Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 53 for “"National Building Code of Canada (NBCC)"”

  1. Dynamic response of moment-resisting steel frames

    The focus of this study is to determine if the current design provisions related to moment-resisting steel frames result in frames that behave in the manner anticipated by code writers and, more importantly, that respond satisfactorily during a real seismic event. Twelve steel moment-resisting …

    mcgill Repository record for Dynamic response of moment-resisting steel frames (opens in a new tab)

  2. Developing and Testing a Model of Site Amplification for Southern Ontario

    … shear-wave velocity in the top 30 metres of soil; VS30. Moreover, VS30 is not well correlated with site amplification in this region. This study develops a model that can better estimate ground motions and shaking intensities in southern Ontario based on readily-available information. The …

    uwo Repository record for Developing and Testing a Model of Site Amplification for Southern Ontario (opens in a new tab)

  3. Development of a design methodology for steel frame wood panel shear walls

    … main testing program as well as a summary of past wood frame and steel frame shear wall research. An extensive review of existing data interpretation methodologies is presented. The equivalent energy elastic-plastic (EEEP) technique is chosen as most suitable for the wall systems under …

    mcgill Repository record for Development of a design methodology for steel frame wood panel shear walls (opens in a new tab)

  4. Seismic drift demands of reinforced concrete buildings

    The main objective of the current research is to establish drift demands for reinforced concrete buildings designed on the basis of the National Building Code of Canada (NBCC-2005). A total of 12 reinforced concrete buildings with three different heights and structural systems, consisting of moment …

    ottawa-retro Repository record for Seismic drift demands of reinforced concrete buildings (opens in a new tab)

  5. Effects of scaling of earthquake excitations on dynamic response of reinforced concrete frame buildings

    The objective of this study was to evaluate the effects of various scaling techniques of real accelerograms on the response of medium height moment-resisting reinforced concrete frame buildings. Detailed inelastic time-history analyses were conducted on three reinforced concrete frame buildings. …

    ottawa-retro Repository record for Effects of scaling of earthquake excitations on dynamic response of reinforced concrete frame buildings (opens in a new tab)

  6. Review of the Resistance Factor for Steel

    The current resistance factor of 0.90 specified in CSA S16.1-94 “Limit States Design of Steel Structures” was reviewed for tension members failing by gross section yield or net section fracture, columns under concentric axial loads and laterally supported bending members. Large quantities of …

    uwo Repository record for Review of the Resistance Factor for Steel (opens in a new tab)

  7. Seismic evaluation and retrofit of a precast concrete structure

    … and is considered a post-disaster emergency building since it houses spare parts for municipal facilities. The warehouse was first evaluated through a visual inspection and identified as being seismically vulnerable. A series of three-dimensional models of the structure were analyzed to …

    mcgill Repository record for Seismic evaluation and retrofit of a precast concrete structure (opens in a new tab)

  8. Design of gravity-load frames for seismic deformation demands in highrise concrete buildings with shear walls in Canada

    A building can be divided into two main components: the seismic-force resisting system (SFRS), responsible for withstanding seismic forces, and the remaining structure, often referred to as the gravity-load resisting frame (GLRF). Although the GLRF is not designed to resist seismic forces directly, …

    ubc Repository record for Design of gravity-load frames for seismic deformation demands in highrise concrete buildings with shear walls in Canada (opens in a new tab)

  9. SCENARIO SHAKEMAPS FOR OTTAWA, CANADA

    … ranks third among Canadian urban areas in terms of seismic risk. Variability in near surface geology plays an important role in earthquake ground shaking in the region. Scenario ShakeMaps are generated for the Ottawa region to study the expected ground-shaking intensity distribution patterns, for …

    uwo Repository record for SCENARIO SHAKEMAPS FOR OTTAWA, CANADA (opens in a new tab)

  10. Seismic design and performance evaluation of balloon-type CLT shear walls in Canada

    In recent years, the popularity of mass timber buildings has increased in Canada and around the world. Among the types of mass timber elements that are being used to construct these buildings are cross-laminated timber (CLT) panels. This research explores the application of CLT panels as …

    ubc Repository record for Seismic design and performance evaluation of balloon-type CLT shear walls in Canada (opens in a new tab)

