Investigations into static multileaf collimator based intensity modulated radiotherapy
… IMRT is commonly achieved through the use of a multileaf collimator (MLC). One of the hindrances at present to the widespread use of IMRT is the increased time required for its planning, delivery and verification. In this thesis one particular method of MLC based IMRT, known as Static Multileaf …
-
A dual assembly multileaf collimator for radiotherapy / Peter Brian Greer.
A multileaf collimator for radiation therapy has been designed that splits each leaf bank into two vertically displaced assemblies or levels with each level consisting of alternate leaves and leaf spaces. The radiation profiles transmitted for image formation through the collimator design were …
-
Intensity modulation of therapeutic photon beams using a rotating multileaf collimator
… available methods. Through improvements in multileaf collimator (MLC) based fluence generation, a dose distribution may be generated that conforms more closely to the tumour target volume. Healthy tissue surrounding the target volume will therefore receive less dose, reducing the probability …
-
A compact multileaf collimator for conventional and intensity modulated fast neutron therapy
A 120 leaf collimator of high resolution has been constructed to shape a fast neutron therapy (FNT) beam produced from a superconducting cyclotron using the d(48.5) + Be reaction. The computer controlled multileaf collimator (MLC) replaces an aging, manually operated multirod collimator (MRC). The …
-
Monte Carlo modeling of the Millennium 120-leaf multiLeaf collimator for 3D-CRT, IMRT and VMAT calculations
… η πλήρης μοντελοποίηση του Millennium 120-leaf Multileaf Collimator (MLC) χρησιμοποιώντας μεθό- δους προσομοίωσης Monte Carlo (MC). Απώτερος στόχος είναι να διερευνηθεί αν η μοντελοποίηση του MLC μπορεί να χρησιμοποιηθεί για την εξατομικευμένη επιβεβαίωση του πλάνου θεραπείας. Αρχικά, με την …
-
Half-Field Volumetric Modulated Arc Therapy for Multileaf Collimator Leakage Reduction and Dosimetric Impact in Large Irradiated Field
… spare organ at risk (OAR), doses using multileaf collimator’s optimal segments and volumetric modulated arc therapy (VMAT) using a half-beam technique (HF) were implemented for WPRT. METHODS AND MATERIALS: Dosimetric benefits of HF-VMAT were presented with dose conformity and dose volume …
-
DEVELOPMENT AND INVESTIGATION OF INTENSITY-MODULATED RADIATION THERAPY TREATMENT PLANNING FOR FOUR-DIMENSIONAL ANATOMY
… motion, tumor tracking using a dynamic multileaf collimator delivery technique was chosen as a promising method. A formalism to solve a general four-dimensional intensity-modulated radiation therapy treatment-planning problem was developed. Specific solutions to this problem accounting …
-
The Effect of Plan Modulation on Dosimetric Effects due to Interplay in Hypofractionated Volumetric Modulated Arc Therapy Liver Radiotherapy Treatments
… (VMAT), the interplay between tumour motion and multileaf collimator (MLC) leaf motions may cause differences between the planned and delivered dose distributions. These interplay effects may cause underdosage in the tumour, potentially reducing treatment efficacy. This uncertainty has led to …
-
Modelagem computacional de um acelerador linear e da sala de radioterapia para cálculo da dose efetiva em pacientes submetidos a tratamento de câncer de próstata
… equipped with a highly detailed VARIAN HD120 multileaf collimator. Validation was achieved by comparing calculated percentage dose depths and lateral dose profiles with commissioning measurements (golden data) from the manufacturer. The 4 x 4 cm2 , 10 x 10 cm2 and 20 x 20 cm2 fields were …
-
Monte Carlo Studies in the Applications of Magnetic Fields to Electron Radiotherapy
… approach involves placing a fixed metal collimator near the patient’s skin to block scattered radiation, providing a static treatment. This study explores the dosimetric impact of magnetic fields on therapeutic electron beams and the potential application of magnetic fields in modulated …
-
Resolution Adaptation and Secondary Optimization of Volumetric Modulated Arc Therapy
… and radio-sensitive organs. The multi-leaf collimator (MLC), an electro-mechanically controlled shielding device composed of thin tungsten leaves, allows VMAT to be delivered. The apertures in the VMAT plan are defined using the MLC. We investigated two methods of changing VMAT apertures for …
-
Uma abordagem multiobjetivo para o problema da realização da radioterapia de intensidade modulada
… sequence of configurations for a device (called multileaf collimator) which correctly delivers the prescribe doses to the patient. A common model for this problem is the decomposition of a matrix in a weighted sum of (0-1)-matrices, called segments, whose rows only have consecutive ones. Each …
-
Generation and application of Monte Carlo calculated beamlet dose distributions in radiation therapy
… are used to derive corrections to particular Multileaf Collimator (MLC) leaf sequences of IMRT treatment plans that have been miscalculated by a convolution-based dose calculation algorithm. These calculation inaccuracies (up to as much as 15%) arise due to the well known fact that …
-
Assessment of Collimator Jaw Optimization In Reducing Normal Tissue Irradiation With Intensity Modulated Radiation Therapy
… on the Varian 2100 platform by tracking the multileaf collimator (MLC) apertures with the accelerator jaws. Methods: Clinical radiation treatment plans for 10 thoracic, 3 pediatric and 3 head and neck patients were converted to plans with the jaws tracking each segment’s MLC apertures. Each …
-
Four-Dimensional MVCT Imaging and Spatial Translation of Helical Tomotherapy Dose Distributions Using Sinogram Modification
… along a pattern of motion and the multi-leaf collimator (MLC) control sinogram is used to translate dose distributions in space. A temporal re-binning algorithm was written that divided the MVCT sinogram projections into positional bins that were subsequently used to produce new sinograms for …
-
Dose verification of rotating collimator intensity modulated radiation thearpy
… (IMRT) has been proposed in which the entire multileaf collimator (MLC) is rotated between each segment. Current linear accelerators (linacs) are not designed for IMRT delivery with collimator rotation therefore extensive quality assurance testing must be done before this technique can be used …
-
Πολυπαραγοντική μελέτη προστασίας του ιπποκάμπου κατά την προφυλακτική ολοκρανιακή ακτινοβόληση ασθενών με μικροκυτταρικό καρκίνο του πνεύμονα
… Axesse) with different radiation field sizes and multileaf collimator (MLC) leaf thickness characteristics. The prescribed dose was 25 Gy in 10 fractions. Hippocampal dose constraints were calculated based on the Radiation Therapy Oncology Group 0933 (RTOG 0933) guidelines. Planning and treatment …
-
Forward and Inverse Treatment Planning Solutions for Small Animal Radiation Research
… dose painting method using a motorized variable collimator (MVC), which is a compromise between the multileaf collimator (MLC) available in most human clinical systems and the size limitations of small animal radiotherapy systems. The second contribution is a fast 3D inverse planning framework …