Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"Multi-contact"”.

  1. Case studies in multi-contact locomotion

    … a robot's center of mass (CoM) behavior based on contact constraints, and any arbitrary CoM path for situations in which the system has single or multiple points of contact through which external reaction forces may be applied. Our method consists of first leveraging previous work on multi-contact …

    texas Repository record for Case studies in multi-contact locomotion (opens in a new tab)

  2. Control strategies for series elastic, multi-contact robots

    As robots designed for physical interaction with humans---humanoids, exoskeletons and beyond---make their entrance into society, understanding the limitations of their interaction behavior will be key to their effective use. The state of the art method for allowing such systems to be both compliant …

    texas Repository record for Control strategies for series elastic, multi-contact robots (opens in a new tab)

  3. Humanoid Robot Friction Estimation in Multi-Contact Scenarios

    … the friction constraints at the hands during multi-contact poses without the addition of hardware to the platform. This is achieved by utilizing disturbance detection as a method of monitoring active forces at a single external point and deriving available friction force at said contact point …

    vt Repository record for Humanoid Robot Friction Estimation in Multi-Contact Scenarios (opens in a new tab)

  4. CONTROL OF MULTI-CONTACT SYSTEMS VIA LOCAL HYBRID MODELS

    … and locomotion, robots need to make and break contact with their environment. Although such multi-contact systems are common, they pose a significant challenge when it comes to analysis and control. This difficulty primarily stems from two key factors: 1) the rapid increase in the number of …

    penn Repository record for CONTROL OF MULTI-CONTACT SYSTEMS VIA LOCAL HYBRID MODELS (opens in a new tab)

  5. Optimization-based multi-contact motion planning for legged robots

    … endow robots with capabilities to reason about contacts but this vital skill is currently missing. An important justification for this is that contact phenomena are inherently non-smooth and non-convex. As a result, posing and solving problems involving contacts is non-trivial. …

    greece Repository record for Optimization-based multi-contact motion planning for legged robots (opens in a new tab)

  6. Whole-body trajectory generation and control strategies for multi-contact robots

    … use of nonlinear dynamics, complex constraints, multiple contacts, disturbances, and uncertainties. These are fundamental requirements needed to advance the use of general purpose robots dynamically interacting in a wider variety of environments. Therefore, this thesis addresses challenges that …

    texas Repository record for Whole-body trajectory generation and control strategies for multi-contact robots (opens in a new tab)

  7. Multi-contact Stability of Multi-Legged Robots Operating in Unstructured Spaces

    … in this research is to develop an effective multi-contact locomotion system for multi-legged robots enabling them to operate in unstructured spaces. The solution allows humanoids to use not only their feet but also any other parts of their body to contact the environment and enhance their …

    calgary Repository record for Multi-contact Stability of Multi-Legged Robots Operating in Unstructured Spaces (opens in a new tab)

  8. Phase space planning for robust locomotion

    … Phase Plane trajectories are predicted based on multi-contact and inverted pendulum dynamics. To deal with the nonlinear dynamics of the contact motions and their dimensionality, we plan a geometric surface of motion beforehand and rely on numerical integration to solve the models. In particular, …

    texas Repository record for Phase space planning for robust locomotion (opens in a new tab)

  9. Discrimination of Neural Sources using Spatiotemporal Signatures in Nerve Cuff Electrode Recordings

    … the recording selectivity achievable using multi-contact nerve cuff electrodes. Neural activity recorded from multi-contact nerve cuffs for a given neural pathway will have a distinct spatiotemporal signature. This signature is determined by the location of the bioelectric sources in the …

    toronto-retro Repository record for Discrimination of Neural Sources using Spatiotemporal Signatures in Nerve Cuff Electrode Recordings (opens in a new tab)

  10. Evaluation of the effect of contact between risers and guide frames on offshore spar platform motions

    … risers in waves, winds, and currents. The new multi-contact analysis program is developed for the nonlinear multi-contact coupling between vertical risers and guide frames inside of the spar moon-pool. The program extends capability of the current coupled dynamic analysis program, WINPOST, by …

    tamu Repository record for Evaluation of the effect of contact between risers and guide frames on offshore spar platform motions (opens in a new tab)

