  1. Dynamic Study of Flexible Sensors to Reduce Motion Artifacts

    … long-term heart rate trends or direct the motion of smart prosthetics. The capabilities are only as good as the signal quality. A significant challenge for these devices is that by their very definition – wearable – these flexible sensors suffer from motion artifacts not previously found …

    gatech Repository record for Dynamic Study of Flexible Sensors to Reduce Motion Artifacts (opens in a new tab)

  2. Modeling and Attenuation of Motion Artifacts in Capacitive ECG

    … biopotential measurements, they are prone to motion artifacts (MAs) because they do not stick to the patient's body. A MA is a large interference that can render the ExG analysis impossible. Often, it is much larger than the targeted signal and it can even saturate the analog front-end's …

    concordia Download PDF for Modeling and Attenuation of Motion Artifacts in Capacitive ECG (opens in a new tab)

  3. PPG Heart Rate Detection in the Presence of Motion Artifacts

    … a measured PPG signal predominantly suffers from motion artifacts. Ambient light conditions, temperature, and respiratory artifacts are a few other noise sources that affect the PPG signals when trying to measure heart rates. Most motion artifacts lie in the same frequency range as that of the …

    tamu Repository record for PPG Heart Rate Detection in the Presence of Motion Artifacts (opens in a new tab)

  4. A robust strategy for cleaning motion artifacts in resting state fMRI

    … of standard preprocessing of fMRI data is motion correction, as head motion during fMRI scanning can induce changes in blood oxygenation level dependent (BOLD) signals that may confound estimations of brain activity, particularly connectivity estimates between brain regions. In this thesis, …

    ubc Repository record for A robust strategy for cleaning motion artifacts in resting state fMRI (opens in a new tab) Download PDF for A robust strategy for cleaning motion artifacts in resting state fMRI (opens in a new tab)

  5. The Removal Of Motion Artifacts From Non-invasive Blood Pressure Measurements

    … These measurements are very sensitive to motion of the patient or the surroundings where the patient is. The slightest unexpected movements could offset the readings of the automatic Blood Pressure meter by a large amount or render the readings totally meaningless. Every effort must be …

    ucf Repository record for The Removal Of Motion Artifacts From Non-invasive Blood Pressure Measurements (opens in a new tab)

  6. PPGMotion: A Robust Algorithm for Identification of Motion Artifacts in Photoplethysmography Signals

    … the sensor measurements using PPG. Presence of motion artifacts in the signal decreases the accuracy of estimating the parameters and therefore reduces the reliabilty of these sensor devices. Motion artifacts can be both periodic or aperiodic. Existing state-of-the-art methods for motion …

    rice Repository record for PPGMotion: A Robust Algorithm for Identification of Motion Artifacts in Photoplethysmography Signals (opens in a new tab)

  7. REDUCTION OF SKIN STRETCH INDUCED MOTION ARTIFACTS IN ELECTROCARDIOGRAM MONITORING USING ADAPTIVE FILTERING

    … of CVD can be significantly impaired by motion artifacts which can cause misdiagnoses, inappropriate treatment decisions, and trigger false alarms. Skin stretch associated with patient motion is a main source of motion artifact in current ECG monitors. A promising approach to reduce …

    maryland Repository record for REDUCTION OF SKIN STRETCH INDUCED MOTION ARTIFACTS IN ELECTROCARDIOGRAM MONITORING USING ADAPTIVE FILTERING (opens in a new tab)

  8. Heart Rate and Heart Rate Variability Estimation in the Presence of Motion Artifacts

    … Dry electrodes could solve this problem, but the motion of the sensor relative to the skin affects measurements. Noncontact modalities (e.g. heart rate detected from a video of patient’s face) could offer further advancements in patient care, but again motion artifacts, caused by changing …

    carleton Repository record for Heart Rate and Heart Rate Variability Estimation in the Presence of Motion Artifacts (opens in a new tab)

  9. Improved noninvasive determination of blood pressure by oscillometry in the presence of motion artifacts

    … during clinical measurements in the presence of motion artifacts. A prototype system based on oscillometry that uses algorithms which take advantage of a multi-bladder cuff has the potential to improve measurements of blood pressure in noisy environments by detecting noise and rapidly estimating …

    ubc Repository record for Improved noninvasive determination of blood pressure by oscillometry in the presence of motion artifacts (opens in a new tab) Download PDF for Improved noninvasive determination of blood pressure by oscillometry in the presence of motion artifacts (opens in a new tab)

