Results 1 to 20 of 56 for “"Monte Carlo calculation"”
-
Monte Carlo calculation of electron multiple scattering in thin foils
The electron photon transport code ITS has many applications in the physics and medical industries. The code was originally intended for the use in determining particle transport in think materials. The code breaks down for very thin targets because the multiple scattering approximation used to …
-
A generalized approach to the biased adjoint Monte Carlo calculation
<p>The application of the forward (or adjoint) Monte Carlo method to the solution of deep-penetration radiation transport problems requires the use of a biasing technique such as "importance sampling". A systematic approach to obtain the importance information is to solve the adjoint (or forward) …
-
A Monte Carlo calculation of neutron reflection from various curved surfaces
… of a solid reflector are studied with the Monte Carlo method. The geometries studied are cylindrical, parabolic, and hemispherical. It is shown that when the curved surface is cylindrical, a small "focusing effect" occurs in the reflected neutron beam. Parabolic and hemispherical surfaces …
-
A Monte Carlo calculation of the resonance escape probability of thorium in a homogeneous reactor
… in the high energy range; therefore, a water Monte Carlo serves adequately as the neutron supply to the resonance region of thorium. In order to find an escape probability we determine the ratio of the number of neutrons that attain energies below the resonance region to the number that appear …
-
MCNP-DSP : a neutron and gamma ray Monte Carlo calculation of source-driven noise-measured parameters
… parameters that can be used for verification of calculation models and cross section data. A certain ratio of spectral densities, <em>R(ω)</em>. obtained from the measured spectra is independent of detection efficiency and in some cases source intensity. MCNP-DSP was developed from the Monte …
-
Monte Carlo calculation and analysis of neutron and gamma fields at spallation neutron sources for simulating cosmic radiation
… SEE testing has become the purpose of this work. Monte Carlo calculation of radiation fields at spallation neutron source was used to characterize neutron and gamma energy spectra for accelerated single event effect testing. Geant4 (GEometry ANd Tracking version 4) toolkit, using Monte Carlo …
-
ABSOLUTE MEASUREMENT OF IONIZATION CROSS SECTIONS IN COLLISIONS BETWEEN RYDBERG SODIUM ATOMS.
… agreement with a recent classical trajectory Monte Carlo calculation but differ greatly from an earlier indirect measurement.
-
Stopping Cross-Sections in Carbon of Low-Energy Atoms With Z ≤ 12
… in the experiments. Chapter III describes the Monte Carlo calculation used to reduce our data to information of a general form. Chapter IV contains the experimental results and Chapter V compares the results with existing data and theory.</p>
-
Search for magnetic monopoles possibly produced by proton-antiproton collisions at the Tevatron collider.
… cross section based on a Drell-Yan model and Monte Carlo calculation.
-
A Monte Carlo analysis of neutron thermalization in graphite
… using the pulsed source method. This thesis is a Monte Carlo calculation of the results to be expected in such an experiment. The neutron flux and energy spectrum was calculated at 1, 2, 5, and 10 microseconds after a burst of fast neutrons. The neutrons were “tracked" to thermal and the Fermi Age …
-
IMAGE RECONSTRUCTION DEVELOPMENT AND SIGNAL-TO-NOISE ANALYSIS FOR NANOMETER-SCALE MAGNETIC RESONANCE IMAGING
… three-dimensional image within a few minutes of calculation, but compromises the image signal-to-noise ratio by creating false peaks in the resulting image. This problem of false peaks is resolved by a third reconstruction scheme based on Bayesian Monte Carlo calculation, capable of producing …
-
The Kinematics of Rydberg Atom - Sulfur Hexafluoride Collisions
… and the data compared to the results of a Monte Carlo calculation. These comparisons indicate that few electron transfer reactions lead to significant energy transfer to the Rydberg ion core, implying that the observed long lifetime of the SF(,6)('-) ion is a consequence of the very low …
-
Delayed neutron emission measurements for U-235 and Pu-239
… accurately from a thermal fission reaction. A Monte Carlo calculation using the Geant4 code was used to demonstrate the neutron energy independence of the detector used in the counting station. A set of highly purified actinide samples (U-235 and Pu-239) was irradiated in these experiments by …
-
Quantum Monte Carlo for Nuclear Physics: On and Off the Lattice
… energy of a nuclear-many system in a Diffusion Monte Carlo calculation. Higher perturbative corrections are difficult to calculate in most \textit{ab initio} many-body methods since they are usually concerned with calculating only the ground state energy. By mapping the calculation of the …
-
Characterizing ionization chamber dosimetry in inverse planned IMRT fields
… in radiation therapy to have two independent calculations for the number of monitor units used in patient treatment plans. The relationship between monitor units and absorbed dose to water is sophisticated for MLC-based IMRT. Verification measurements of absorbed dose to water with ionization …
-
A hybrid stochastic/deterministic method for transient, three-dimensional neutron transport
… technique is utilized with a Monte Carlo code embedded inside of a quasi-static kinetics framework. The time-dependent flux amplitude, which is usually rapidly varying, is computed deterministically by a conventional point kinetics algorithm. The point kinetics parameters, …
-
Development of a New Monte Carlo reactor physics code
Monte Carlo neutron transport codes are widely used in various reactor physics applications, traditionally related to criticality safety analyses, radiation shielding problems, detector modelling and validation of deterministic transport codes. The main advantage of the method is the capability to …
Page 1 of 3