Results 1 to 20 of 193 for “"Multiple reaction monitoring"”
-
Analysis of urinary lipid biomarker candidates from tuberculosis patients by multiple reaction monitoring
… discovery of biomarker candidates, and targeted multiple reaction monitoring (MRM) is the method of choice for subsequent validation of biomarker candidates. A list of candidate urinary biomarkers has previously been generated which can discriminate between latent and active TB infection using …
-
Quantification of the PD-1/PD-L1 Axis in Various Cancer Types by Immuno-Multiple Reaction Monitoring
… antibodies, liquid chromatography, and multiple reaction monitoring to quantify PD-L1, PD-1, PD-L2, NT5E, LCK and ZAP70. Despite challenges posed by low protein concentrations in the PD-1/PD-L1 axis, mass spectrometry-based assays hold promise in overcoming the limitations of …
-
ΑΝΑΠΤΥΞΗ ΕΦΑΡΜΟΓΩΝ LC-MS/MS (MRM – MULTIPLE REACTION MONITORING) ΜΕΘΟΔΟΛΟΓΙΩΝ ΣΕ ΔΕΙΓΜΑΤΑ ΠΛΑΣΜΑΤΟΣ ΓΙΑ ΤΗΝ ΠΡΟΒΛΕΨΗ ΚΑΡΔΙΑΓΓΕΙΑΚΩΝ ΝΟΣΗΜΑΤΩΝ
ΣΚΟΠΟΣ: Τα καρδιαγγειακά νοσήματα αποτελούν την κύρια αιτία θανάτου παγκοσμίως. Για τον λόγο αυτό, υπάρχει κλινική ανάγκη για μια προγνωστική μέθοδο με αυξημένη ακρίβεια και ευαισθησία. Στόχος της παρούσας εργασίας είναι η εφαρμογή της τεχνικής LC-MS/MS (MRM) για την ανάπτυξη μεθοδολογιών για τη …
-
Ανάπτυξη LC-MS/MS (MRM-Multiple Reaction Monitoring) μεθοδολογιών σε δείγματα πλάσματος για την πρόβλεψη της εξέλιξης της Χρόνιας Νεφρικής Νόσου (ΧΝΝ)
Η Χρόνια Νεφρική Νόσος (ΧΝΝ) αποτελεί ένα μείζον πρόβλημα της δημόσιας υγείας. Η διάγνωση της ΧΝΝ βασίζεται σήμερα στην ανίχνευση της μείωσης του εκτιμώμενου ρυθμού σπειραματικής διήθησης (eGFR) και/ή της παρουσίας αλβουμινουρίας. Ωστόσο, αυτοί οι δείκτες έχουν σοβαρούς περιορισμούς στην αξιολόγηση …
-
Bridging the gap between molecular genetics and proteins in precision oncology: development of an immuno-multiple reaction monitoring assay for the PD-1/PD-L1 axis and validation in non-small cell lung carcinoma
… PD-L1 immunohistochemistry (IHC), faces multiple challenges. The lack of standardization across different assays complicates interpretation and PD-L1 IHC has also been shown to be vulnerable to interferences from post-translational modifications (PTM) such as glycosylation. Furthermore, …
-
Development of a multiple reaction monitoring liquid chromatography tandem mass spectrometry method for the simultaneous determination of five antiretroviral drugs in human blood plasma-a contrast of extraction efficiencies using selected sample preparation techniques
A multiple reaction monitoring liquid chromatography - tandem mass spectrometry (MRM LC-MS/MS) method for the simultaneous determination of antiretroviral drugs (Emtricitabine, Tenofovir, Efavirenz, Lopinavir and Retonavir) in sterilized human blood plasma was developed for therapeutic drug …
-
Analysis Strategies for Bioactive, Polar Fatty Amides in Complex Samples
… assignments pertaining to method development of multiple reaction monitoring detection of these species. Chromatographic separation methods of fatty acyls, with a focus on primary fatty acid amides and N-acyl glycines, are outlined in chapter 3 and these results are used to develop a two …
-
Investigating and detecting biomarkers for oxidative stress
… no prior knowledge of the modification sites. A multiple reaction monitoring method was developed from the MSMS analysis of in vitro chemical modification of human serum albumin and plasma samples. Observations from the MSMS analysis were employed to write the multiple reaction monitoring method …
-
Monitoring complex reactions using tandem mass spectrometric methods
… product ion scan, neutral loss scan (NLS) and multiple reaction monitoring (MRM) MS/MS methods were applied. Tetrakistriphenylphosphine palladium(0) was the catalyst of this reaction and a positively charged phosphonium aryl iodide tag (m/z 478) was implemented into the first catalytic cycle, …
-
Ανάπτυξη και επικύρωση μεθόδου με υγρή χρωματογραφία υπερυψηλής απόδοσης συζευγμένη με φασματομετρία μαζών (uplc ms/ms) για τον ταυτόχρονο προσδιορισμό φυτοπροστατευτικών προϊόντων σε πόσιμο νερό
… ιόντα (παρακολούθηση προεπιλεγμένων ιόντων- Multiple Reaction Monitoring-MRM). Για την προσυγκέντρωση των φυτοπροστατευτικών προϊόντων στο νερό εφαρμόστηκε η εκχύλιση στερεάς φάσης. Εφαρμόστηκε μία νέα μέθοδος διεξαγωγής πειραμάτων, γνωστή ως πειραματικός σχεδιασμός (experimental design ή …
