Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Motor cooling"”.

  1. The Dynamics of Fluid–Solid Interactions and Its Implications for Enhanced Motor Cooling

    … systems through active single/two phase cooling, along with the exploration of thermal energy storage modules and innovative thermally conductive insulation material. We propose a hybrid cooling approach, and both experimental and modeling results demonstrate the effectiveness of this …

    tamu Repository record for The Dynamics of Fluid–Solid Interactions and Its Implications for Enhanced Motor Cooling (opens in a new tab) Embargoed until 2028-05-01

  2. Technologies for ice protection of aircraft air intakes. Development of an electric propulsion motor cooling inlet ice protection system using CFD, droplet impingement and thermal modelling

    … exhaust gases are not output from the electric motors. The main objective of this study is to investigate ice protection technologies for electric propulsion motor air intakes to ensure safe end energy-efficient flight without any icing hazards. A generic model of a submerged cooling air intake …

    chalmers Repository record for Technologies for ice protection of aircraft air intakes. Development of an electric propulsion motor cooling inlet ice protection system using CFD, droplet impingement and thermal modelling (opens in a new tab)

  3. Enhancing geothermal heat pump systems with parametric performance analyses

    … geothermal heat pump, a heat pump cycle with motor cooling/refrigerant preheating, and a heat pump cycle utilizing an economizer with respect to first law is conducted through simulation. Changing compressor, pump, and motor efficiency, along with condenser pressure, evaporator pressure, …

    uoit Repository record for Enhancing geothermal heat pump systems with parametric performance analyses (opens in a new tab)

  4. The techno-economical impact of reducing chilled water usage on a deep level gold mine

    … water usage at the underground dewatering pump motor coolers, as a significant amount of chilled water is consumed for cooling purposes. This study proposes alternative methods of cooling and discuss the physical implementation thereof. The three chilled water reduction strategies investigated …

    nwu-za Repository record for The techno-economical impact of reducing chilled water usage on a deep level gold mine (opens in a new tab)

  5. Nitrogen Commissioning of a Subsea Compression Station. An investigation of how process equipment intended for natural gas is affected by operating with nitrogen

    … with regards to compressor performance, cooling etc. Incorrect operation with N2 might cause catastrophic damage of equipment. This work, carried out in cooperation with Aker Solutions, aims to investigate the effects of nitrogen on the operation of a subsea compression station. Specific …

    chalmers Repository record for Nitrogen Commissioning of a Subsea Compression Station. An investigation of how process equipment intended for natural gas is affected by operating with nitrogen (opens in a new tab)

  6. Multiscale analysis and validation of a novel in-slot heat exchanger for motor thermal management

    … seeks higher power densities in electric vehicle motors, there is a need for superior thermal management solutions to maintain optimal motor system temperatures. Prior simulation and experimental work on motor cooling has identified the copper windings in the stator and the end-windings outside …

    gatech Repository record for Multiscale analysis and validation of a novel in-slot heat exchanger for motor thermal management (opens in a new tab)

  7. Design of a High-Speed, High-Power Density Permanent Magnet Synchronous Motor for Electric Vehicle Traction

    A high-speed electric motor is developed as part of a high-density traction system that includes the motor and the power electronics stage. To consider the close interdependence of the inverter and the motor sizing for a specific application, the high-level design of the high-density system and the …

    concordia Download PDF for Design of a High-Speed, High-Power Density Permanent Magnet Synchronous Motor for Electric Vehicle Traction (opens in a new tab)

  8. Design, Modeling and Control of a Thermal Management System for Hybrid Electric Vehicles

    … of a lithium battery pack and electric motors, HEVs offer a significantly higher fuel efficiency than traditional vehicles that are driven solely by an internal combustion engine. However, the additional HEV components also introduce new challenges for the powertrain thermal management …

    clemson Repository record for Design, Modeling and Control of a Thermal Management System for Hybrid Electric Vehicles (opens in a new tab)

  9. A windows-based application for predicting automobile engine heat rejection requirements

    … rates quickly and efficiency provides automotive cooling system engineers the flexibility to alter designs without the time and costs of laboratory experimentation. The purpose of this research is to develop an analytical tool that predicts engine heat rejection to coolant rates using a …

    ttu Repository record for A windows-based application for predicting automobile engine heat rejection requirements (opens in a new tab)

  10. Increasing Electric Machine Power Density With a New End-winding Cooling System

    … is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. For high performance electric motors, water-jacket cooling systems are usually used to remove heat coming from the windings and the laminations. However, …

    gatech Repository record for Increasing Electric Machine Power Density With a New End-winding Cooling System (opens in a new tab)

  11. Chladící systém Formule Student

    … část obsahuje výpočty ztrát měniče a elektromotorů. Jsou navrženy parametry výměníků a sestaven chladicí okruh. Požadavkem je nepřekročení provozních teplot v průběhu závodních jízd monopostu. Získáním přesnějších vstupů do výpočtů je dosaženo optimálních parametrů navrhovaných komponentů.

    brno-tech Repository record for Chladící systém Formule Student (opens in a new tab)

  12. Návrh chlazení elektrických strojů pro výrobní stroje a systémy

    … je návrh vodního chlazení malého synchronního motoru s výkonem do 10kW. Tepelné ztráty motoru byly vypočítány analyticky. Následně byly v Ansysu vytvořeny tepelné modely motoru pro výchozí vodní chlazení a pro dva nové návrhy. Společné okrajové podmínky byly definovány z analytického výpočtu. …

    brno-tech Repository record for Návrh chlazení elektrických strojů pro výrobní stroje a systémy (opens in a new tab)

  13. Systémy chlazení elektromotorů v pohonech elektrických vozidel

    … a možnosti jejich účinného chlazení v elektromotorech používaných v pohonech elektrických vozidel. V práci jsou rozebrány různé druhy ztrát vznikající v elektrických strojích, které vedou k nežádoucímu ohřevu, a to jak z hlediska elektrických, tak mechanických procesů. Dále jsou představeny …

    brno-tech Repository record for Systémy chlazení elektromotorů v pohonech elektrických vozidel (opens in a new tab)

  14. Optimalizace chladicího systému asynchronního stroje

    … analýzu konkrétního třífázového asynchronního motoru s kotvou nakrátko a optimalizaci jeho chlazení.

    brno-tech Repository record for Optimalizace chladicího systému asynchronního stroje (opens in a new tab)

  15. The Importance of Electric Motor Thermal Management and the Role of Polymer Composites in Axial Cooling

    … research investigates the effect that axial cooling channels will have on the performance of the thermal management system of a hypothetical switched reluctance motor. A baseline motor with no axial cooling will be compared to an identical motor with the innovative cooling design implemented. …

    mcmaster Repository record for The Importance of Electric Motor Thermal Management and the Role of Polymer Composites in Axial Cooling (opens in a new tab)