Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 35 for “"Monte Carlo Codes"”.
-
Inelastic electronic cross Section modelling of Protons in liquid Water for radiobiology Studies with Monte Carlo Codes
… of proton in liquid water, with application in Monte Carlo simulation codes for radiation biophysics and radiobiology. The research focuses on modelling the electronic interaction processes that are relevant in proton irradiation of liquid water: ionisation and excitation by both protons and …
-
Modeling and maximum theoretical efficiencies of linearly graded alphavoltaic and betavoltaltaic cells
… as alphavoltaic and betavoltaic cells using Monte Carlo codes. Two Monte Carlo codes were used for alpha particles: SRIM/TRIM and GEANT4 codes. The models examined the transport of 5.307 MeV alpha particles emitted by Polonium-210. Energy deposition in a 1 [mu]m depletion region of SiC was …
-
Δοσιμετρία ασθενών κατά τις επεμβατικές ακτινολογικές εξετάσεις με τη χρήση λογισμικού προσομοίωσης Monte Carlo
… simulating the interventional procedures with Monte Carlo codes. The used Monte Carlo codes were MCNP5 and PCXMC2.0. There were used two codes in order to increase the accuracy of the calculations.The mean DAP values of the male (n=20) and female (n=23) group that underwent in PTC were …
-
Characterization of the Cosmic Ray Telescope for the Effects of Radiation (CRaTER) detector
… Transfer (LET) database using three-dimensional Monte Carlo methods. This is the first database suitable for supporting CRaTER's mission, by comparing what will be measured in space with Monte Carlo codes based models.</p>
-
PXMORSE : a continuous energy Monte Carlo code
<p>PXMORSE, a continuous energy version of the Monte Carlo radiation transport code MORSE-SGC, has been developed. PXMORSE solves the Boltzmann transport equation using detailed energy and angular data from the ENDF/B-V data base. Outside of the unresolved region, cross sections are represented by …
-
A feasibility study of small modular reactor(SMR) power-performance optimisations based on the SMART system
… This thesis has used the stochastic method Monte Carlo codes MONK and OpenMC to investigate the neutronic related behaviours and assess the proposed optimisations. The numerical models based on both codes have been validated and verified, especially to the open-source code OpenMC. The …
-
The use of the Monte Carlo technique in the simulation of small-scale dosimeters and microdosimeters
… with an energy of 5-50 keV. In addition to this, Monte Carlo models were constructed of the different detector designs in order to ascertain the trends in energy absorption within the detectors. An important part of the research was investigating the dose enhancement effects produced when the low …
-
Discrete ordinates CT organ dose simulator (DOCTORS)
… the dose to patients is computed using Monte Carlo methods and experimental tests. In other areas of radiation transport, deterministic codes have been shown to be much faster than Monte Carlo codes.</p><p>Currently, no deterministic methodology exists to automatically generate a …
-
Modeling and Simulation of High-Field, High-Temperature SiC Devices
… the extraction of SiC material parameters using Monte Carlo codes. Results of this study show that despite favorable material characteristics. there are inherent problems associated with SiC. Many parameters obtained using Monte Carlo simulations are new additions to the SiC literature. These …
-
Application of deterministic 3D SN transport driven dose kernel methods for out-of-field dose assessments in clinical megavoltage radiation therapy
… increasingly important. Currently, full physics Monte Carlo calculations for dose calculations have been regarded as a ‘gold standard’ for dose assessments of the target and OAR (organ at risk). However, these Monte Carlo calculations require very long computation times. The current treatment …
-
Validation of Raptor and Analysis of Cross-Section Generation Techniques with the MHTGR 350MWt Core
… Special treatment must be taken in deterministic codes and the large number of particles can cause a large computational cost in Monte Carlo codes. Considerable effort has been made in benchmarking codes on high temperature gas reactors. Ultra Safe Nuclear Corporation (USNC) has made a tool called …
-
Photon dose calculations in inhomogeneous media
… weighting the primary and scatter components and Monte Carlo simulation was used to verify these results. A calculation code was written and an optimization technique was devised reducing the computation time to a practical limit while maintaining accuracy. An additional topic on the subject of …
-
Fission Multiplicity Distribution Sampling in MCNP6 Criticality Calculations
… of the incident neutron energy. In general, Monte Carlo codes used for criticality calculations do not use explicit fission multiplicity sampling instead opting for the expected-value outcome approach. As computational methods and resources advance, there is growing interest in high fidelity …
-
Ανάπτυξη πυρηνικών τεχνικών στοιχειακής ανάλυσης δειγμάτων μεγάλου όγκου
… sample geometry were simulated in detail using Monte Carlo codes and the results of the simulations were compared against experimental measurements. Furthermore, the study was focused on the analysis of large inhomogeneous samples and the evaluation of the inhomogeneity effect on the analysis …
-
Step IV of the muon ionization cooling experiment (MICE) and the multiple scattering of muons
… programme.</p> <p>Cooling predictions in Monte Carlo simulations of Step IV were found to disagree with the predictions of the 'cooling formula', a widely-used approximation, by up to 30% in liquid hydrogen (LH2). This disagreement was shown to originate, largely, from the multiple …
-
Multi-Physics Modeling and Simulations of Heat Pipe Cooled Graphite Moderated Micro Reactor
… the design was developed using MCNP and Serpent Monte Carlo codes, in order to calculate important parameters including criticality, control devices worth, power distribution, and temperature reactivity coefficients. The thermal conduction model of the solid-state core was developed and coupled …
-
Dosimetry and clustering properties of energy deposition from beta particles emitted by H-3 and C-14 in the nucleus of a mammalian cell
… of dose deposited by electron track ends. A Monte Carlo electron track-structure code was used as the primary tool for solving these problems. Comparisons of results produced by three different Monte Carlo codes in terms of energy deposition in spherical volumes showed good agreement. …
-
Automated Doppler Broadening of Cross Sections for Neutron Transport Applications
… In particular, methods will be added to the KENO Monte Carlo code.</p> <p>Areas of interest include: neutron scattering off of heavy isotopes in the epithermal energy range, implementation of Doppler pre-broadening of continuous energy one-dimensional cross-section data, implementation of …
-
Analysis and interpretation of gamma-ray burst continuum spectral evolution with BATSE data
… plasma as the emission mechanism. With our Monte Carlo codes, we have begun the generation of a library of inverse Compton spectra. Using them, we have made preliminary fits to two bursts with prompt multiwavelength data. The characteristic "terrace-shaped" Compton spectrum is evident in …
-
FIRST experiment: measurements of differential cross sections in 12C fragmentation for hadron-therapy and space applications
… ions are urgently needed for improving transport codes to be used in cancer therapy. Algorithms that deal with the transport of charged particle in matter are essential for accurate treatment plannings, in order to evaluate possible long term side effects of dose released in healthy tissue. …
Page 1 of 2