Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"Motional Stark Effect"”

  1. Measurement of the Current Profile in Fusion Tokamaks using the Motional Stark Effect Diagnostic

    … in the core plasma are obtained using the motional Stark effect (MSE) diagnostic. This diagnostic measures polarised light emission from injected fast neutrals, to obtain the pitch angle of the magnetic field. These measurements are used as a constraint in plasma equilibrium solvers, from …

    durham Repository record for Measurement of the Current Profile in Fusion Tokamaks using the Motional Stark Effect Diagnostic (opens in a new tab)

  2. Geometric and Dynamic Phases in Rydberg State Interferometry

    … using circular Rydberg states. Dispersive effects fundamentally limited this approach. Future experiments aimed at overcoming this dispersion could allow for a full-loop interferometer that could be sensitive to inertial effects. This inspired an experiment where the phase due to the …

    ucl Repository record for Geometric and Dynamic Phases in Rydberg State Interferometry (opens in a new tab)

  3. Q-profile reconstruction during the current ramp at TEXTOR for current diffusion measurements, assessment of methods and measurements

    … equilibrium from limited input data-Spectral Motional Stark Effect (MSE) measurements, whereby beam emission spectra of injected hydrogen molecules are related to the magnetic field at the point of emissionBoth methods were found to yield unreliable results on the q-profile. Further analysis …

    eindhoven Repository record for Q-profile reconstruction during the current ramp at TEXTOR for current diffusion measurements, assessment of methods and measurements (opens in a new tab)

  4. Current profile measurements using MSE on Alcator C-Mod

    A Motional Stark Effect (MSE) diagnostic system has been installed on the Alcator C-Mod tokamak to measure the plasma internal magnetic pitch angle profile. The diagnostic utilizes polarization patterns from Doppler-shifted Balmer-alpha decay emission from an energetic neutral beam injected into a …

    mit Repository record for Current profile measurements using MSE on Alcator C-Mod (opens in a new tab)

  5. Generation and analysis of plasmas with centrally reduced helicity in full-tungsten ASDEX Upgrade

    … Messungen einer Schlüsseldiagnostik, die auf dem Motional Stark Effect aufbaut, bewerkstelligt. Während dieser Arbeit wurde entdeckt, dass die Diagnostik durch polarisiertes Hintergrundlicht gestört wird. Ein Prototyp zur Korrektur wurde erfolgreich getestet. Außerdem wurden Nichtlinearitäten im …

    lmu-germany Repository record for Generation and analysis of plasmas with centrally reduced helicity in full-tungsten ASDEX Upgrade (opens in a new tab)

  6. Impact of wave-filament scattering in the scrape-off layer during lower hybrid current drive

    … and retains all single-filament full-wave effects while remaining computationally inexpensive. Notably, it is found that LH waves can asymmetrically scatter in wave-number phase-space due to full-wave interactions with spatially coherent density fluctuations. Coupling to GENRAY/CQL3D …

    mit Repository record for Impact of wave-filament scattering in the scrape-off layer during lower hybrid current drive (opens in a new tab)

  7. Performance assessment of the KSTAR MSE diagnostic

    … profile, j. To measure and to control j, a Motional Stark Effect (MSE) diagnostic is in development at KSTAR. Such a diagnostic measures locally the magnetic pitch angle, giving the unknown poloidal magnetic field. This thesis investigates the ability of this diagnostic to distinguish the …

    eindhoven Repository record for Performance assessment of the KSTAR MSE diagnostic (opens in a new tab)

  8. Polarisation Coherence Imaging of Electric and Magnetic Fields in Plasmas

    … inside high temperature fusion plasmas. The motional Stark effect (MSE) is the principal application for the technique, involving measurement of the Balmer-α polarised emission from high velocity neutral beam atoms subjected to a strong vxB electric field. The research in this thesis examines …

    anu Repository record for Polarisation Coherence Imaging of Electric and Magnetic Fields in Plasmas (opens in a new tab)

  9. Towards the formation of a forward-boosted beam of neutral antihydrogen for gravitational studies

    … the magnetic field, since it is bounded by the motional Stark effect induced field ionisation (nmax ∝ B−1/4) [14]. Therefore, a lower magnetic field in the formation region can enhance greatly the production rate of antihydrogen. To the main vacuum chamber, the positrons line is connected, which …

    trento Repository record for Towards the formation of a forward-boosted beam of neutral antihydrogen for gravitational studies (opens in a new tab)