Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 180 for “"Myoelectric"”.
-
Fractal analysis of myoelectric signals
In this thesis, we study fractal behavior of myoelectric signals (MESs). Mathematics and definitions behind fractal behavior is presented. Different methods of estimating the fractal dimension are discussed, including time domain-based methods (i.e. Katz method, Box-Counting method) and spectrum …
-
Myoelectric Human Computer Interaction Using Reliable Temporal Sequence-based Myoelectric Classification for Dynamic Hand Gestures
… design. What this dissertation focuses on is a myoelectric interface, which controls a device via neuromuscular electrical signals. Myoelectric interface has advanced by recognizing repeated patterns of the signal (pattern recognition-based myoelectric classification). However, when the …
-
Assessment of upper limb myoelectric prostheses
… a review of published literatures on upper limb myoelectric prostheses. The review focused on critical factors affecting successful prescriptions, current standards governing design and safe use, guidelines and practice for testing, performance evaluation, and outcome measurements. To understand …
-
Myoelectric signal recognition using genetic programming
This thesis presents a new method of myoelectric signal recognition. Myoelectric signals are electric signals generated by the motion of a person's muscle and can be used as control input for prosthetic hands. It uses genetic programming to create a set of equations capable of recognizing three …
-
Multi-scale analysis of myoelectric signals
… scales, known as multi-scale signals. The myoelectric signal, which is comprised of deterministic (i.e., structured) and random contributions, exhibits multi-scale characteristics. In this work, we present four major paradigms for multi-scale analysis of myoelectric signals; namely, …
-
Myoelectric control in a precision tracking task
… to perform a precision tracking task using the myoelectric output of the forearm. The tracking task was performed using both a conventional force stick and the electric output from the same muscle groups involved in operating the force stick. Multiple trials with both systems enabled a good …
-
Evaluation of a Novel Myoelectric Training Device
… giving rise to the importance of appropriate myoelectric control. EMG models in the past have assumed a linear proportionality to simplify the EMG-force relationships. However, it has been shown that a non-linear EMG-force relationship may be a more effective model. This study focused on …
-
Evaluation of a novel myoelectric training device
… shows that a patient’s success in using a myoelectric prosthetic arm is dependent on receiving effective training, current methods of training are not designed to effectively hold attention long enough for optimal training. This study focused on evaluating a novel myoelectric training …
-
Insights into experiences with myoelectric training and evaluation of a novel device: perspectives of clinicians in pediatric myoelectric rehabilitation
… by emotional and social difficulties. While myoelectric prostheses offer independence, their complex control demands extensive training and mental effort. Pre-prosthetic training is crucial for effective use, yet the absence of extensive pre-prosthetic training is one of the main causes …
-
Myoelectric Control of a Robotic Exoskeleton for Rehabilitation
A primary challenge in the design of human-robot interfaces for rehabilitation after neurological injury, such as stroke or spinal cord injury, is the detection of user intent, needed to maximize the efficacy of the therapy. Common approaches to rehabilitation robot interfaces, including the …
-
Issues in myoelectric teleoperation of complex artificial hands
… anthropomorphic robotic hands: converting the myoelectric signal generated by an operator's muscles during movement into robot commands replicating the motion. This teleoperation scenario is, in a sense, the limiting case of myoelectric prosthetic hand control. This project contributes to …
-
Co-adaptive myoelectric control for upper limb prostheses
[ES] Mucha gente en el mundo se ve afectada por la pérdida de una extremidad (las predicciones estiman que en 2050 habrá más de 3 millones de personas afectadas únicamente en los Estados Unidos de América). A pesar de la continua mejora en las técnicas de amputación y la prostética, vivir sin una …
-
Synthesis of gastrointestinal contractile activity from myoelectric activity
… have been implanted intraoperatively to record myoelectric activity. The electrical control activity (ECA or slow waves), thus recorded, controls the maximum frequency and timing of contractions, whereas the electrical response activity (ERA or spike burst) is correlated with contractions. Our …
-
Improving the Robustness of Pattern Recognition-Based Myoelectric Prostheses
… to provide some relief to these individuals. Myoelectric prostheses have received significant attention in recent years as they have been designed to look more natural and provide the user with enhanced degrees of freedom (DoF) over the traditional body-powered prostheses. Myoelectric …
-
Factors Influencing Myoelectric Wearing Patterns of Pediatric Prosthetics Patients
… amputees, including passive, cable-operated, and myoelectric arms, but the myoelectric appears to be the most popular choice of children and their families. However, there is growing concern among clinicians that, despite its advanced technological capabilities, the myoelectric prosthesis is …
-
Robust and reliable hand gesture recognition for myoelectric control
… (MCI), systems are controlled by transforming myoelectric signals into interaction commands that convey the intent of user movement, mostly for rehabilitation purposes. Taking the myoeletric hand prosthetic control as an example, using sEMG recorded from the remaining muscles of the stump can …
-
Surface myoelectric signal analysis and enhancement for improved prosthesis control
… techniques are presented in the field of myoelectric control. Specifically, algorithms for activity detection, noise identification and noise reduction are introduced, evaluated and discussed. The ultimate aim has been to develop algorithms to improve the performance of prosthetic control …
-
POWER SPECTRAL ANALYSIS OF SURFACE MYOELECTRIC SIGNALS DURING DYNAMIC CONTRACTIONS
The stochastic nature of surface myoelectric signals (MES) requires the use of power spectral analysis for effective characterisation. Spectral changes during different types of muscular activity are monitored using spectral parameters like mean power frequency, ratios of powers in several …
Page 1 of 9