Results 1 to 20 of 78 for “"Multi-contrast"”
-
Multi-contrast Photoacoustic Microscopy
… moderate imaging depth, excellent imaging contrast and functional imaging capability. Taking full advantage of this powerful weapon, we have investigated different anatomical, functional, flow dynamic and metabolic parameter measurements using photoacoustic microscopy. Specifically, …
-
Self-supervised multi-contrast MRI denoising
… in medical diagnostics, offering essential multi-contrast imaging capabilities. However, MRI quality is often compromised by inherent noise, which can hinder both image clarity and analytical accuracy. This thesis presents the "Corruption2Self" (C2S) framework, a self-supervised method for …
-
Synthesis-Based Harmonization of Multi-Contrast Structural MRI
… disorders of the central nervous system such as multiple sclerosis (MS). The flexible design of the MRI system allows for the collection of multiple images with different acquisition parameters in a single scanning session. This flexibility also poses challenges when pooling data collected on …
-
Multimodal Optical Microscopy Systems for Multi-Contrast Tissue Imaging
… microscopic resolution and a wide range of contrasts. In particular, photoacoustic imaging harnesses the combined advantages of ultrasound and optical contrast to resolve label-free absorption from endogenous molecules including hemoglobin and nucleic acids. While this has conventionally …
-
Compressive sensing methods for multi-contrast magnetic resonance imaging
… first, an optimization framework for single contrast CS MRI is presented. The method relies on an augmented Lagrangian based method, specifically alternating direction method of multipliers (ADMM). The ADMM framework is used to solve a constrained optimization problem with an objective …
-
Multi-contrast magnetic resonance imaging with deep generative learning
… images with excellent soft tissue contrast across various anatomies of interest. Despite its superior resolution and versatile contrast options, MRI is inherently a slow imaging technique due to the sequential nature of data acquisition. This dissertation investigates two distinct …
-
MULTI-CONTRAST OPTICAL COHERENCE TOMOGRAPHY FOR VARIOUS BIOMEDICAL APPLICATIONS
… In this dissertation, we developed and applied multi-contrast OCT systems for early cancer detection, anticancer therapy monitoring, human organ transplantation viability evaluation, and aging vascular characterization. In Chapter 1, I introduce the principle and development of the OCT system. I …
-
Multi-contrast optical coherence tomography for brain imaging and mapping
… coverage. This dissertation develops a novel multi-contrast optical coherence tomography (MC-OCT) technique for the application of brainwide imaging and architectural mapping in 3D at high spatiotemporal resolution, with an emphasis on the connective tracts. The image contrasts originate from …
-
Technical Development of Accelerated and Multi-contrast Echo-planar Imaging
… echo spacing. To overcome these limitations, multi-shot and parallel MRI schemes can be employed, and multi-band/simultaneous multi-slice techniques can be used to further improve temporal resolution. However, all these EPI schemes are vulnerable to Nyquist artifact, which reduces …
-
Multi contrast, multi illumination and microwave imaging of 2D inhomogeneous scatterers
… is used as an investigation domain. Unrelated multi sources are used to illuminate the scatterer at different angles for reconstructing the less erroneous complex permittivity profile. Multi-frequency effect with the noise is addressed during the reconstruction of the complex permittivity …
-
Deep learning-based medical image reconstruction for multi-contrast magnetic resonance imaging
… leveraging highly correlated information across contrasts in sequentially acquired multi-contrast MR scans. We design a framework to optimise the under-sampling pattern of a target MRI contrast, by exploiting the com- plementary fully-sampled reference contrast through a novel synthesis-based …
-
Hartmann-based wavefront sensing and multi-contrast imaging with synchrotron and laboratory sources
… Hartmann-Maske für die optische Messtechnik, die Multikontrastabbildung und die Computertomographie gezeigt. Mit dem Shack-Hartmann-Wellenfrontsensor wurde eine Multikontrastabbildung der röntgenrefraktiven Diamantlinse durchgeführt. Es war möglich, neben der Intensität auch differentielle …
-
DEVELOPEMENT OF WIDEFIELD MULTI-CONTRAST OPTICAL METHODS FOR IN VIVO MICROVASCULAR SCALE IMAGING
… in vivo optical imaging methods rely on a single contrast mechanism, thereby limiting one’s ability to characterize more than one biological variable. However, most biological systems are complex and are comprised of multiple variables. Therefore, optical methods that employ multiple contrast …
-
Toward advances in data acquisition and analysis for quantitative multi-contrast magnetic resonance imaging
… noninvasive imaging tool with superior tissue contrast and greater specificity for disease than other imaging modalities; however, MRI is costly and lengthy, making it difficult to deploy quantitative imaging techniques alongside existing clinical protocols. Moreover, radiologists require high …
-
Sensitivity Analysis and Multi Contrast Imaging of Magnetic Resonance Magnetohydrodynamic Flow Velocimetry at 3 Tesla
… acquisition and reconstruction techniques for multi-contrast imaging that contains MHD flow velocity imaging. As the result of the MR experiments conducted with a cylindrical phantom, it is determined that the magnitude of the MHD flow velocity distribution inside a homogeneous medium is …
-
One VAE to Squeeze Them All: Causality-Aware Spatiotemporal Compression for Multi-Contrast MRI Latent Unification
… decision-making by enabling tasks such as multi-modal contrast prediction, longitudinal tracking, and lesion characterization. In clinical practice, acquiring all MRI contrasts for each patient is often impractical due to time, cost, and patient burden, making the prediction of missing …
-
Development of a multi-contrast small animal retinal imaging system for the investigation of retinal degenerative diseases
… extensions of OCT allowed the generation of multiple contrasts providing information-rich images. This thesis focuses on the development and verification of a polarization-diversity OCT (PD-OCT) system tailored for the mouse retina to acquire high-resolution multi-contrast images. The …
-
Diffusion tensor magnetic resonance electrical impedance tomography (DT-MREIT) and its expansion to multi-physics multi-contrast magnetic resonance imaging
… namely the injected current nonlinear encoding -multi-echo–FLASH (ICNE-ME-FLASH), is implemented for MRCDI to acquire qualified (high SNR) Bz and J distributions in a clinically acceptable scan time. Also, an analysis is developed to investigate the combined effect of relevant sequence parameters …