Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 15 of 15 for “"Multi-channel EEG"”
-
MULTI-CHANNEL EEG SENSOR FRONTEND FOR PORTABLEHEALTH CONDITION MONITORING APPLICATIONS
… converter (ADC) for Electroencephalography (EEG) sensor frontend. The first amplifier is a low power capacitive-coupled instrumentation amplifier (CCIA) which achieves a power consumption of 540nW. This amplifier is capable of cancelling a rail to rail electrode offset, where a high input …
-
Avian sleep
… explores both aspects in zebra finches using multi-channel EEG and LFP recordings. First, we show that sleep patterns change with age: juveniles spend more time in intermediate sleep (IS), especially males engaged in vocal learning, while adults exhibit more SWS and REM sleep. Functional …
-
Energy-efficient digital design of reliable, low-throughput wireless biomedical systems
… The power consumed in conventional wireless EEG (biomedical) systems is dominated by digital microcontroller and the radio frequency (RF) transceiver. To reduce the power associated with the digital processor, data compression can reduce the volume of data transmitted. An adaptive data …
-
Patient-specific seizure onset detection
… the onset of epileptic seizures in non-invasive EEG, and then initiate time-sensitive clinical procedures like ictal SPECT. We adopt a patient-specific approach because of the clinically observed consistency of seizure and non-seizure EEG characteristics within patients, and their great …
-
Multichannel EEG Signal Classification -A Geometric Approach
… sleep stages of a patient using his/her recorded EEG signals falls in the area of signal classification. In general, this involves extracting from the EEG signals, a signal feature on which the classification is performed. In this thesis, we apply the techniques of signal classification to the …
-
EEG signatures of psychiatric and mental illness
… MMN and to examine the suitability of a single channel dry-electrode device as a substitute for the normal laboratory based procedure of conducting electroencephalography (EEG). This approach is being considered due to the difficulty of performing lengthy and uncomfortable multi-channel EEG on …
-
Early biomarkers to predict grade of encephalopathy following hypoxic ischaemic injury
… neurological examination, and early continuous multi-channel EEG. Cord samples from a control cohort of healthy infants were used for comparison. Biomarkers studied included; multiple inflammatory proteins using multiplex assay; the metabolomics profile using LC/MS; and the miRNA profile using …
-
ANALYSIS OF ELECTRICAL AND MAGNETIC BIO-SIGNALS ASSOCIATED WITH MOTOR PERFORMANCE AND FATIGUE
… research related to human bio-signals (EEG, MEG, EMG and fMRI) acquired during repetitive maximal voluntary contractions (MVC) that induced severe fatigue. Fatigue is a common experience that reduces productivity and quality of life and increases chances of injury. Although abundant …
-
Eine Methode zur nichtinvasiven EEG-Ableitung am wachen, stehenden Pferd
The technical development towards digital multi-channel EEG-devices is combined with advantages in data reproduction and display compared with paper- writing EEG-devices. This opens new possibilities of EEG registration and evaluation. Therefore the possibility of a non-invasive …
-
Statistical Inference on Time Series of Graphs
… recently there has been increased interest in multiple graphs concerning modeling and performing statistical inference. Among recent developments in statistical inference on multiple networks, MASE is a statistically principled multiple random graph embedding method for networks with latent …
-
Classification of Electroencephalogram in Ovine Model of Perinatal Hypoxia by Movement of the Autoregressive Model Parameters
… e.g., conventional electroencephalogram (EEG) that non-invasively measures the electrical activity of the brain from the scalp. Full multi-channel EEG with at least nine and a maximum of 40 electrodes on the scalp and face takes at least 60 minutes of careful handling by trained personnel. …
-
Deep Learning Architectures for Enhanced Emotion Recognition from EEG and Facial Expressions
… domain information from Electroencephalogram (EEG) signals. The model is a cascade of deep learning networks consisting of a pre-trained convolutional neural network (CNN) and residual blocks of recurrent networks. The former extracts spatial features from the signal while the latter learns the …
-
Patient-Specific Epileptic Seizure Onset Detection via Fused Eeg and Ecg Signals
… the fusion of independent electroencephalogram (EEG) and electrocardiogram (ECG) based decisions. The EEG-based detector relies on a on a common spatial pattern (CSP)-based feature enhancement stage that enables better discrimination between seizure and non-seizure features. The EEG-based …
-
Neonatal seizure detection: a deep learning approach
… in infants are underreported; specialist EEG monitoring equipment and neonatal neurophysiological expertise are required to reliably detect neonatal seizures due to the predominance of sub-clinical seizure events. Often, the required level of clinical expertise is not available …
-
An in-depth characterisation of neonatal seizures by early continuous video-EEG analysis
… dissociation (ECD) of seizures. Methods The multichannel video-EEG was used in this research study as the gold standard to detect seizures, allowing accurate quantification of seizure burden to be ascertained in term neonates. The entire EEG recording for each neonate was independently …