Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 89 for “"NBCC"”.
-
Burning Up: Fire Safety Barriers to Low Embodied Carbon Housing in the NBCC
The National Building Code of Canada (NBCC) emerged in response to, and developed from, catastrophic conflagrations throughout history which demanded the need for consistent construction and fire safety standards for buildings across the country. While fire safety remains an essential consideration …
-
Seismic design and performance of steel moment resisting frame buildings designed using NBCC 2005
… Although the National Building Code of Canada (NBCC 2005) is not yet a fully performance-based code, it presents an objective-based format which incorporates some concepts of the performance-based design. It provides a force-based seismic design approach, where the displacement capacities are …
-
A study of the implications of soil-structure interaction effects on the seismic response of high-rise reinforced concrete buildings
… in the quantification of site effects in the NBCC (National Building Code of Canada) since the introduction of the foundation factor (F) in 1965, recent parametric studies have shown the 1990 NBCC provisions for site effects to be inadequate. In addition, soil-structure interaction effects are …
-
Seismic retrofit of existing reinforced concrete moment resisting frame structures using diagonal prestressing
The national building code of Canada (NBCC) has been under constant evolution since its first issue in 1941. Over the years, knowledge related to structural engineering and more specifically seismic response has continued to evolve through research and field investigations. Recently, the 2005 NBCC …
-
Experimental Investigation of Tornado-Induced Pressures on Low-Rise Buildings
… pressure coefficients were then compared to the NBCC 2015 code to clarify if there were any limitations of the current wind design criteria. It was found that the building orientation did not have a significant effect on pressure coefficient trends and magnitudes on the walls and roofs. For the …
-
Seismic design and performance evaluation of balloon-type CLT shear walls in Canada
… CSA O86 or the National Building Code of Canada (NBCC). This thesis proposes a seismic design procedure for balloon-type CLT shear walls using the Equivalent Static Force Procedure (ESFP) in NBCC. An equation to calculate the moment capacity of a wall has been developed as part of the procedure. …
-
Safety Analysis of a Historical Structure: Turner Valley Gas Plant - Absorption Building
… respect to the National Building Code of Canada (NBCC) and the Standards and Guidelines for the Conservation of Historic Places (SGCHP) [7] [4]. The building is located at the Turner Valley Gas Plant (TVGP) National Historic site [8]. The TVGP was Alberta’s first natural gas plant built and thus …
-
2-D non-linear seismic analysis of one-storey eccentric precast concrete buildings
… shear walls. To check the effectiveness of the NBCC code design, computer studies have been made on a box-type building statically designed for different eccentricities. The strength of the shear walls was calculated assuming that each panel was a cantilever fixed at the base with dowel bars …
-
Challenges Faced in Application of Fire and Life Safety Design in Current Canadian Building Code
… based on the National Building Code of Canada (NBCC). The current version of NBCC is an objective-based building code which allow code users to substitute prescribed building designs with a solution achieving the same level of performance defined by intent statements. These intent statements …
-
Development of a Value-Based Design (VBD) Framework for Seismic Design of Buildings
… by the National Building Code of Canada (NBCC 2020), primarily focuses on life safety. However, the code gives limited attention to post-earthquake functionality and the long-term economic consequences. This study presents a Value-Based Design (VBD) framework for buildings subjected to …
-
Wind Loads On Non-Rectangular Flat-Roof Buildings: Design Provisions And Application Of Machine Learning
… with the design provisions and guidelines of NBCC 2020 and ASCE/SEI 7-22, 2022 for rectangular buildings. The comparison with NBCC 2020 indicated that roof design provisions are comparable to the experimental results in the corner zone and lower than the experimental peaks in the edge and …
-
Out-of-plane seismic performance of unreinforced clay brick masonry walls
… of the 2005 National Building Code of Canada (NBCC) level for Vancouver, but exhibited a stable rocking behaviour without collapse beyond a ground motion 1.5 times the 2005 NBCC level. Simple analytical methods were used to calculate the un-cracked wall stiffness, maximum force on an un-cracked …
-
A Proposal of Design Spectrum Based on Uniform Hazard Spectral Format Using 4th Generation Seismic Hazard Maps of Canada for CHBDC
… edition similar to its building counterpart (NBCC 2005). In fact the code writers expressed such intentions with comments in the commentary of CHBCD 2006 as “New methods for defining ground motion (e.g., uniform hazard spectra) are being investigated for possible inclusion in future codes.” …
-
Comparative design of reinforced concrete shear walls.
… details provided to the shear walls. The NBCC-1995 and the IBC-2000 design code procedures were used to determine the earthquake design loads in Chapter 2, and the ACI318-99, the CSA-1995 and the NZS-1995 were used to design a reinforced concrete shear wall in Chapter 3. Comparative …
-
Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls
… by the National Building Code of Canada (NBCC). The fragility assessment study further indicated that similar walls are expected to conform to the current drift limits of the NBCC even at high seismic regions in Canada. The results of this study are expected to contribute to the growing …
-
Seismic performance evaluation of reinforced concrete moment resisting frames
… edition of the National Building Code of Canada (NBCC 2005) requires the use of dynamic analysis for the seismic design, except in the case of short to medium height simple buildings with regular geometry where the use of the equivalent static load method is still allowed. In this study, three …
-
An Improved Static Seismic Design Method for Podium Structures with Vertical Irregularity of Mass and Stiffness
… loads appropriate to such as structure, both for NBCC 2010 (National Research Council of Canada (NRCC), 2010). and ASCE 7-10 (American Society of Civil Engineers (ASCE), 2010). Based on the work of Yuan & Xu, the current study aims to both improve the ease of use and the scope of these methods. …
-
Nonlinear behaviour of coupled shear walls strengthened with externally bonded carbon fibre reinforced polymer composite under seismic loadings
… to old National Building Code of Canada (NBCC) before 1970s, and two CSWs designed according to new design code (NBCC 2015) and Standard (CSA A23.3-14) located in Montreal and Vancouver as representative of East and West of Canada, respectively. Nonlinear dynamic analyses using RUAUMOKO …
-
Seismic Fragility Assessment of Pre- and Post-Retrofit 1980s Concentrically Braced Frame Office Buildings in Moderate Seismic Zones
… 1980, both the National Building code of Canada (NBCC) and Steel design standard (CSA/S16) have continually evolved, while lower interest was allocated in the development of guidelines for seismic assessment and retrofit of existing buildings located in seismic zones. This study focuses on the …
Page 1 of 5