  11. An experimental and numerical investigation of compositional displacements in heterogeneous reservoirs

    … media occur when there is mass transfer between multiple fluids. A good example of such flows is gas injection to an oil reservoir for enhanced oil recovery. Injected gas can be miscible with oil at first contact or at multiple contacts or can stay nearly immiscible with oil. This depends on how …

    unsw Repository record for An experimental and numerical investigation of compositional displacements in heterogeneous reservoirs (opens in a new tab)

  12. Integrated Radio Frequency Isolator

    … bandwidth from DC to 1127 MHz. A technique using multi-contact Hall plates is shown to reduce isolator insertion loss to 0.89 dB, which is competitive with ferrite-based devices.

    calgary Repository record for Integrated Radio Frequency Isolator (opens in a new tab)

  13. Toward a wirelessly-powered, fascicle-specific system for peripheral nerve stimulation

    … current at the nerve trunk, often activating multiple fascicles simultaneously and limiting fine motor control. To address this, research has advanced toward fascicle-specific stimulation, selectively recruiting individual fascicles within a mixed nerve to restore more natural, coordinated …

    rice Repository record for Toward a wirelessly-powered, fascicle-specific system for peripheral nerve stimulation (opens in a new tab) Embargoed until 2027-08-01

  14. Stimulation and Recording Interfaces for Data Transmission to and from a Micro Neural Stimulation Device

    … galvanic impulse communication with an epineural multi-contact nerve cuff. This design facilitates high-throughput, low-power stimulation, recording, and data transfer. Development efforts include optimizing neural stimulation protocols, validating deep tissue galvanic transmission, and …

    boise Repository record for Stimulation and Recording Interfaces for Data Transmission to and from a Micro Neural Stimulation Device (opens in a new tab)

  15. Investigation of Slow Release Relays Using Reed Switches

    … introduced to ensure that rapid closure of the contacts is possible, on the application of excitation. To this end, a second winding, in addition to the operating coil, is included in the relay, and the reed switches are located in the leakage field between these windings. This is the …

    aston Repository record for Investigation of Slow Release Relays Using Reed Switches (opens in a new tab) Download PDF for Investigation of Slow Release Relays Using Reed Switches (opens in a new tab)

  16. Methane Infusion Improved Oil Recovery In The Bakken Formation

    … for unconventional reservoirs. Integrated multi-scale investigations included quantum molecular theory, nanoscale characterization, NMR experimentation, and field scale reservoir simulation. FEG-SEM analysis of core samples enabled development of a peer-reviewed pore size classification …

    nodak Repository record for Methane Infusion Improved Oil Recovery In The Bakken Formation (opens in a new tab)

  17. From bipedal locomotion to prosthetic walking: A hybrid system and nonlinear control approach

    … AMBER2, resulting in a sustainable and robust multi-contact walking gait. As one of the ultimate goals of studying human-like robotic locomotion, the proposed systematic methodology is then translated to achieve prosthetic walking that is both human-like and energy-efficient, with reduced need …

    gatech Repository record for From bipedal locomotion to prosthetic walking: A hybrid system and nonlinear control approach (opens in a new tab)

  18. Nonlinear finite element analysis of sheet pile interlocks

    … the interlock of a sheet pile will provide three contact points for connection with another sheet pile. The problem is highly nonlinear in nature which involves large deflections and rotations, elastic-plastic material response, and a nonlinear boundary effect due to multi-contact surfaces. The …

    vt Repository record for Nonlinear finite element analysis of sheet pile interlocks (opens in a new tab)

  19. Modeling and characterization of photoresponse of nanowires with asymmetric contacts and bending strain

    This work investigates (i) contact asymmetry induced response of semiconductors, with emphasis on nanowire photo response, and (ii) strain induced electronic and optoelectronic properties of narrow silicon nanowires. Contact area asymmetry is shown to produce large zero-bias photo response in bulk …

    washington Repository record for Modeling and characterization of photoresponse of nanowires with asymmetric contacts and bending strain (opens in a new tab)

Page 1 of 2