-
Optimering av en gaskromatografisk tandem-masspektrometrisk metabolomikmetod för cerebrospinalvästska med tillämpning relaterat till Alzheimers sjukdom
… parallellt med fullt skanningsläge. För att Multiple Reaction Monitoring MRM skulle kunna användas var parametrar tvungna att optimeras från de standarderna som sedan skulle analyseras i provet. Standarderna som optimerades var ett urval metaboliter till en metod relaterat till diabetes samt …
-
Achieving the standard for the analytical scope and sensitivity of forensic toxicology urine testing in drug facilitated crime investigations via laminar flow tandem mass spectrometry
… in simultaneous positive and negative mode. Multiple reaction monitoring allowed quantification of analytes along with stable isotope internal standards. Validation parameters assessed included linearity, bias, precision, limit of detection, lower limit of quantitation, interference, and ion …
-
Library search-based drug analysis in forensic toxicology by liquid chromatography-mass spectrometry
… MS analysis, including a screening step based on monitoring of protonated molecules and a confirmation step based on LC–MS/MS product ion spectra. A method for simultaneous screening and quantitation of 18 antihistamine drugs in blood involved multiple-reaction monitoring (MRM) for screening and …
-
Nano- and Microplastics in Muscle Tissue of Top Predators of the Ocean
… chromatography mass spectrometry (PyGCMS) with multiple reaction monitoring. Results showed plastic concentrations ranging from 0-19081 µg gdw-1 in mature species with variations between size classes. All four species contained the greatest concentrations of plastics in the large size classes. …
-
LUPIN PROTEINS AS FOOD INGREDIENTS: DEVELOPMENT AND OPTIMIZATION OF LABEL-FREE METHODS FOR THE QUANTITATIVE ANALYSIS IN MASS SPECTROMETRY
… method was develop and applied to TPE. The Multiple Reaction Monitoring (MRM) label-free absolute quantitative method, based on the “standard addition” strategy was developed with the target to absolutely quantify the lupin target protein, i.e. gamma-conglutin, in the flour of white lupin. …
-
Comprehensive proteomic profiling of clinically relevant strains of Mycobacterium tuberculosis
… candidate proteins to use in the design of multiple reaction monitoring (MRM) MS experiments for targeted biomarker validation in patient derived biological samples such as sputum. Liquid chromatography mass spectrometry (LC MS/MS) and data capture were carried out using the LTQ Orbitrap …
-
LC-MS/MS determination of various drugs of abuse and metabolites in municipal wastewater effluent samples
… ionization was used along with dynamic multiple reaction monitoring (MRM) tandem mass spectrometry for identification and quantitation. The extraction method was validated with matrix matched spiked samples at the limits of quantitation (0.5 ng/mL to 30 ng/mL) for each analyte with …
-
Quantitative Approaches for Protein Differential Expression Analysis
… validation by targeted screening, i.e., multiple reaction monitoring (MRM). Preliminary experiments were performed to evaluate the performance of the spectral counting method. The method proved to be applicable for proteins with spectral counts≥2, and a close-to-linear relationship …
-
Development of an Analytical Method for VInca Alkaloids Using Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS)
… ionization (APCI) and three ions per analyte in multiple reaction monitoring (MRM) mode. Calibrators in methanol resulted in a LLOQ for vinblastine of approximately 0.77 ng/mL and of deacetylvinblastine at approximately 3.6 ng/mL. The LLOQ for plasma samples after SPE was 0.4450.047 for VBL and …
-
Multi-residue determination of b-agonists in bovine muscle using dispersive liquid liquid microextraction by +esi tandem mass spectrometry
… formic acid aqueous solutions as mobile phases, multiple reaction monitoring (MRM) scan mode was used. The seven beta-agonists were then simultaneous determined and identified in single analysis using 4000 Qtrap LC-MS/MS system. The DLLME method was validated using ISO 17025 and the EU criteria …
Page 1 of 10