Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 7 of 7 for “"Multiple Spin Echo"”.

  1. New techniques in nuclear magnetic resonance

    … strong radiofrequency pulses on the nuclear spin system is examined. Providing the durations of the pulses are short with respect to coupling constants within the spin system, they may be described by simple rotation operators which are exponential functions of the angular momentum operators. …

    oxford Repository record for New techniques in nuclear magnetic resonance (opens in a new tab)

  2. Human cardiac 31p magnetic resonance spectroscopy at 7 tesla

    … in the heart. A ‘short’ (6.5 minute) uttra-short echo chemical shift imaging (UTE-CSI) protocol is also established that is both sufficiently short and reproducible to allow multiple 7 T 31P-MRS spectra to be acquired in the same scanning session. This ‘short’ UTE-CSI scan is used in a …

    oxford Repository record for Human cardiac 31p magnetic resonance spectroscopy at 7 tesla (opens in a new tab)

  3. Development of Pure Shift NMR Spectroscopy Techniques Through Novel Acquisition Schemes

    … techniques cause losses in sensitivity. The MSE (Multiple Spin Echo) pure shift methodology in this thesis provides a sensitivity increase of around 10% for pure shift spectra acquired using the “Zangger Sterk” refocussing technique, though this varies substantially based on experimental …

    bristol Repository record for Development of Pure Shift NMR Spectroscopy Techniques Through Novel Acquisition Schemes (opens in a new tab) Download PDF for Development of Pure Shift NMR Spectroscopy Techniques Through Novel Acquisition Schemes (opens in a new tab)

  4. Pathological and Biomedical Characteristics of Spinal Cord Injury Determined Using Diffusion Tensor Imaging

    Traumatic spinal cord injury: SCI) is the most devastating injury that often causes the victim permanent paralysis and undergo a lifetime of therapy and care. It is caused by a mechanical impact that ultimately causes pathophysiological consequences which at this moment in time are an unresolved …

    wustl Repository record for Pathological and Biomedical Characteristics of Spinal Cord Injury Determined Using Diffusion Tensor Imaging (opens in a new tab)

  5. Nuclear Magnetic Resonance Imaging of Fluid Displacements in Porous Media

    … techniques: T1- weighted, inversion single-spin-echo NMR technique and Carr-Purcell-MeiboomGill (CPMG) multiple-spin-echo NMR technique have been successfully implemented. The inversion spin-echo technique distinguishes the water signal from the oil signal via the difference in longitudinal …

    texas Repository record for Nuclear Magnetic Resonance Imaging of Fluid Displacements in Porous Media (opens in a new tab) Restricted access

  6. Sensitivity enhancement and field-dependent relaxation in singlet nuclear magnetic resonance

    … antisymmetric quantum states of coupled pairs of spin-1/2 nuclei with zero total nuclear spin quantum number. These states are nonmagnetic and immune to exchange-symmetric relaxation processes such as intramolecular direct dipolar relaxation. Their lifetimes may be up to an order of magnitude …

    soton Download PDF for Sensitivity enhancement and field-dependent relaxation in singlet nuclear magnetic resonance (opens in a new tab)

  7. Three-dimensional dosimetry around small distributed high-Z materials

    … and the dose was quantified using MRI with a multiple spin echo technique for the measurement of the spin-spin relaxation rate (R2). The measured dose data were compared to theoretical data obtained from Monte Carlo experiments. The dose profiles around the foils from the PGD were in agreement …

    umn Repository record for Three-dimensional dosimetry around small distributed high-Z materials (opens in a new tab)