Hydrogen induced damage in pipeline steels
… charging was also compared to the industrial standard test for HIC, the NACE standard TM0284. The electrolytic charging (EC) apparatus was designed to optimize the reproducibility of the HIC results and the robustness of the components during long charging times. A characterization study on …
-
Evaluation of HIC Resistance in Two X70 Pipeline Steels Using Ultrasonic Testing
… of 2.5 and about 0.5, respectively. Using the NACE standard TM0284-2016 and solution C, samples were tested at pH levels of 2.7 and 5.5 for test periods of 1 to 64 days. Cracking was then evaluated using ultrasonic techniques. At a pH of 2.7, both steels showed cracking after one day in test …