el uso de sistemas de aislamiento sísmico en la construcción de edificios ha ganado relevancia debido a la alta actividad sísmica de la región. Estos sistemas permiten una mayor versatilidad ante el movimiento sísmico. Sin embargo, para proteger adecuadamente estos sistemas, se …