Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 90 for “"Motion Artifact"”.

  1. Motion Artifact Reduction in Impedance Plethysmography Signal

    … studies addressing the problem of removing motion artifact from the electrocardiogram (ECG) and photoplethysmography (PPG) signals in the past few years. However, no such study exists for the Impedance Plethysmography (IP) signal. The IP signal can be used to monitor respiration in mobile …

    vcu Repository record for Motion Artifact Reduction in Impedance Plethysmography Signal (opens in a new tab)

  2. Motion Artifact Processing Techniques for Physiological Signals

    … performed in the hospital environment, artifacts continue to be a major issue for these systems. The magnitude and frequency of artifacts can vary signi�cantly depending on the recording environment with one of the major contributions due to the motion of the subject or the recording …

    maynooth Download PDF for Motion Artifact Processing Techniques for Physiological Signals (opens in a new tab)

  3. Motion Artifact Evaluation of Coronary CT Angiography Images

    … and validate an automated algorithm to quantify motion artifact level on coronary CT angiography (CCTA) images. Unlike existing motion artifact reduction techniques that evaluate the relative level of motion artifacts within one exam, this dissertation aims to quantify the absolute level of …

    marquette Repository record for Motion Artifact Evaluation of Coronary CT Angiography Images (opens in a new tab)

  4. Motion artifact reduction of electrocardiograms using multiple motion sensors

    … ECG signal, the most problematic being that of motion artifacts. As an individual wearing a surface ECG moves, their movements will add noise to the signal. This noise is particularly difficult to remove, as it will change depending on the movements of the user and will often fall in the same …

    sask Repository record for Motion artifact reduction of electrocardiograms using multiple motion sensors (opens in a new tab)

  5. Motion Artifact Reduction From Non-Contact ECG Recording Systems

    … use. However, a significant challenge remains; motion artifacts (MAs) caused by body movements and physiological vibrations. Such artifacts can significantly compromise diagnostic accuracy and may even lead to misinterpretations of cardiovascular conditions. To address this, this PhD research …

    auckland-tech Repository record for Motion Artifact Reduction From Non-Contact ECG Recording Systems (opens in a new tab)

  6. Tensor Decomposition for Motion Artifact Removal in Wireless ECG

    … noise source in mobile ECG is examined: Motion artifacts. We study the spectral characteristics of motion artifacts for a set of different motions representing everyday activities, namely: standing up, bending forward, walking, running, jumping, and climbing stairs. Furthermore, we …

    qucosa-diss

  7. Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research

    … associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we …

    carleton Repository record for Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research (opens in a new tab)

  8. Drawn-On-Skin Liquid Electrodes for Motion Artifact-Free Neurological Signal Recording

    … and electromyogram (EMG) successfully, without motion artifacts caused by movement induced deformation at the skin-electrode interface when compared to conventional electrode types. In applying the DoS electrode system, along with the implementation of protective insulation and encapsulation, a …

    houston Repository record for Drawn-On-Skin Liquid Electrodes for Motion Artifact-Free Neurological Signal Recording (opens in a new tab)

  9. Use of Motion Artifact for the Detection of Respiratory Effort in Polysomnography

    … respiratory effort by using the movement artifact found in the electromyographic (EMG) and electrocardiographic (ECG) recordings used in polysomnography was investigated. The resulting signals were compared to effort measured with respiratory inductance plethysmography (RIP). The EMG and …

    houston Repository record for Use of Motion Artifact for the Detection of Respiratory Effort in Polysomnography (opens in a new tab)

  10. Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact

    … applications, pulse oximetry is susceptible to motion artifact contamination. This thesis presents efforts to quantify and model the effects of motion artifact, and automatically detect periods of poor signal quality. First, the effects of motion artifact on SpO2 are analyzed using motion …

    carleton Repository record for Signal Quality Analysis in Pulse Oximetry: Modelling and Detection of Motion Artifact (opens in a new tab)

  11. Understanding the Mechanisms by which Cable Sway Produces Motion Artifact in Mobile Electroencephalography

    … during human walking in dynamic environments. Motion artifact from cable sway affects the quality of EEG signals collected from the scalp, masking contributions of synchronously firing neurons. Previous studies have explored cable sway-induced motion artifact, but only during vigorous exercise …

    ucf Repository record for Understanding the Mechanisms by which Cable Sway Produces Motion Artifact in Mobile Electroencephalography (opens in a new tab)

  12. Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping

    … increasingly rely on methods that can overcome motion, extract multiple tissue parameters efficiently, and provide clinically meaningful biomarkers. Across the brain and liver, motion compensation, multi-parametric mapping, and susceptibility-based tissue characterization remain key challenges. …

    cornell Repository record for Advanced Methods For Magnetic Resonance Image Reconstruction, Motion Artifact Correction And Quantitative Susceptibility Mapping (opens in a new tab)

  13. System Design And Motion Artifact Removal Algorithm Implementation For Ambulatory Women Ecg Measurement System:e-Bra System

    … P waves QRS complex, and T wave, but also a motion artifact component (MA) due to subject movements. The MA component is one of the reasons for misdiagnosis. Therefore, the main purpose of the E-Bra system is to provide a reliable ECG data set identical to the quality of an ECG data set …

    arkansas Repository record for System Design And Motion Artifact Removal Algorithm Implementation For Ambulatory Women Ecg Measurement System:e-Bra System (opens in a new tab)

  14. Evaluation of automated hippocampal segmentation software in a clinically heterogeneous sample

    … the most robust results in the presence of motion artifact, a common problem in MR, and visible anatomic anomalies of the hippocampi. MRI data included in the current study was obtained from residents of Vancouver B.C’s Downtown Eastside (DTES) social housing projects, the majority of whom …

    ubc Repository record for Evaluation of automated hippocampal segmentation software in a clinically heterogeneous sample (opens in a new tab) Download PDF for Evaluation of automated hippocampal segmentation software in a clinically heterogeneous sample (opens in a new tab)

  15. The Removal Of Motion Artifacts From Non-invasive Blood Pressure Measurements

    … These measurements are very sensitive to motion of the patient or the surroundings where the patient is. The slightest unexpected movements could offset the readings of the automatic Blood Pressure meter by a large amount or render the readings totally meaningless. Every effort must be …

    ucf Repository record for The Removal Of Motion Artifacts From Non-invasive Blood Pressure Measurements (opens in a new tab)

  16. High-Speed Dual-Wavelength Optical Polarimetry for Glucose Sensing

    … time – while compensating for time-varying motion artifact due to corneal birefringence. This research is made up of three goals. The first goal is to design and construct a high-frequency, ferrite core Faraday rotator that can both rotate and modulate linearly polarized light in a frequency …

    tamu Repository record for High-Speed Dual-Wavelength Optical Polarimetry for Glucose Sensing (opens in a new tab)

Page 1 of 5