  1. Motion Artifact Reduction in Impedance Plethysmography Signal

    … studies addressing the problem of removing motion artifact from the electrocardiogram (ECG) and photoplethysmography (PPG) signals in the past few years. However, no such study exists for the Impedance Plethysmography (IP) signal. The IP signal can be used to monitor respiration in mobile …

    vcu Repository record for Motion Artifact Reduction in Impedance Plethysmography Signal (opens in a new tab)

  2. Motion artifact reduction of electrocardiograms using multiple motion sensors

    … ECG signal, the most problematic being that of motion artifacts. As an individual wearing a surface ECG moves, their movements will add noise to the signal. This noise is particularly difficult to remove, as it will change depending on the movements of the user and will often fall in the same …

    sask Repository record for Motion artifact reduction of electrocardiograms using multiple motion sensors (opens in a new tab)

  3. Motion Artifact Reduction From Non-Contact ECG Recording Systems

    … use. However, a significant challenge remains; motion artifacts (MAs) caused by body movements and physiological vibrations. Such artifacts can significantly compromise diagnostic accuracy and may even lead to misinterpretations of cardiovascular conditions. To address this, this PhD research …

    auckland-tech Repository record for Motion Artifact Reduction From Non-Contact ECG Recording Systems (opens in a new tab)

  4. Motion Artifact Evaluation of Coronary CT Angiography Images

    … and validate an automated algorithm to quantify motion artifact level on coronary CT angiography (CCTA) images. Unlike existing motion artifact reduction techniques that evaluate the relative level of motion artifacts within one exam, this dissertation aims to quantify the absolute level of …

    marquette Repository record for Motion Artifact Evaluation of Coronary CT Angiography Images (opens in a new tab)

  5. Heart Rate Artifact Suppression

    Motion artifact strongly corrupts heart rate measurements in current pulse oximetry systems. In many, almost any motion will greatly diminish the system’s ability to extract a reliable heart rate. The artifact is most likely present due to normally non-pulsatile components of the body, such as …

    gvsu Repository record for Heart Rate Artifact Suppression (opens in a new tab)

  6. Scalable and Robust Inference of Sparse Brain Signals via Personalized Physiological System Identification

    … poor scalability, and there is the presence of motion artifacts. Therefore, firstly, we model the fast varying fluctuations, i.e., the phasic component of SC using a two-dimensional state-space model representing the diffusion and evaporation processes of sweating with a sparse impulsive signal …

    houston Repository record for Scalable and Robust Inference of Sparse Brain Signals via Personalized Physiological System Identification (opens in a new tab)

  7. Cardiac Fibrosis and Ventricular Arrhythmogenesis: Unravelling the influence of fibrosis on electrical dysfunction in the development of heart failure

    … scales, the SHR volumes displayed a marked reduction in fiber rotation in the sub epicardium. In addition, significant tissue connectivity reduction associated with fibrosis was also observed. Finally, electrical activation simulations demonstrated slowing in conduction velocity (CV) in the …

    auckland-ms Repository record for Cardiac Fibrosis and Ventricular Arrhythmogenesis: Unravelling the influence of fibrosis on electrical dysfunction in the development of heart failure (opens in a new tab)

  8. Enabling Robust Online Processing of Physiological Signals Corrupted by External Vibrations

    … SCG signals are highly susceptible to vibration artifacts, which limits their use in prehospital settings where accurate and timely responses are essential. A key goal of this dissertation is to enable SCG processing in noisy environments through robust denoising and feature extraction tools that …

    gatech Repository record for Enabling Robust Online Processing of Physiological Signals Corrupted by External Vibrations (opens in a new tab)

  9. Motion-resistant pulse oximetry

    … even when the wearer is under substantial motion are presented in this study.</p><p>The spectral components of the PPG waveform are known to appear at a fundamental frequency that corresponds to the participant's HR and at its harmonics. To match this signal, a time-varying comb filter …

    njit Repository record for Motion-resistant pulse oximetry (opens in a new tab)