Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 33 for “"Multimeter"”.
-
Elektroninės grandinės - "Lambda diodo" tyrimas ir heterodininis taikymas /
… one is n- channel another p- channel. Using multimeter and DC power source voltage-current characteristics were measured. "Lambda diode" harmonic signal generator creation by connecting LC circuit to "lambda diode" and research. "Lambda" diode generator was used in heterodyning process as …
-
Optimizing graphene oxide reduction via laser irradiation
… the finished product was determined by two probe multimeter resistance measurements, and carbon to oxygen ratios given by X-ray microanalysis.
-
Komunikace měřicích přístrojů s počítačem – návrh laboratorních experimentů
… měření byly Stejnosměrný zdroj Agilent E3631A, multimeter Agilent 34411A nebo osciloskop Tektronix TDS 1012 a generátor Agilent 33220A.
-
Magnetic augmented rotation system (MARS ) - properties and performance
… a light bulb, a voltage transformer, and digital multimeter to monitor current/voltage in real-time. Additionally, infrared imaging is utilized during charging the rechargeable battery to monitor changes in temperature.
-
Automated fiber optic measurements
… Reflectometer, the Photodyne 22XLA Fiber Optic Multimeter and the 2275XQ Test Set. These devices were integrated through the General Purpose Interface Bus (GPIB) and software was developed to control the operation of the system. The system is capable of measuring many fiber parameters such as …
-
Μη καταστροφική μέτρηση καμπτικών συχνοτήτων ταλάντωσης για την ανίχνευση ρωγμών σε μεταλλικές, πλαστικές και τσιμεντένιες δοκούς με τη χρήση μαγνητοελαστικών αισθητήρων σε μορφή μικροσύρματος και κορδέλας
… at various depths. A detection coil and a multimeter were added to the setup. Thus, when the oscillator operated, it excited (forced) the beam at specific frequencies, and when resonance occurred, the sensor generated an EMF, which was detected by the multimeter. In this way, all the …
-
Resistivity measurement by eddy current methods for real-time monitoring of age hardening in heat treatable alloys
… V sub BCA, which is continuously measured by a multimeter. Also, calibration procedures were developed to allow conversion of the values of delta V sub BCA to a resistivity difference, Delta p=Ptest - Pref, between the test and reference samples. These calibration curves were generated by …
-
Investigation of CoO ATO for Solar Cells and Infrared Sheaths
… using a short circuit current- Voltage (J-V) and multimeter measurements.
-
Konzepte der internetbasierten Gerätesteuerung
… z.B. einem Schalter, einem Heizungsmodul, einem Multimeter bis hin zu virtuellen Geräten erfolgreich verifiziert.
-
The design, construction and tests of an in situ capacitance moisture sensor and a portable capacitance moisture meter for organic soil and sawdust
… 2.0 x3.0 xO.6 cm sensor and a hand-held digital multimeter with a capacitance range. The sensitivity of this moisture meter was compared to that of a commercially available fibreglass resistance type. In a series of experiments, two sensors (one of the capacitance type and one of the fiberglass …
-
Kompozitų su anglies nanovamzdeliais žemo dažnio triukšmo charakteristikos /
… included measuring resistance using digital multimeter and analyzer, and assessing noise charactersitics using a well-shielded laboratory setup to minimize external interference. Measurements of resistence and low frequency (10 Hz – 20 kHz) electric noise voltage fluctuations were conducted …
-
Effects of Proton Irradiation on the Mechanical and Physical Properties of Carbon Nanotube Based Composites
… resistivity was measured using a high resolution multimeter. Finally the influence of the irradiation on the mechanical properties, such as the elastic modulus and hardness, was probed using instrumented nanoindentation tests. The proton stopping power of the epoxy was shown to be unchanged by the …
-
3D printed polymer graphene nanocomposites for bio-sensor applications
… the resistance could be detected on a standard multimeter. In TPU, 1.5 wt. % GNP loading optimised phase separation and order; however, more importantly, the ductility properties of the TPU were not affected by the presence of GNPs. In PA11, an electrical percolation threshold was achieved at …
-
Development of Arduino-based portable systems for electroanalytical detection
… electrodes (ISEs). To avoid the use of a multimeter, an extended-gate metal-oxide-semiconductor field-effect transistor (MOSFET) is applied to the readout circuit and integrated with an Arduino microcontroller board. ALD1106 matched MOSFET pair is chosen for differential sensing to …
-
Development of a fast and simplified model of HVdc converter in PSCAD and performance comparison with LCC configurations
… measurement of the dc current using the existing multimeter in PSCAD. A dc voltage source is customized for the dc side of the converter, while the ac side is modelled as an ac current injected source. The new model can be utilized in place of the LCCs (either on inverter or rectifier sides of …
-
Carbon Nanotube (CNT) Coated E-glass Fibre Sensor for Structural Health Monitoring of Composite Materials
… differential resistances measured by a multimeter, both at the same specified tensile loading conditions. With two sets of data, the experimental resistance data was calibrated with the actual strain data collected. Ultimately, the experimental sensors created a sample of gauge factors …
-
Development and evaluation of a portable automatic test system for clinical use
… on a digital interface loop. A general purpose multimeter and special interface device were also connected to the loop. Dedicated test interface devices and complete software programs were developed for testing a Travenol Model BW-5 blood warmer and a IMED Model 960 infusion pump. In addition, …
-
Evaluating dissolved organic matter loads in tropical alpine rivers using FDOM measurements
… equipped with a CDOM/FDOM sensor and a portable multimeter, 38 on-site measurements of FDOM, pH and turbidity were completed. Simultaneously 38 samples were taken to be analyzed with fluorescence spectroscopy followed by parallel factor analysis. FDOM results performances were compared with …
-
A Cost-Effective, Noninvasive Dual Impedance-Based Wearable for Continuous Monitoring of Cardiovascular Health: Development of the Analog Front-End
… by comparing the system’s output with a multimeter. Calibration curves were then obtained and utilized for converting the system’s output to the standard impedance unit: ohms. Lastly, after validating the calibration approach, an in vivo study was conducted to obtain the HR, PTT, basal …
-
Simple and inexpensive biosensors for point-of-care diagnostics
… of an electroactive redox couple, and a digital multimeter to transduce the result of the assay. Adenosine is quantitatively determined using this device with a detection limit of 11.8 uM. The method for measuring HbA1c concentration, hemoglobin concentration, and thus %HbA1c in human blood is …
Page 1 of 2