Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 29 for “"NIOSH Method"”.
-
A Test of an Alternate Calibration Matrix for NIOSH Method 7300
… filters prepared and analyzed according to N:OSH Method 7300, differ significantly, from those obtained when the instrument is calibrated using EPA Method 200.7 acid matrix standards. The null hypothesis was that no statistically significant difference, measured at the 95% confidence level, would …
-
Capillary Zone Electrophoresis Analysis of Isocyanates in Spray-Painting Operations
… exposed to a spray-painting environment. Several methods were used for the sampling and analysis of airborne 1,6- hexamethylene diisocyanate (HDI) monomer and polyisocyanate during Spray-painting operations. NIOSH Method 5521, OSHA Method 42, NIOSH Method 5522 and Capillary Zone Electrophoresis …
-
Diesel particulate matter and polynuclear aromatic hydrocarbon exposure of diesel vehicle operators in small to medium sized underground coal mines
… Institute for Occupational Safety and Health (NIOSH) method 5040 was used to measure exposure for DPM using submicron elemental carbon as surrogate. NIOSH method 5515 was used to measure exposure towards seventeen PAH compounds. Exposure results for DPM were far below the available exposure …
-
Validation of Passive Air Sampling Monitors Onboard United States Navy Submarines
… compared to more traditional active air sampling methods when sampling for acrolein, formaldehyde and ozone in the enclosed submarine atmosphere. Acrolein monitors containing 2-hydroxymethylpiperidine (HMP) impregnated glass fibers and 2-HMP silica gel as sorbent media, formaldehyde monitors …
-
Crystalline silica exposure in platinum mining : a task based approach
… the differences in protocols used by the mine to NIOSH method 7602. Methods: Dust sampling was conducted by means of two cyclone samplers (aspirated at 2.2 L/min) in the breathing zone of each of the 48 workers in 4 different areas. Two cyclone samplers were used to compare two different …
-
Collection efficiencies of airpurifying respirators containing electrostatic filter media
… resistance to the wearer. The certification method used by National Institute for Occupational Safety and Health (NIOSH) is considered to represent worse case respirator performance. Respirator certification does not consider either the mechanism of particle capture or the type of filter …
-
Evaluation of thermal desorption as an alternative technique for the measurement of coal tar pitch volatiles
… of a thermal desorption (TD) technique based method as an alternative method to be used for the measurement of the concentration of CTPVs in ambient air by assessing it along criteria such as ease of use, cost, accuracy and precision by comparing it to NIOSH's Method 5515 and OSHA's Method 58 …
-
Hydrogen Fluoride Method Development For The OgawaTM Passive Sampling Device
… (HF). The project was initiated to develop a method to verify compliance with emissions regulations for Coronet. Field and laboratory trials were conducted. Mixed cellulose ester filters were saturated with 70% TEA and placed in the PSDs. Aermod ISCT3 modeled ambient HF concentrations at …
-
New Sampling and Analysis Method for Isocyanates in Spray-Painting Operations
… Institute for Occupational Safety and Health (NIOSH) has already set the Recommended Exposure Limit for several diisocyanate monomers. The measurement of isocyanates in air is a challenging sampling and analytical problem for several reasons. Isocyanates can exist in air as vapor, or as aerosol …
-
The Relationship Between Molten Iron Chemistry Of A Cupola Furnace And Airborne Contaminants
… Institude for Occupational Safety and Health (NIOSH) Method 7303, most of which were metals. The concentrations of 13 out of 21 elements and compounds were compared to the corresponding elements in molten metal/iron stream analyzed in house by the company. While the results showed a complex …
-
Niveles de exposición ambiental a polvo de carbón y su relación con las condiciones de higiene y seguridad industrial en trabajadores de minas subterráneas de la región de Boyacá
… mines in the region of Boyacá. Materials and methods: Cross-sectional study, where questionnaires were used to collect data on working conditions and there was collected environmental sampling of particulate matter by means of gravimetric analysis and methodology 0600 of NIOSH method out. …
-
Dermal and respiratory exposure to nickel in a packaging section of a base metal refinery
… may come into contact with were also assessed. Method: Respiratory and dermal exposure assessment was done concurrently. Respiratory exposure was assessed and analysed by using the National Institute for Occupational Safety and Health (NIOSH) method 7300. The Institute of Occupational Medicine …
-
Mελέτη χημικής σύστασης σωματιδιακής ύλης PM10 - PM2.5 σε δύο περιοχές της Αθήνας
… με τη θερμική/οπτική μέθοδο ανάλυσης (NIOSH Method 5040) των φίλτρων δειγματοληψίας, χρησιμοποιώντας τον αναλυτή Thermal/Optical Carbon Aerosol Analyzer, (Sunset Laboratory). Για την ανάλυση των κατιόντων ( ΝΗ4+, Na+, K+, Mg2+ and Ca2+) χρησιμοποιήθηκε ο ιοντικός χρωματογράφος (Ion …
-
Measurement of Community and Laboratory-Generated Airborne Particulates Using a New Sampling Method
… of the sampled particles through traditional NIOSH methods, and using a new, real-time instrument known as the EPAM 5000. Data from the EPAM and NIOSH methods were compared to the EPA's particulate matter standards and the OSHA permissible exposure limits for total and respirable dust. Dust …
-
A versatile low-cost platform for particulate matter, volatile organic compound, and noise monitoring
… objectives associated with reference-grade methods. We developed a platform based on the AirPen, a low-cost monitor for assessing personal exposure to particulate matter and volatile organic compounds. Variations of the platform with different form factors, sensors, and sampling media …
-
Application of Fourier-transformed-infrared spectroscopy to quantitate amorphous silica in personal air samples in sugarcane cutters
… compared to the currently accepted NIOSH method (e.g., X-ray diffraction). The model was created, and initial concentrations of amorphous silica were determined. During the analysis of samples, the need to ascertain the detection limit of the FTIR method was evident. This project, …
-
Evaluation of 1-Nitropyrene as a Surrogate Measure for Diesel Exhaust: Assessment of Personal Air Monitoring Data from an Underground Mine
… and used to form a predictive model for 1-NP. Methods Personal exposure data were collected on a cohort of 20 employees at a large underground metal mine during 4 different sample campaigns. Full-shift personal sampling was conducted using an MSHA compliant SKC DPM impactor downstream of a GS-1 …
-
Assessment of dermal exposure and skin condition of refinery workers exposed to selected metals
… to different dermal exposure assessment methods; (ii) to assess dermal exposure of refinery workers to nickel and/or cobalt by making use of skin wipes as a removal method; (iii) to assess concurrently the skin condition of the above mentioned workers by measuring skin hydration, …
-
Dermal exposure and skin barrier function of workers exposed to copper sulphate at a chemical industry
… influence the permeation of chemical substances. Methods: The change in skin barrier function of reactor workers, crystal and powder packaging workers at the chemical industry were assessed by measuring their dominant hand's palm, back and wrist as well as their foreheads' skin hydration, …
-
Exposure to silica during the production of titanium dioxide from beach sand
… by means of X-ray diffraction based on NIOSH method 7500. Silica quartz was detected in personal respirable dust samples and bulk dust samples obtained from the mining and production plants, but amorphous silica was only detected in three personal exposure samples at the Slag plant and …
Page 1 of 2