  11. Out-of-plane seismic performance of unreinforced clay brick masonry walls

    Given sufficient anchorage to the diaphragms, out-of-plane walls in unreinforced masonry buildings have been shown to crack above mid-height and rock as two rigid bodies. This study investigates the sensitivity of the rocking response to the type of ground motion and the quality of the wall …

    ubc Repository record for Out-of-plane seismic performance of unreinforced clay brick masonry walls (opens in a new tab)

  12. Fundamental period of vibration for reinforced concrete buildings.

    The fundamental period of vibration of buildings is one of the parameters that has a significant influence on the earthquake induced lateral forces. The fundamental period of vibration of reinforced concrete buildings measured during major earthquakes are collected and then compared with the …

    ottawa-retro Repository record for Fundamental period of vibration for reinforced concrete buildings. (opens in a new tab)

  13. Behaviour of bolted end-plate connections for glulam braces under cyclic axial loads

    … becoming a major structural system throughout Canada, and globally. Glulam braced frames are one of these mass timber structural systems that can be used in high seismic zones. Currently, the National Building Code of Canada (NBCC) provides ductility and overstrength factors for glulam braced …

    ubc Repository record for Behaviour of bolted end-plate connections for glulam braces under cyclic axial loads (opens in a new tab)

  14. Seismic design and performance of steel moment resisting frame buildings designed using NBCC 2005

    Currently the building code authorities in many jurisdictions including Canada feel that a performance-based design approach should be used to ensure that the structure has adequate strength and deformation capacities. Although the National Building Code of Canada (NBCC 2005) is not yet a fully …

    concordia

  15. Seismic performance evaluation of reinforced concrete moment resisting frames

    … last few decades, the concepts and procedures of seismic design of buildings have evolved significantly. Traditionally, seismic design was based on providing the structure with the strength it needs to resist equivalent lateral forces that represent the earthquake induced forces. This …

    concordia

  16. Estimation of Wind Hazard over Canada and Reliability-based Assignment of Design Wind Load

    The current National Building Code of Canada (NBCC) recommends a wind load factor of 1.4 and the nominal wind velocity pressure corresponding to 50-year return period value of the annual maximum hourly-mean wind speed, VAH. This study is focused on mapping wind hazard for Canada and on calibrating …

    uwo Repository record for Estimation of Wind Hazard over Canada and Reliability-based Assignment of Design Wind Load (opens in a new tab)

  17. Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls

    … (RM) shear walls. The test walls covers a range of design parameters to facilitate benchmarking, a thorough performance investigation, and calibration of numerical models as well as development of fragility curves within the context of Performance Based Seismic Design (PBSD). The details of the …

    mcmaster Repository record for Shake table Seismic Performance Assessment and Fragility Analysis of Lightly Reinforced Concrete Block Shear Walls (opens in a new tab)

  18. Seismic response of tall buildings using ground motions based on National Building Code Canada 2015

    The seismic analysis of tall buildings requires nonlinear analysis in order to determine their behaviour in a more realistic manner. Nonlinear analysis necessitates the input of suitable ground motions records that represent the hazard at the site of the building. Finding appropriate ground motions …

    ubc Repository record for Seismic response of tall buildings using ground motions based on National Building Code Canada 2015 (opens in a new tab)

  19. Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system

    Seismic torsional responses in buildings is a result of eccentricity in mass and stiffness distribution. Torsional irregularity is one of the major causes of severe damage and collapse of structures during an earthquake. In this study, effect of torsion on the structures is reviewed, the definition …

    ubc Repository record for Mitigating torsional irregularity using cross laminated timber-reinforced concrete hybrid system (opens in a new tab)

  20. Analytical studies of a 49-storey eccentric braced building

    The purpose of this research is to study the seismic behaviour of a well instrumented 49-storey steel frame building in San Francisco, California. The building was subjected to ground motions from the Loma Prieta earthquake (M[sub s] = 7.1) of October 17, 1989. During the earthquake the building …

    ubc Repository record for Analytical studies of a 49-storey eccentric braced building (opens in a new tab)

Page 1 of 3