Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 8 of 8 for “"Multifocal electroretinography"”.

  1. Sensitivity and Specificity of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity

    To calculate the sensitivity and specificity of multifocal electroretinography (mfERG) in detection of chloroquine and hydroxychloroquine retinal toxicity, 120 eyes of 63 patients were evaluated using the currently recommended diagnostic tests. The results were compared to those of 54 eyes of 28 …

    ottawa-retro Repository record for Sensitivity and Specificity of Multifocal Electroretinography in Detecting Chloroquine and Hydroxychloroquine Retinal Toxicity (opens in a new tab)

  2. Αντιμετώπιση του οιδήματος της ωχράς κηλίδας που οφείλεται σε θρόμβωση φλέβας αμφιβληστροειδούς με ενδοϋαλοειδική ένεση αντιVEGF παράγοντα

    … acuity, central retinal thickness (CRT) and multifocal electroretinography (mfERG) responses changes at baseline, one month after the third injection and at the end of the two year long follow up period.Results: Patients with CRVO had mean best-corrected Snellen visual acuity of 0.10 at …

    greece Repository record for Αντιμετώπιση του οιδήματος της ωχράς κηλίδας που οφείλεται σε θρόμβωση φλέβας αμφιβληστροειδούς με ενδοϋαλοειδική ένεση αντιVEGF παράγοντα (opens in a new tab)

  3. Paveldimų tinklainės distrofijų klinikinių ir genetinių charakteristikų vertinimas /

    … into clinical practice, and one of them, multifocal electroretinography, was applied in Lithuania for the first time. This study was the first research conducted in Lithuania allowing identify, analyze, group, perform genetical testing and assess genotype-phenotype correlations of IRD.

    vilnius Repository record for Paveldimų tinklainės distrofijų klinikinių ir genetinių charakteristikų vertinimas / (opens in a new tab)

  4. Evaluation of clinical and genetic characteristics of the inherited retinal dystrophies /

    … into clinical practice, and one of them, multifocal electroretinography, was applied in Lithuania for the first time. This study was the first research conducted in Lithuania allowing identify, analyze, group, perform genetical testing and assess genotype-phenotype correlations of IRD.

    vilnius Repository record for Evaluation of clinical and genetic characteristics of the inherited retinal dystrophies / (opens in a new tab)

  5. M-Sequences Related to the Multifocal Electroretinogram: Identification of Appropriate Primitive Polynomials to Avoid Cross-Contamination in Multifocal Electroretinogram Responses

    The basis of multifocal ERG is the use of a decimated m-sequence for simultaneous and independent stimulation of many areas of the visual pathway. The purpose of this thesis is to investigate the effects of cross contamination from higher orders of the response. To examine the effects of cross …

    glasgow Download PDF for M-Sequences Related to the Multifocal Electroretinogram: Identification of Appropriate Primitive Polynomials to Avoid Cross-Contamination in Multifocal Electroretinogram Responses (opens in a new tab)

  6. Ηλεκτροφυσιολογική μελέτη οφθαλμών σε ασθενείς με βήτα μεσογειακή αναιμία

    … underwent ophthalmoscopy, full-field electroretinography (ERG), visual evoked potentials (VEP), multifocal electroretinography (mfERG), fundus autofluorescence (FAF) imaging and optical coherence tomography (OCT) scans. Results: Retinal pigment epithelium changes were present in two …

    greece Repository record for Ηλεκτροφυσιολογική μελέτη οφθαλμών σε ασθενείς με βήτα μεσογειακή αναιμία (opens in a new tab)

  7. Experimental porcine models of retinal ischemia

    … were analysed using indirect ophthalmoscopy, multifocal ERG with fundus imaging, fluorescence angiography and conventional angiography. The porcine model of pressure-induced retinal ischaemia resulted in multifocal ERG changes typical of retinal ischaemia although there may be a confounding …

    lund Repository record for Experimental porcine models of retinal ischemia (opens in a new tab) Download PDF for Experimental porcine models of retinal ischemia (opens in a new tab)