  10. Leveraging Meta-analytic Topic Maps to Identify and Remove Residual Motion Artifacts from fMRI Data

    Head motion during functional magnetic resonance imaging (fMRI) can seriously affect the integrity of the blood-oxygen-level-dependent (BOLD) signal and lead to biased or distorted inferences about neural responses to tasks or resting state. Most studies treat motion purely as a technical artifact …

    jhu Repository record for Leveraging Meta-analytic Topic Maps to Identify and Remove Residual Motion Artifacts from fMRI Data (opens in a new tab)

  11. Estimation of SpO2 levels and heart rate from ppg signals in the presence of motion artifacts

    … is curtailed by its vulnerability to motion-induced noise. Such noise can significantly distort the signal when the wearer moves, affecting the accuracy of essential health readings. This issue is particularly problematic in dynamic environments where movement is frequent, reducing the …

    njit Repository record for Estimation of SpO2 levels and heart rate from ppg signals in the presence of motion artifacts (opens in a new tab)

  12. Correction of Motion Artifacts in Whole Heart Optical Mapping Data Using Ratiometry and Image Processing Techniques

    … for normal and abnormal cardiac rhythm. However, motion artifacts contained in the optical action potentials (APs) represent a major drawback of the technique. The calculation of electrophysiological parameters of interest such as action potential duration (APD) is challenged by the presence of …

    calgary Repository record for Correction of Motion Artifacts in Whole Heart Optical Mapping Data Using Ratiometry and Image Processing Techniques (opens in a new tab)

  13. DEVELOPMENT OF A WEARABLE EEG SYSTEM FOR EVERYDAY USE: OVERCOMING MOTION ARTIFACTS, ELECTRODE POSITIONING, AND ON-DEVICE COMPUTING CHALLENGES

    … within a baseball cap, designed for use under motion. This flexible PCB-based device contains an embedded layer in the PCB to record motion artifact, enabling high signal-to-noise ratio (SNR) EEG sensing even while in motion. Steady-State Visually Evoked Potential (SSVEP) trials validated its …

    nus Repository record for DEVELOPMENT OF A WEARABLE EEG SYSTEM FOR EVERYDAY USE: OVERCOMING MOTION ARTIFACTS, ELECTRODE POSITIONING, AND ON-DEVICE COMPUTING CHALLENGES (opens in a new tab)

  14. Characterizing the Noise Associated with Sensor Placement and Motion Artifacts and Overcoming its Effects for Body-worn Physiological Sensors

    … noise are the sensor-skin contact interface and motion artifacts due to the user’s daily activities. These are challenging problems because the initial sensor placement by the user may not be ideal, the skin conditions can change over time, and the nature of motion artifacts is not predictable. …

    tamu Repository record for Characterizing the Noise Associated with Sensor Placement and Motion Artifacts and Overcoming its Effects for Body-worn Physiological Sensors (opens in a new tab)

  15. Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research

    … associated with contaminants, including motion artifacts. However, the limited availability of motion artifact data poses a challenge in developing and evaluating new tools (e.g., biases due to signal reuse). This research expands motion artifact data through two approaches. First, we …

    carleton Repository record for Motion Artifact Data to Facilitate Bioelectric Signal Quality Analysis Research (opens in a new tab)

  16. Tensor Decomposition for Motion Artifact Removal in Wireless ECG

    … noise source in mobile ECG is examined: Motion artifacts. We study the spectral characteristics of motion artifacts for a set of different motions representing everyday activities, namely: standing up, bending forward, walking, running, jumping, and climbing stairs. Furthermore, we …

    qucosa-diss

  17. Optimising combined angiographic, structural and perfusion imaging using arterial spin labelling MRI

    … ratio (SNR), and susceptibility to motion artifacts. This thesis focuses on addressing these limitations to enhance the quality and clinical utility of ASL-based combined imaging of blood vessels, brain structure, and tissue perfusion.</p> <p>Firstly, a novel, efficient two-stage …

    oxford Repository record for Optimising combined angiographic, structural and perfusion imaging using arterial spin labelling MRI (opens in a new tab)